EvoHeat Advanced DHP-R Manual 

9. Maintenance 

Do I need to get my unit serviced? 

It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or 

refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary. 

During the service, they will check the operational pressures of the refrigeration system and give the unit and fins a 

good clean to ensure maximum performance. 

Do we have recommended service agents? 

EvoHeat have a large database of recommended service agents. Please contact EvoHeat tech support on 1300 859 

933 for your local service agent details. 

Should I check my unit regularly? 

We recommend you check your unit regularly to avoid potential issues and damage to your heat pump. 

What should I be checking regularly? 

Check the water inlet/outlets often for leaks. You should avoid the condition of no water or air entering into the 

system, as this will influence unit’s performance and reliability. 

You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of clogged filter. 

The area around the unit should be dry, clean and well ventilated. Make sure there is nothing blocking the airflow of 

the heater e.g. Leaf litter. 

Discharge all water in the water pump and water system, so that freezing of the water in the pump or water system 

does not occur. You should discharge the water at the bottom of water pump if the unit will not be used for an 

extended period. You should check the unit thoroughly and fill the system with water fully before using it for the first 

time after a period of time. 

Check the power supply and cable connection often, should the unit begin to operate abnormally, switch it off and 

contact the qualified technician 

 

Refer to our website evoheat.com.au for more maintenance, trouble shooting and energy saving tips. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Advanced DHP-R Series

Page 1: ......

Page 2: ...___________________________________________________________________ 11 6 2 1 Start up Shut Down__________________________________________________________________________ 11 6 2 2 Switching Modes Setti...

Page 3: ...y your pool at any time of the year with the powerful Evo Advanced DHP R Extremely energy efficient C O P up to 5 4 Available in 5 models 9kW to 26 9kW Low ambient air performance Heating and cooling...

Page 4: ...3 EvoHeat Advanced DHP R Manual 2 Unit Dimensions DHP 20R DHP 30R DHP 40R DHP 50R Size mm A B C D E F G DHP 20R DHP 30R 680 645 720 422 663 686 40 DHP 40R DHP 50R 700 700 848 400 720 745 40 DHP 603R...

Page 5: ...rubber pads under the feet of the unit 3 Install the supplied condensation barb to the underside of the unit and direct the condensation to an appropriate drainage point PLUMBING INSTALLATION PLEASE N...

Page 6: ...display on the main screen to enter the parameter menu a Click the sun icon to activate heating mode b Click the temperature display to set the desired pool water temperature c Enter the temperature...

Page 7: ...toppage the unit will not start for at least 3 minutes For unit cleaning or maintenance switch off and disconnect the power of the unit Do not install the unit near flammable gas or spray flammable su...

Page 8: ...Location Recommendations Installation and service must be performed by a qualified installer Evo recommend the heat pump should be installed in an outdoor location with appropriate ventilation Install...

Page 9: ...VOHEAT heat pumps have a factory preset internal water flow switch If there is insufficient water flow the heater will not operate It is CRITICAL that there is sufficient water flow to the unit Incorr...

Page 10: ...ondensate water to an appropriate location NOTE A quick way to verify that the water is condensation is to shut off the unit and keep the pool pump running If the water stops running out of the basepa...

Page 11: ...the installation location 4 The heater must be equipped with a circuit breaker and isolation device 5 Circuit breaker must be installed between the heater and the water circulation pump if the water p...

Page 12: ...perature and power curve 8 Water Inlet Temperature Press to enter mode setting and the target temperature interface 9 LOCK Click to lock the screen To unlock press this button again and enter the code...

Page 13: ...Name Button Colour Function 1 Timing Start Button Start Green End Grey Click this button to start or end the timing start setting function 2 Timing On Setting Click to set the start time of the timer...

Page 14: ...urn off this setting once it reaches the end time 6 2 5 Fault History To view the fault records press 4 If there is no failure the main interface will display a static When a fault occurs the fault ic...

Page 15: ...The ambient temp is low Secondary Anti freezing Prot E29 The ambient temp is low Inlet and oulet temp too big E06 Water flow is not enough and low differential pressure Check the pipe water flow and...

Page 16: ...t voltage measurement Inv Sampling Volt F11 The input voltage sampling fault Check and adjust the current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Check the communication connection...

Page 17: ...et temperature set point 27 C Adjustable Heating the target temperature set point 27 C Adjustable Automatic target temperature set point 27 C Adjustable 7 2 Interface Drawing 7 2 1 Wire Control Interf...

Page 18: ...ater input temperature input 14 AI DI07 Water output temperature input 15 AI DI08 System fan coil temperature input 16 AI DI09 Ambient temperature input 17 AI DI10 Mode switch input 18 AI DI11 Master...

Page 19: ...18 EvoHeat Advanced DHP R Manual 8 2 PCB Description...

Page 20: ...2 70mm2 250A 30mA less than 0 1 sec 186 224A 2 x 95mm2 95mm2 280A 30mA less than 0 1 sec Three Phase Unit Nameplate maximum current Phase line Earth line MCB Creepage Protector Signal Line No more tha...

Page 21: ...nlet outlets often for leaks You should avoid the condition of no water or air entering into the system as this will influence unit s performance and reliability You should clear the pool spa filter r...

Page 22: ...g or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b provide a copy of your r...

Reviews: