The 7700ACO-HD has 8 LED Status indicators on the front card edge to show operational status of the 

card at a glance. Figure 4-1 shows the location of the LEDs and card edge controls. 

 

7700ACO-HD

toggle

switch

BANK

SELECTION

A

LOCAL

FAULT

MODULE

OK

push

button

LOCAL /

REMOTE

B

1  2  3  4

A

B

BANK

PRESENCE

 

Figure 4-1: Status LED Locations 

 

Two large LEDs on the front of the main board indicate the general health of the module. 

 

LOCAL FAULT: 

This Red LED indicates poor module health and will be ON during the absence of a 

valid input signal or if a local input power fault exists (i.e.: a blown fuse). The 

LOCAL FAULT indication can also be reported to the frame through the FRAME 

STATUS jumper.  

 

 

The Red LED will also indicate any differences in signals on Bank A and B (based 

on POOL settings).  The 7700ACO-HD expects to have an equal number of inputs 

on Banks A and B.  If there is a discrepancy, this is considered a fault condition 

since a switch from the primary (or active) bank to the secondary bank will result 

in a loss of video or audio (depending on the missing input signal). 

 

MODULE OK: 

This Green LED indicates good module health. It will be ON when a valid input 

signal is present, and the board power is good. 

 

4.1.  BANK SELECTION LEDS 

These two LEDs indicate which input is providing the source for the output.  Input A is located at the top 

leftmost LED. 

 

LED 

Colour 

Description 

Off 

Bank A is not selected as a source for output. 

Green 

Bank A is selected as source for output. 

Off 

Bank B is not selected as source for output. 

Yellow 

Bank B is selected as source for output. 

Table 4-1: Bank Selection LEDs 

Summary of Contents for 7700ACO-HD

Page 1: ...vertzTV Version 1 3 July 2020 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 7700Multiframe Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 7700AC0 HD All rights reserved No part of this publication may be reproduced witho...

Page 2: ...This page left intentionally blank ...

Page 3: ...rd grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufa...

Page 4: ...ber Non reversible damage to the eye can occur in a matter of milliseconds Do not hook up the 7707MB DWDM cards directly with a short fiber optic cable The 7707MB DWDM cards produce 7dBm of power which will damage the receiver if connected directly ...

Page 5: ...ly to cause harmful interference in which case the user will be required to correct the interference at his own expense INFORMATION TO USERS IN THE U S A NOTE FCC CLASS A DIGITAL DEVICE OR PERIPHERAL This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against ...

Page 6: ...This page left intentionally blank ...

Page 7: ...irmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken in the Evertz sales contract or order confirmation Information contained in this manual is periodically updated and changes will be incorpor...

Page 8: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page ii Revision 1 3 This page left intentionally blank ...

Page 9: ...RICAL 8 3 8 PHYSICAL 8 4 STATUS INDICATORS 9 4 1 BANK SELECTION LEDS 9 4 2 BANK PRESENCE LEDS 10 4 3 LOCAL REMOTE STATUS 10 5 CARD EDGE CONTROLS 11 5 1 1 Setting Local or Remote Module Control 11 5 1 2 Setting Control or Monitor Mode 12 6 CARD EDGE MENU SYSTEM 13 6 1 NAVIGATING THE MENU SYSTEM 13 6 2 CARD EDGE STATUS MESSAGES 13 6 2 1 Display Type of Signal present on HD SD Input A 14 6 2 2 Displa...

Page 10: ...Pool 19 6 10 SETTING THE TYPE OF AUTO CHANGEOVER MODE 19 7 JUMPERS 20 7 1 SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS 21 7 2 CONFIGURING THE MODULE FOR FIRMWARE UPGRADES 21 8 VISTALINK REMOTE MONITORING CONTROL 22 8 1 WHAT IS VISTALINK 23 8 2 VISTALINK MONITORED PARAMETERS 24 8 3 VISTALINK CONTROLLED PARAMETERS 24 8 4 VISTALINK TRAPS 26 9 MENU QUICK REFERENCE 27 ...

Page 11: ...raps 25 Figure 8 5 VistaLINK Control 26 Figure 8 6 VistaLINK Traps 26 Tables Table 2 1 AES IN A and AES IN B Audio Connector Pin Out 4 Table 2 2 AES OUT Audio Connector Pin Out 4 Table 2 3 AES Audio Breakout Cable Evertz Part WPAES8 BNCM 6F 5 Table 2 4 GPI Operations 6 Table 2 5 GPO Status 6 Table 4 1 Bank Selection LEDs 9 Table 4 2 Bank Presence LEDs 10 Table 4 3 Local Remote LED 10 Table 5 1 DIP...

Page 12: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page vi Revision 1 3 This page left intentionally blank ...

Page 13: ...o manage the module status monitoring and configuration from SNMP enabled control systems such as Evertz VistaLINK Features Auto detection of signal standard Four modes of operation Auto changeover two standalone auto changeovers Manual DIP switch control two independently controlled 2x1 switchers GPI Control two independently GPI controlled 2x1 switchers Tally output provided Protection for 8 cha...

Page 14: ... HD SD EQ Latching Relay AES Rx AES Rx HD SD SDI Inputs AES Inputs 1 8 A B HD SD SDI Out AES 1 8 Out Latching Relay VistaLINK Interface A B GPI Interface Format Validation GPIO Processor Selector Guide 8 8 8 8 8 8 8 COM Out Latching Relay A B 4 4 4 DB15 to 8 channel unbalanced AES adapter provided Figure 1 1 7700ACO HD Block Diagram ...

Page 15: ...0FR chapter Figure 2 1 Rear Panel 2 1 VIDEO CONNECTIONS HD SDI INPUT A and B The input BNC connector for 10 bit serial digital video signals compatible with the SMPTE 292M SMPTE 259M or SMTPE 310M standard HD SDI OUT This BNC connector is used to output the video as serial component video compatible with the SMPTE 292M or SMPTE 259M standard same as input with embedded audio Unused HD SDI OUT conn...

Page 16: ...6 AES In 2 AES Input 2 Unbalanced 7 Reserved for Future Use 8 AES In 6 AES Input 6 Unbalanced 9 AES In 5 AES Input 5 Unbalanced 10 AES In 1 AES Input 1 Unbalanced 11 AES In 8 AES Input 8 Unbalanced 12 AES In 7 AES Input 7 Unbalanced 13 AES In 4 AES Input 4 Unbalanced 14 AES In 3 AES Input 3 Unbalanced 15 GND Ground Shell Table 2 1 AES IN A and AES IN B Audio Connector Pin Out Name Description DB 1...

Page 17: ...ldered to DB15 Shell AES A1 BNC MALE AES In 1 AES Out 1 12 Coax Soldered to DB15 Shell AES B4 BNC MALE AES In 8 AES Out 8 13 Coax Soldered to DB15 Shell AES B3 BNC MALE AES In 7 AES Out 7 14 Coax Soldered to DB15 Shell AES A4 BNC MALE AES In 4 AES Out 4 15 Coax Soldered to DB15 Shell AES A3 BNC MALE AES In 3 AES Out 3 Shell Black GND WIRE GND GND Table 2 3 AES Audio Breakout Cable Evertz Part WPAE...

Page 18: ...GND GND Figure 2 3 GPIO Pin Out The two GPI s are active if the MODE is set to either GPI or MAN see section 6 4 Table 2 4 shows the operations that the two GPI s control GPI 1 GPI 2 Operation Low Low Current bank selected no change Low High Master A inputs selected High Low Master B inputs selected High High Current bank selected no change Table 2 4 GPI Operations The two GPO s are active in all ...

Page 19: ...PTE 310M same as input Number of Outputs 1 Passive Relay Output Connector BNC per IEC 61169 8 Annex A Maximum Cable Length 60m of Belden 1694 or equivalent cable combined input and output Signal Level 800mV nominal DC Offset 0V 0 5V Return Loss 12 dB up to 1 5GHz 3 3 AES INPUTS Number of Outputs 8 Unbalanced AES per connector Connectors 2 Female High Density DB 15 Input Level 1V p p Input Impedanc...

Page 20: ...k internal pull up to 5V Ground to rear panel when relay is in active position Connectors Screw down terminal block Signal Level 5 V nominal 3 6 COMMUNICATIONS AND CONTROL Serial Port RS232 RS422 4 wire terminal block Connectors Terminal block 3 7 ELECTRICAL Voltage 12VDC Power 6 Watts EMI RFI Complies with FCC regulations for class A devices Complies with EU EMC directive 3 8 PHYSICAL Number of s...

Page 21: ...eported to the frame through the FRAME STATUS jumper The Red LED will also indicate any differences in signals on Bank A and B based on POOL settings The 7700ACO HD expects to have an equal number of inputs on Banks A and B If there is a discrepancy this is considered a fault condition since a switch from the primary or active bank to the secondary bank will result in a loss of video or audio depe...

Page 22: ... where any signal in the pool is present LED Colour Description A Off Bank A is not present Green Bank A is present B Off Bank B is not present Green Bank B is present Table 4 2 Bank Presence LEDs 4 3 LOCAL REMOTE STATUS This LED indicates whether the 7700ACO HD is controlled locally via card edge or remotely via VistaLINK LED Colour Description Local Remote Off Remotely controlled via VistaLINK o...

Page 23: ...e used to scroll build and card information or display the menu options to the user Push Button This component will become active once the card has completed booting It is primarily used for navigating through the menu system DIP Switch The 7700ACO HD is equipped with a 4 position DIP switch to allow the user to set how the module will be controlled and monitored Table 5 1 gives an overview of the...

Page 24: ...Description Value Description 1 2 3 4 Off Control or Monitor Mode The module is in control mode The module can be configured by either card edge or VistaLINK depending on the setting of DIP switch 1 On The module is in monitor mode The card edge display will report status based on the setting of the MONI parameter see section 6 8 Table 5 3 Control or Monitor Switch ...

Page 25: ...d at the desired value depress the pushbutton This will return you to the parameter select menu item you are setting the display shows the parameter name you were setting To change another parameter use the toggle switch to select other parameters If neither the toggle switch nor pushbutton is operated for approximately 30 seconds the card edge control will exit the menu system and return to an id...

Page 26: ...S Input A Both AESA and AESB display the same type of information The card edge 4 character matrix display will show the presence of an AES input The display is read left to right when DISP is set to HORZ see section 6 7 If DISP is set to VERT then the display is read from top to bottom Assuming the DISP is set to HORZ the first character represents the presence of AES inputs 1 and 2 The next char...

Page 27: ...OL Signals to Monitor Selects which signals to monitor ACOM Auto Changeover Mode Sets the type of auto changeover mode Table 6 3 Top Level Menu Structure The menus will timeout approximately 30 seconds after a period of inaction After the timeout period expires the menu will return to MODE menu 6 4 SETTING THE CHANGEOVER MODE MODE This parameter is used to set the switch mode of the 7700ACO HD AUT...

Page 28: ... card edge display when in monitoring mode FULL This displays information related to the bank selected The information that is displayed is the type of video input and which AES channels are present BANK This displays which bank is currently active FULL BANK 6 9 SELECTING WHICH INPUT SIGNALS TO SWITCH ON The 7700ACO HD uses a pool of input signals to determine when to activate a switch between the...

Page 29: ... of the signals in the primary bank disappears a switch to the secondary bank will occur Secondary Bank X X X X X Primary Bank X X X X X The secondary bank is missing AES 1 If AES 3 5 or 8 disappear in the primary bank a switch will NOT occur because the secondary bank does not have AES 1 present If AES 1 also disappears then a switch will occur A switch will occur if the input video signal is los...

Page 30: ... occur VIDE Allows the user to include the input video signal to the pool of monitored signals AES1 Allows the user to include the AES 1 input to the pool of monitored signals AES2 Allows the user to include the AES 2 input to the pool of monitored signals AES3 Allows the user to include the AES 3 input to the pool of monitored signals AES4 Allows the user to include the AES 4 input to the pool of...

Page 31: ... included in the pool of monitored signals VIDE NO YES 6 10 SETTING THE TYPE OF AUTO CHANGEOVER MODE ACOM This parameter allows the user to set the type of changeover that will occur if the MODE parameter is set to AUTO see section 6 4 ACO The module will be in auto changeover mode where input Bank A and B are treated equally ACOA The module will be in auto changeover mode where input Bank A has p...

Page 32: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page 20 Revision 1 3 This page left intentionally blank ...

Page 33: ... this module will not be monitored 7 2 CONFIGURING THE MODULE FOR FIRMWARE UPGRADES Firmware updates can be performed using the UPGRADE jumper UPGRADE The UPGRADE switch is located at J3 jumper on the front side of the main module and is used when firmware upgrades are being done to the module For normal operation it should be switched to the RUN position as shown in the diagrams above See the Upg...

Page 34: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page 22 Revision 1 3 This page left intentionally blank ...

Page 35: ...nd receive feedback that the configuration has been carried out There are 3 components of SNMP 1 An SNMP manager also known as a Network Management System NMS is a computer running special software that communicates with the devices in the network Evertz VistaLINK Pro Manager graphical user interface GUI third party or custom manager software may be used to monitor and control Evertz VistaLINK ena...

Page 36: ... HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page 24 Revision 1 3 8 2 VISTALINK MONITORED PARAMETERS Figure 8 1 VistaLINK Monitored Parameters 8 3 VISTALINK CONTROLLED PARAMETERS Figure 8 2 VistaLINK Module Fault Traps ...

Page 37: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Revision 1 3 Page 25 Figure 8 3 VistaLINK Bank A Fault Traps Figure 8 4 VistaLINK Bank B Fault Traps ...

Page 38: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page 26 Revision 1 3 Figure 8 5 VistaLINK Control 8 4 VISTALINK TRAPS Figure 8 6 VistaLINK Traps ...

Page 39: ...Page 27 9 MENU QUICK REFERENCE Changeover Mode MODE AUTO GPI MAN Factory Reset FRST YES NO Firmware Version VER Display Orientation DISP HORZ VERT Monitor Mode MONI FULL BANK Auto Changeover Mode ACOM ACO ACOA ACD ACDA Input Signals to Monitor POOL VIDE AES1 AES2 AES3 AES4 AES5 AES6 AES6 AES7 AES8 BACK ...

Page 40: ...7700 MultiFrame Manual 7700ACO HD HD SD SDI 8 Channel AES RS 232 RS 422 Auto Changeover Page 28 Revision 1 3 End of Document ...

Reviews: