Frame Manual
500DA2Q-3G 3G/HD/SD-SDI Dual Reclocking Distribution Amplifier
5.
LOCATION OF LEDs AND JUMPERS
FRAME
STATUS
INPUT 1 LOCKED
MODULE STATUS
J1
ON
OF F
INPUT 1
270Mb/s
1.5 Gb/s
RECLOCKER
BYPASS
(2)500DA2Q-3G
3.0 Gb/s
INPUT 1
RECLOCKER CONFIG
J2
BYPASS
RECLOCK
+12V
INPUT 2
270Mb/s
1.5 Gb/s
RECLOCKER
BYPASS
3.0 Gb/s
INPUT 2
RECLOCKER CONFIG
J5
BYPASS
RECLOCK
INPUT 2 LOCKED
Figure 5-1: LED and Jumper Locations
5.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
The FRAME STATUS jumper J1, located at the front of the module, determines whether local faults (as
shown by the Local Fault indicator) will be connected to the 500FR frame's global status bus.
FRAME STATUS:
To monitor faults on this module with the frame status indicators (on the power
supply’s FRAME STATUS LED's and on the Frame's Fault Tally output) install this
jumper in the On position.
When this jumper is installed in the Off position local faults on this module will not
be monitored.
Revision
2.0
Page - 7