background image

Maintenance

Heat pump water heater is a high automatic equipment, please perform regular inspection

termly. If the unit can be long-term and efficiently maintenance, the operating reliability

and service life will have an unexpected increase.

1.The extra water filters should be cleaned regularly to ensure clean water quality of the

   system,  and to avoid damage caused by dirty water filter blocking.

2.Users should pay attention for usage and maintenance to below : all units' protection

   devices are set up before leaving factory, do not make any adjustment by yourself.

3.Frequently check the power supply and electrical wiring system is solid or not, whether

   electrical components are abnormally working, if yes, should timely maintenance and

   change for a new one.

4.Perform regular checks of the water supply system, check whether the tank safety valve,

   liquid level controller and exhaust devices work properly, so as to avoid air into the system,

   and reduce the water cycle volume, thus affect the heating function and operation reliability.

5.Check whether pumps and water valves are normal working or not, whether water tubing

   and water pipes connector are leakage or not.

6.The unit and around should remain clean, well-ventilated. Regularly clean (1-2 month)the

   side air heat exchanger to maintain a good effect of heat exchange.

7.Frequently check whether each part of the unit work  normal or not, check whether there is

   oil on the pipeline joints and  charging valve  to ensure that no refrigerant leakage.

8.Do not piling up debris around the unit, so as not to block from air inlet and outlet, the unit

   around should be kept clean the dry, well-ventilated.

9.If the unit stops for a longer time, should drain all the water in the pipeline, cut off power

   supply, and sets the protective equipment.When re-run the unit, complete inspection is a

   must before reboot.

10.When unit failure, and the user can not resolve the problem, please call our Company in

   local maintenance department, in order to promptly send people for maintenance.

11.Host condenser cleaning.We propose to use 50

-60

, and 15% hot phosphoric acid for

   condenser cleaning, launch the  circulating pump of the host unit for three hours'  cleaning,

   finally rinse with water three times. (Propose to back up a 3-way connector when installing

   the pipeline, block one joint),in order to clear the connection pipe. Do not use corrosive

   cleaning fluid for condenser cleaning.

12.Water tanks need to remove theWater scale after some time (normally two months,

   according to the water quality of local place).

.Maintenance

Water heater

16

Summary of Contents for SWBH-15.0H-B/P-S

Page 1: ...Installation Instruction Manual EVI 80 C HEAT PUMP WATER HEATER MODEL SWBH 15 0H B P S...

Page 2: ...customers Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 6 Wire Circuit Diagram 11 Installation instructions 12 Maintenance 16 1 CONTENTS Water heater C...

Page 3: ...ponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water or...

Page 4: ...Heat pump not only use less electricity to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Ho...

Page 5: ...mpressor compress it the refrigerant gas became high temperature and high pressure Then the gas come into the water condensation into liquid emit a lot of condensation heat condensing heat absorbed by...

Page 6: ...1300 500 1370 160 SWBH 15 0H B P S Model Rated heating capacity w Power supply V Ph Hz Input power kw heat up water heat up water Running current A Thermostat factory setting Thermostat maximum setti...

Page 7: ...The dimension for air source heat pump water heater SWBH 15 0H B P S low ambient Dimension Water heater 5 Measure mm 1300 765 420 1370 460 500...

Page 8: ...k setting press once to return to main interface Start up state Stand by state 1 2 Initialization Operation introductions Water heater 2 2 for Status Inquiry 2 2 1 Press once to check each actual temp...

Page 9: ...ame time for 3 seconds to lock or unlock the keyboard Clock setting 3 3 Clock Setting 3 3 1 On main interface press once to enter clock setting interface 3 3 2 press or to change the clock setting Pre...

Page 10: ...one to confirm setting 3 5 Press both and at the same time for 5 seconds to enter force defrost heating symbol long flashes On enquiry state stop operation within for 10 seconds to return to main inte...

Page 11: ...e protect temperature memory Maximum Water Inlet temp Minimum Water Inlet temp Setting range 20 80 1 12 15 90 MIN 1 20 30 0 1 30 30 90 MIN 1 12 MIN 0 1 10 48 F F 0 1 10 48 F F 100 125 0 1 60 80 20 40...

Page 12: ...When 5 C ambient temp 15 C Set point temp Data of Parameter 16 Data of parameter 16 data of parameter of 17 15 5 Ambient temp 5 For example when ambient temp is 18 deg c Parameter 16 data is 60 deg c...

Page 13: ...OUT2 OUT3 OUT4 OUT7 OUT5 OUT8 OUT6 OUT9 5 5 Electronic Expansion Valve 1 Electronic Expansion Valve 2 CONTACTOR 1 CONTACTOR 2 CONTACTOR 3 6 5 4 3 2 1 FM1 PM FM2 Fan Motor T1 P1 T2 P2 T3 P3 T4 P4 T5 P5...

Page 14: ...to the distance between the barriers shown in below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or...

Page 15: ...llation 1All the pipeline tubing should be matched as shown on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat...

Page 16: ...eters valves water flow switch are safe and correct 1Check if having opened all the valves that should be opened and having closed all valves that should be closed 1Check if all necessary attemperator...

Page 17: ...least 2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degree...

Page 18: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Page 19: ...EVI 80 C Heat Pump Water Heater...

Reviews: