7.5.3.2. Optical Monitor
Optical Power:
Displays the “Optical Power” level.
7.5.3.3. Data Input & Output Status
These fields indicate the presence of “Data Input” and “Data Output” signals.
7.5.3.4. Audio Input & Audio Output Status
These fields indicate the presence of “Audio Input” and “Audio Output” signals as per configured detection
threshold.
7.5.3.5. Faults
The
Faults
control, as illustrated in Figure 7-4, allows the user to enable or disable traps and view trap
status. To enable a particular trap, simply click the box located beside each trap so that a check-mark
appears. When a check-mark is present, the trap is enabled. When a check-mark is not present, the trap
is disabled.
The
Trap Status
section defines whether a trap is present or missing. If the box is green, then the
corresponding trap is present. If the box is red, then the corresponding trap is missing.