![evertz EQT-1616-3G-F User Manual Download Page 26](http://html.mh-extra.com/html/evertz/eqt-1616-3g-f/eqt-1616-3g-f_user-manual_2445234026.webp)
EQT-1616-3G-F
EQT 12G/3G/HD Router
Page 14
4.1.2. Rear View
There are a number of communication connections on the rear of the EQT frame. Figure 4-3 identifies all
the connectors on the rear panel. These connectors provide access to the various communications
facilities of the EQT router, such as control and video status monitoring.
Figure 4-3 : Rear Communication Connections on EQT-1616-3G-F Rear Plates
4.2. SYSTEM CONFIGURATION
4.2.1. Setting the IP Address
The EQT-1616-3G-F consists of two individual components, Router and Control Panel, that each have
their own IP address. These components can be accessed through either Ethernet or Serial ports, both
on the rear panel of the device.
When shipped from factory, the default IP addresses of the devices are as follows:
Router Component (EQT):
192.168.245.17
Control Panel Component:
192.168.245.18
To change the IP address of the components via Ethernet, follow the instructions below:
For the EQT:
1. Telnet to port 23 of the EQT IP address
2. Log in using login/password combination
customer/customer
3. Once the configuration menu is displayed, select the Network Setup menu
4. Follow the on-screen instructions to set the IP address, subnet mask, gateway, and broadcast
address
5. Make sure to select the option to Save and Exit when changes are complete
6. Wait 30 seconds for changes to be applied
7. Reboot the EQT for changes to take effect
For the Control Panel:
1. Telnet to port 23 of the Front Panel IP address
2. Once the configuration menu is displayed, select the Network Setup menu
3. Follow the on-screen instructions to set the IP address, subnet mask, gateway, and broadcast
address
4. Make sure to select the option to Save and Exit when changes are complete
5. Wait 30 seconds for changes to be applied
6. Reboot the EQT for changes to take effect
Summary of Contents for EQT-1616-3G-F
Page 2: ...This page left intentionally blank ...
Page 6: ...EQT 1616 3G F EQT 12G 3G HD Router Page ii This page left intentionally blank ...
Page 12: ...EQT 1616 3G F EQT 12G 3G HD Router Page viii Page left intentionally blank ...
Page 22: ...EQT 1616 3G F EQT 12G 3G HD Router Page 10 Page left intentionally blank ...
Page 36: ...EQT 1616 3G F EQT 12G 3G HD Router Page 24 This page left intentionally blank ...
Page 40: ...EQT 1616 3G F EQT 12G 3G HD Router Page 28 Page left intentionally blank ...
Page 43: ...EQT 1616 3G F EQT 12G 3G HD Router Page 31 6 3 SYSTEM Figure 6 3 WebEASY System ...
Page 48: ...EQT 1616 3G F EQT 12G 3G HD Router Page 36 6 6 SIGNAL STATUS Figure 6 6 WebEASY Signal Status ...
Page 53: ...EQT 1616 3G F EQT 12G 3G HD Router Page 41 6 8 GPIO Figure 6 10 WebEASY GPIO ...
Page 58: ...EQT 1616 3G F EQT 12G 3G HD Router Page 46 7 2 SYSTEM Figure 7 1 VistaLINK System ...
Page 74: ...EQT 1616 3G F EQT 12G 3G HD Router Page 62 This page left intentionally blank ...
Page 85: ...EQT 1616 3G F EQT 12G 3G HD Router Page 73 Figure 8 10 WinSeup Ethernet Port Settings Serial ...
Page 88: ...EQT 1616 3G F EQT 12G 3G HD Router Page 76 Page left intentionally blank ...
Page 102: ...EQT 1616 3G F EQT 12G 3G HD Router Page 90 End of Document ...