background image

NOTE: DIAGRAMS & ILLuSTRATION ARE NOT TO SCALE.

15

FIREboX FINIshEs

There are a wide variety of “finished looks” for your built-in Vent-Free 

firebox from formal wall decor with elaborate mantels to rustic wood 

paneling or warm brick facings.

Only noncombustible materials like marble, stone, tile, brick, etc. may 

overlap the black front facing.  Seal all joints between the black facing 

Raised hearth Extension

(combustibles allowed. 

No carpet or vinyl)

combustible Platform

sIDE VIEW

Firebox Floor

combustible Wall

Figure 23 - Raised Hearth Extension

Non-combustible Wall 

(see

 Figure 4)

Fireplace opening

* From base to bottom of 

Firebox  opening (floor) 

5-3/4" max.*

base

and wall surrounds to prevent air intrusion. Use noncombustible caulking 

material only to seal the black metal facing to the surround material on 

the finished wall.  See 

Figures 3 and 23

.

Raised hearth Extension

A hearth extension may be used but is not required for these appliances.  

A raised hearth extension may be used as shown in 

Figure 23

.

Summary of Contents for EWVF36

Page 1: ...AND OPERATION INSTRUCTIONS EWVF36 WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life For use only wit...

Page 2: ...to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More freq...

Page 3: ...Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions Warranty Certificate General Information TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDe...

Page 4: ...maximumBTU Hrthespacecan support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the space ca...

Page 5: ...ined In no case shall the clearances be such as to interfere with combustion air and accessibility d Installations shall be of a permanent type with a permanently piped fuel supply in accordance with...

Page 6: ...Do not install in the vicinity where gasolineorotherflammableliquids may be stored The Vent Free fire boxmustbekeptclearandfreefrom these combustible materials WARNING Do not use a blower insert heat...

Page 7: ...such as carpeting vinyl tile etc a metal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance Model EWVF36 WITH Hood Installed Hood is required on all...

Page 8: ...nt sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed at the time of installation or...

Page 9: ...d surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the f...

Page 10: ...Weight lbs Shipping Volume EWVF36 150 lbs 20 Cu Ft A hood comes standard and is required for model EWVF36 The factory supplied hood must be installed on the firebox for safe operation in all installa...

Page 11: ...shown in Figure 10 Step 2 Align the hood with the holes in the side frames as shown in Figure 11 Install three screws as shown in Figure 11 Make sure hood is level and secure Step 3 Reinstall screen...

Page 12: ...on Box Factory Wired Blower Tab Intact Plug blower into this receptacle Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE A ON OFF Wall Swit...

Page 13: ...9 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the b...

Page 14: ...box wires The strain relief bushing should be pressed into the knock out on J box cover around the Romex this will provide protection to the wires and prevents strain against connections from J box Se...

Page 15: ...xtension combustibles allowed No carpet or vinyl Combustible Platform SIDE VIEW Firebox Floor Combustible Wall Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening Fro...

Page 16: ...ed with the touch up paint kit Touch Up Paint Kits ModelNo Description FTPK B Touch Up Paint Black ref Form 750050M PA I N T The variable speed control rheostat is included with EWFBK200 models only A...

Page 17: ...number of the firebox 2 The serial number of the firebox 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the firebox REPLACEMENT PARTS 3 4 5 2 1 6 3...

Page 18: ...1026 Old Stage Rd Simpsonville SC 29681 CUI reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Reviews: