evoheat H15A Installation And Instruction Manual Download Page 8

   2. The data of unit

Specification

Cooling working condition:(DB/WB)35℃/24℃, (Outlet/Inlet) 7℃/12℃.
Heating working condition: (DB/WB) 7℃/6℃.  (Outlet/Inlet) 35℃/30℃.

BS EN 14511-1-2013 Air conditioner, whole liquid cooling machine, electric compressor. 
Part2: Test condition Part3:Test method Part4:related requirements.

6

Model

Cooling Capacity

Heating Capacity

Electric Heating Power

Cooling Power Input  

Heating  Power Input

Operation Electric Current(cooling/heating)

Cooling Capacity Range

Heating Capacity Range

Cooling Power Input Range

Heating Power Input Range

Power Supply

Compressor Quantity

Compressor Model                             

Fan Quantity

Fan Power Input 

Fan Rotate  Speed

Noise

Water Pump Input

Max water head

Water Connection

Water Flow Volume

External Pressure

Unit Net Dimensions (L/W/H)

Unit Shipping Dimensions (L/W/H)

Net Weight                                        

Shipping Weight 

kW

BTU/h

kW

BTU/h

kW

kW

kW

A

kW

kW

kW

kW

W

RPM

dB(A)

kW

m

inch

3

m /h

m

mm

mm

kg

kg

 H15A

10

34000

15

51000

3.0

3.1

3.1

14.1/14.1

6.0

15.0

6.0

18.0

1.6

6.0

1.6

7.0

230V

/50Hz

1

Scrolll

2

110

×

2

850

58

0.18

12.5

1 1/4

2.5

10

1000*465*1475

1050*510*1500

See nameplate

See package label

H8A

7

23800

9

30600

3.0

2.6

2.6

11.8/11.8

2.0

10

2.5

11.5

1.0

3.4

0.8

3.4

230V

/50Hz

1

Rotary

1

110

850

54

0.18

12.5

1.6

10

980*465*900

1010*490*920

See nameplate

See package label

7

3    Unit dimension 

  

Specification

Models: H15  

 

A

1000

5

0

5

4

6

5

647

1

4

7

5

Water inlet 1 1/4

''

Condensate outlet 1 1/4''

Water outlet 3/4''

Water outlet 1 1/4''

Water

 

pump

 

wire

3

6

9

.5

1

7

0

266.5

51.5

7

Models:

H8A

Water outlet 1''

Water inlet 1

''

980

700

465 440

900

338

121

90

Summary of Contents for H15A

Page 1: ...Installation and Instruction Manual Inverter Air Source Water Heat Pump Floor heating and Air con Unit Hero Series Manual...

Page 2: ...f heat pump 2 Choose a right heat pump unit 3 Installation place 4 Installation method 5 Water loop connection 6 Power supply connection 7 Location of the unit 8 Transit 9 Trial Running 1 Interface 3...

Page 3: ...uded which is very easy for installation 3 Flexible installation The unit has smart structure with compact body just simple outdoor installation is needed This series of heat pump unit owns following...

Page 4: ...n Compulsory implement The listed action need to be taken ATTENTION include WARNING Please pay attention to what is indicated Mark Notes Icon notes WARNING ATTENTION To prevent the users and others fr...

Page 5: ...red When there is something wrong or strange smell the power supply need to be shut off to stop the unit Continue to run may cause electrical short or fire Move and repair Entrust Prohibit Entrust Whe...

Page 6: ...check the installation basement in a period one month to avoid any decline or damage on the basement which may hurt people or damage the unit Safety Precaution Meaning Fix the unit Installation Place...

Page 7: ...controller is 200 meters Air outlet in horizontal direction Water intlet tube Remote Controller Manually Water outlet tube 5 Air outlet in horizontal direction Water outlet tube Water intlet tube The...

Page 8: ...nge Power Supply Compressor Quantity Compressor Model Fan Quantity Fan Power Input Fan Rotate Speed Noise Water Pump Input Max water head Water Connection Water Flow Volume External Pressure Unit Net...

Page 9: ...ation Models H15A 1000 505 465 647 1475 Water inlet 1 1 4 Condensate outlet 1 1 4 Water outlet 3 4 Water outlet 1 1 4 Water pump wire 369 5 170 266 5 51 5 7 Models H8A Water outlet 1 Water inlet 1 980...

Page 10: ...e and high efficiency 2 Environmentally friendly refrigerant Use the new generation of environmentally friendly refrigerant R410 which is harmless to the ozone sphere 3 Heating in frigid environment O...

Page 11: ...ooling unit for cooling chilled water outlet temp at 5 15 maximum ambient temp at 43 For heating warm water inlet temp at 40 50 minimum ambient temp at 10 Unit application a s w h p is used for house...

Page 12: ...ank on the top point of the water loop and the water level in the tank must be at least 0 5 meter higher than the top point of the water loop 6 Power supply connection Open the front panel and open th...

Page 13: ...ller Check whether the water pump is running if it runs normally there will be 0 2 MPa on the water pressure meter When the water pump runs for 1 minutes the compressor will start Hear whether there i...

Page 14: ...In the state of cooling the icon Cool is on In the state of heating the icon Hot is on 5 Fan Speed Short press Fan Speed to enter the Query interface 6 7 8 In OFF state long press ON OFF to enter the...

Page 15: ...4 way valve status icon is on and when the 4 way valve shuts down the icon is off Inlet Inlet icon Compressor When the compressor starts up in the main display area thecompressor status icon is on and...

Page 16: ...In the main interface long press for 1 second to switch between the cooling and heating modes Cooling Interface Heating Interface Note 1 Without Thermostat wired controller can be used for Startup Shu...

Page 17: ...omatically record the setting and back to the main interface Note In the query parameter interface it cannot automatically back to the main interface 3 3 Temperature Short press or to enter thetempera...

Page 18: ...perature Outlet Temperature Suction Temperature Discharge Temperature Ambient Temperature Coil Temperature Low Pressure High Pressure Electronic Expansion Valve Steps Compressor Actual Frequency Compr...

Page 19: ...rt press for flashing by the minute Short press or to change flashing by the minute Short press back to the main interface 3 6 2 Set and cancel the timing if connected to the thermostat the timing fun...

Page 20: ...ON OFF back to the main interface and short press UP or DOWN to display multiple errors On the main interface short press ON OFF to back to the Error Interface For 10 seconds without operation automa...

Page 21: ...E03 E19 E20 E07 P81 E44 E21 E22 E23 blank 5 Electronic Control Error Table None DC bus over voltage protection DC bus low voltage protection IPM over current protection IPM overheating protection Radi...

Page 22: ...GND GND GND GND GND GND GND GND GND GND GND GND GND 5V 12V GND 485_B 485_A CAN_L GND 12V CAN_H 12V GND 485_B 485_A CN1 CN2 CN7 CN3 CN4 CN9 DI5_PWM DO5_PWM DI4_PWM DO4_PWM DI3_PWM DO3_PWM DI2_PWM A02 D...

Page 23: ...wer Live Wire Not Used Pump 4 way valve Fan Not Used Def Heating Crankshaft Heating Spray Valve Auxiliary Electric Heating Not Used Inlet Temperature Sensor Outlet Temperature Sensor Discharge Tempera...

Page 24: ...of power component is too high Fault of current sampling Compressor current is too high Input voltage is in default phase Default phase step out or hardware damage on actuator Fault of DSP and communi...

Page 25: ...er or capillary 3 lack of water flow 1 check the gas leakage and recharge freon 2 replace filter or capillary 3 clean the water filter and discharge the air in water loop Compressor do not run 1 power...

Page 26: ...other modules which are indispensable fittings are provided by users or installation company 2 The unit which of code contains the letter B has water pump inside and need not install water pump outsid...

Page 27: ...please screw down the pressure to adjust the screw B 4 When the system need fill water at first wrest the handle A of filled water Then the handle A can return close when the system is full of water...

Page 28: ...endix 4 The way of assistant heat source connection Unit provides the connection of assistant heat source which can not be only for gas fired boiler but also for electronic boiler or warm net pipe for...

Page 29: ...It is advised to control equipment by mobile terminal after connection to WiFi module B Connect with external water pump Note Connect frequency water pump PWM control to reserved interface as required...

Page 30: ...life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Direc...

Page 31: ...ase line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 1...