7780M4-ASI / 7780D4-ASI
Quad ASI TDM-Mux/Demux
Revision 1.0
Page 15
7.
CARD CONFIGURATION – 7780D4-ASI
7.1.
CONFIGURING THE 7780D4-ASI USING VISTALINK
®
Expand the Hardware tree from the VLPro window. Locate the IP address of the frame controller in
which the card(s) have been installed. Click the “+” button to expand the frame. The card you have
installed should be displayed as a sub component of this frame, and should be named appropriately,
7780D4-ASI, followed by square brackets to indicate the slot number used.
7.2.
ASI OUT 1/2/3/4
Right-click the card and select
View Configuration
from the context sensitive menu. You will be
presented at first with the “ASI OUT 1” tab. The following three tabs labeled ASI OUT 2 / ASI OUT 3 /
ASI OUT 4 have identical controls and layout but refer to each of the separate outputs. For the sake of
brevity, only ASI OUT 1 will be described in detail.
The configuration window in Figure 7-1 will appear in the right-hand side of the screen:
Figure 7-1: ASI OUT 1 – 7780D4-ASI
7.2.1. Control
•
Reset Measurements:
The
Reset Measurements
button allows the user to reset the Monitor
window.
•
ASI Output Mode:
The
ASI
Output Mode
control enables the user to set the output mode to
Discontinuous
or
Continuous
mode.