7700
MultiFrame
Manual
7707MTA-HD Multi-Signal HD/SD, AES, and Control Fiber Transmitter
Page-20
Revision 1.3
4.2.14. Selecting the Serial Data Rate
A serial data rate selection is only required for RS-485 data. To select the serial data rate, select the
CTRL
(Control) menu item in menu level 1, followed by the
SER
(Serial Data), followed by the
RATE
(Baud Rate).
CTRL
SER
RATE
SELECTIONS
PER TABLE
300
Configures card to transmit
at 300Kb/s
600
Configures card to transmit
at 600 Kb/s
1K2
Configures card to transmit
at 1.2 Kb/s
2K4
Configures card to transmit
at 2.4 Kb/s
4K8
Configures card to transmit
at 4.8 Kb/s
9K6
Configures card to transmit
at 9.6 Kb/s
14K4
Configures card to transmit
at 14.4 Kb/s
19K2
Configures card to transmit
at 19.2 Kb/s
38K4
Configures card to transmit
at 38.4 Kb/s
57K6
Configures card to transmit
at 57.6 Kb/s
76K8
Configures card to transmit
at 76.8 Kb/s
115K
Configures card to transmit
at 115 Kb/s
153K
Configures card to transmit
at 153 Kb/s
4.2.15. Selecting the Serial Data Fail Safe Bias
RS-485 applications sometimes require a failsafe bias at the serial data interface, to ensure a known
signal state while communications are in an idle state. The 7707MTA-HD provides a configurable failsafe
bias to accommodate such requirements. To configure the failsafe bias, select the
CTRL
(Control) menu
item in menu level 1, followed by the
SER
(Serial Data), followed by the
BIAS
(Failsafe Bias).
CTRL
SER
BIAS
ON
OFF
ON
Enables fail safe bias
OFF
Disables fail safe bias
4.2.16. Selecting the Audio Embedding Groups
This user menu item provides configuration of the embedded audio groups. Incoming embedded audio
groups are cleaned from the video, and should be re-assigned as desired using this menu option. To
select the audio embedding groups select the
CTRL
(Control) menu item in menu level 1, followed by the
EMBD
(Audio Embedding),
AUD
(Audio), and
GRP1, GRP2, GRP3
or
GRP4
menu items. Then, select
from
CH1
or
CH2
(channel 1 or 2) for that audio group.