25
2551868A
ViewSmart Room controller connections
The Room controller is a white ABS box with a graphic display. It should be installed in the main
living area of the dwelling. It must be connected to the connection board within the ModuSat®
(please refer to the electrical diagram)
. The cable must not be installed adjacent to other 220/240
Volt (AC) lines.
Power Supply for ViewSmart
The ModuSat® room controller’s power is supplied by the ModuSat® board and
does not require batteries or additional power cabling.
External Valve and Pump Requirements
When connecting external valves or pumps to the control board of the ModuSat®
it must be ensured that each connection does not exceed 1amp @ 220/240V (AC).
Cable Requirement
ViewSmart should be connected to ModuSat® connection board with 4 core x 0.33
mm
2
screened cable
Dimensions:
H= 80 mm
L= 130 mm
D= 22 mm
To open the cover to access connections, use a screwdriver in the tab at the bottom as shown
below.
Step 1
To open the cover to access
connections, use a screwdriver
in the tab at the bottom as
shown below.
Step 2
Once the tab has been released the
cover can be hinged up to access
connection
Step 3
Connection terminal with room
controller