HD9690 Series HDTV Graticule Generator Manual
Page 2-2
Revision 1.5
INSTALLATION
When the 3D option is fitted and operating the Graticule generator in the 4:2:2 mode, the
stereoscopic 4:2:2 output video with graticules will be available on the
A/4:2:2
and
B
outputs. The Left Eye signal will be available on the
A/4:2:2
output and the Right Eye signal
will be available on the
B
output.
HD OUTPUT 4:2:2 MON
When operating the Graticule generator in the 4:4:4 mode, this BNC
contains a down samples 4:2:2 copy of the output video with graticules. When operating the
Graticule generator in the 4:2:2 mode this BNC contains a second copy of the input video
with graticules. When the 3D option is fitted and operating the Graticule generator in the
4:2:2 mode this BNC contains a second copy of the Left Eye signal.
2.1.3. DVI Video Connections
DVI OUTPUT
This VESA DVI-I connector provides progressive RGBHV and DVI-D outputs suitable for
driving a computer video monitor. The monitor must be capable of scanning at the line and
pixel rate of the video input standard you are using.
Recommended maximum cable lengths:
•
DVI digital max length = 3 meters, or 10 feet
•
VGA analog max length = 5 meters, or 15 feet
2.1.4. Serial I/O and GPI/O Connections
UPGRADE/COM1
This 9 pin female D connector provides an RS-232 serial interface used for updating
the firmware. This port is wired at the factory as an RS232 DCE port as shown in Table 2-1.
Pin #
Name
Description
1
GND
Chassis ground
2
TxD
RS-232 Transmit Output
3
RxD
RS-232 Receive Input
4
5
Sig Gnd
RS-232 Signal Ground
6
7
RTS
RS-232 RTS Input
8
CTS
RS-232 CTS Output
9
Table 2-1: Remote CTL Port Pin Definitions
REMOTE PANEL
This female 9 pin D connector is for the RS-422 serial interface to the optional
remote control panel. This connector is not installed on units with integrated control panels.
See 2.7 for information about connecting the remote panel to the main unit.