FITTINGS

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected 
from the supply source.

HOSES

Air hoses should have a minimum of 10.6 bar (150 PSI ) working pressure rating or 150 percent of the maximum pressure 

that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” 
from the male plug on the tool.

SUPPLY SOURCE

Use only clean, regulated compressed air as a power source for this tool. Never use oxygen, combustible gases, or bottled 
gases as a power source for this tool as the tool may explode.

REGULATOR

A pressure regulator with an operating pressure of 0 ~ 8.79 bar (0 ~ 125 PSI) is required to control the operating pressure 
for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 14 bar (200 PSI) as tool 

may fracture or burst, causing injury.

OPERATING PRESSURE

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air supply must be 
capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving 
power. Refer to “Tool Specifications” for setting the correct operating pressure for the tool.

FILTER

Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance 
and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to 
be kept clean to be effective in providing clean compressed air to the tool.
Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and/or clogged filter will cause a 
pressure drop which will reduce the tool’s performance.

DO NOT USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES AS A POWER SOURCE FOR 
THIS TOOL AS TOOL MAY EXPLODE, POSSIBLY CAUSING INJURY.

OPERATION : 

AIR SUPPLY AND CONNECTIONS

C

2

H

2

O

2

12

Summary of Contents for FCN90B

Page 1: ...B SCN90L PN90 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE...

Page 2: ...application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp No 7 Wugong 7th Road Wufeng District Taichung City...

Page 3: ...coverage is limited to 90 days due to high volume usage warranty on production tools cannot be guaranteed due to unpredictable circumstances Tools are subjected to abuse such as hammering or usage of...

Page 4: ...rma armonizzata EN ISO 11148 13 2018 CE Declaracion de conformidad EVERWIN PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta enconformidad con las Directivas Europeas...

Page 5: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Page 6: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Page 7: ...and appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surface...

Page 8: ...pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disco...

Page 9: ...3 1 2 50 90mm 2 3 1 2 Wire 2 5 3 8mm 0 099 0 148 Plastic 2 5 2 9mm 0 099 0 113 2 5 3 8mm 0 099 0 148 6 5 7 7mm 0 256 0 303 6 5 7 7mm 0 256 0 303 Smooth Ring Screw Smooth Ring Screw 15 Wire Plastic 15...

Page 10: ...L 105 2 SCN90L 105 2 PN90 109 5 dBA These values are determined and documented in accordance to EN12549 VIBRATION Vibration characteristic value FCN90B 4 57m s2 FCN90LB 3 68m s2 SCN90L 3 68m s2 PN90 4...

Page 11: ...tial Trip available system on FCN90B ST FCN90LB ST SCN90L ST PN90 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes accurate fastener...

Page 12: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Page 13: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Page 14: ...particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply loading operating or servicing this tool Eye protection is requir...

Page 15: ...rface Pull the trigger and then tap the contact trip against the work surface using a bouncing motion Each depression of the contact trip will cause a fastener to be driven 2 Sequential Trip Operation...

Page 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Page 17: ...rection to turn the Adjustment dial 4 Reconnect air supply The tool is equipped with a Trigger Lock mechanism Push and rotate the Trigger Lock Dial to the trigger free position before driving nails LO...

Page 18: ...rom the effects of dirt and water in the system Restricted air flow will prevent the tool from receiving an adequate volume of air even though the pressure reading is high The results will be slow ope...

Page 19: ...19...

Page 20: ...20...

Reviews: