background image

Frame Manual 

500DA2Q-3G 3G/HD/SD-SDI Dual Reclocking Distribution Amplifier 

 

TABLE OF CONTENTS 

 

1. OVERVIEW.......................................................................................................................................... 1

 

2. INSTALLATION................................................................................................................................... 3

 

3. SPECIFICATIONS............................................................................................................................... 4

 

3.1. SERIAL 

VIDEO INPUT ............................................................................................................... 4

 

3.2. SERIAL 

VIDEO OUTPUTS......................................................................................................... 4

 

3.3. ELECTRICAL ............................................................................................................................. 4

 

3.4. PHYSICAL .................................................................................................................................. 4

 

4. STATUS 

LEDS .................................................................................................................................... 5

 

4.1.  INPUT 1 INDICATORS ............................................................................................................... 5

 

4.2.  INPUT 2 INDICATORS ............................................................................................................... 6

 

5. 

LOCATION OF LEDS AND JUMPERS .............................................................................................. 7

 

5.1.  SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED 

BY THE GLOBAL FRAME STATUS.......................................................................................... 7

 

5.2. SELECTING 

NON-RECLOCK MODE ........................................................................................ 8

 

6. VISTALINK

®

 REMOTE MONITORING/CONTROL ............................................................................. 9

 

6.1.  WHAT IS VISTALINK

®

? ............................................................................................................. 9

 

6.2. MONITOR 

SETTINGS TAB...................................................................................................... 10

 

6.2.1. Lock 

Status ......................................................................................................................... 10

 

6.2.2. Bypass 

Select ..................................................................................................................... 10

 

6.2.3.  Input Video Rate ................................................................................................................. 11

 

6.3.  FAULT TRAPS TAB................................................................................................................. 11

 

6.3.1.  Module OK Trap Status....................................................................................................... 11

 

Figures 

Figure 1-1: 500DA2Q-3G Block Diagram.............................................................................................................. 2

 

Figure 2-1: 500DA2Q-3G Rear Panel Overlay...................................................................................................... 3

 

Figure 5-1: LED and Jumper Locations ................................................................................................................ 7

 

Figure 5-1: VistaLINK

®

 500DA-3G Monitor Status Tab.......................................................................................10

 

Figure 5-1: VistaLINK

®

 500DA-3G Fault Traps Tab............................................................................................11

 

 

Revision 2.0

 

Summary of Contents for 500DA2Q-3G

Page 1: ...LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS 7 5 2 SELECTING NON RECLOCK MODE 8 6 VISTALINK REMOTE MONITORING CONTROL 9 6 1 WHAT IS VISTALINK 9 6 2 MONITOR SETTINGS TAB 10 6 2 1 Lock Status 10 6 2 2 Bypass Select 10 6 2 3 Input Video Rate 11 6 3 FAULT TRAPS TAB 11 6 3 1 Module OK Trap Status 11 Figures Figure 1 1 500DA2Q 3G Block Diagram 2 Figure 2 1 500DA2Q 3G Rear Panel Overlay 3 Fi...

Page 2: ... performance either expressed or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any erro...

Page 3: ...her SMPTE 344M SMPTE 259M SMPTE 310M and DVB ASI data rates Fully hot swappable from front of frame with no BNC disconnect required Independent isolated output drivers to ensure no cross channel loading effects i e no need to terminate unused outputs Outputs maintain polarity from input to output for DVB ASI applications Tally output on Frame Status bus upon loss of input signal for quality monito...

Page 4: ...Frame Manual 500DA2Q 3G 3G HD SD SDI Dual Reclocking Distribution Amplifier Figure 1 1 500DA2Q 3G Block Diagram Page 2 Revision 2 0 ...

Page 5: ...f the 500FR chapter Figure 2 1 500DA2Q 3G Rear Panel Overlay IN A IN B Input BNC connectors for 10 bit serial digital video signals compatible with the SMPTE 292M SMPTE 259M SMPTE 344M and SMPTE 310M 19 4 Mb s standards or any SDI signal between the range of 143Mb s to 1 5 Gb s OUT 1A to 4A These four BNC connectors are used to output reclocked serial component video from IN A OUT 1B to 4B These f...

Page 6: ...Input B Automatic to 80m 3Gb s 150m 1 5Gb s and 350m 270Mb s with Belden 1694A or equivalent cable Return Loss 15dB up to 1 5GHz 10dB up to 3GHz 3 2 SERIAL VIDEO OUTPUTS Number of Outputs 2 x 4 Mode 4 reclocked from each input Reclockers can by bypassed separately for each input Connector BNC per IEC 61169 8 Annex A Signal Level 800mV nominal DC Offset 0V 0 5V Rise and Fall Time 200ps nominal Over...

Page 7: ...put 1 or input 2 in dual 1x4 mode and board power is good There are two small LEDs at the top of the module that indicate the status of the reclockers INPUT 1 RECLOCKER LOCKED This Green LED will be On when reclocker 1 is locked to a valid signal present at the module input 1 INPUT 2 RECLOCKER LOCKED This Green LED will be On when reclocker 1 is locked to a valid signal present at the module input...

Page 8: ...ER PRESENT This Green LED will be On when cable equalizer 2 detects that there is a signal present at input 2 270 Mb s This Green LED will be On when reclocker 2 is locked to a valid SMPTE 259M C 270 Mb s SDI signal 1 5 Gb s This Green LED will be On when reclocker 2 is locked to a valid SMPTE 292M 1 5 Gb s HD SDI signal RECLOCKER BYPASS This Green LED will be On when reclocker 2 is in the bypass ...

Page 9: ...umper Locations 5 1 SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED BY THE GLOBAL FRAME STATUS The FRAME STATUS jumper J1 located at the front of the module determines whether local faults as shown by the Local Fault indicator will be connected to the 500FR frame s global status bus FRAME STATUS To monitor faults on this module with the frame status indicators on the power supply s FRAME STATUS L...

Page 10: ...44M 540 Mb s or DVB ASI video signals or as a non reclocking distribution amplifier with other data rates J2 controls the bypass for reclocker 1 and J5 controls the bypass for reclocker 2 BYPASS SELECT To operate the module in reclocking mode install the jumper in the RECLOCK position The RATE jumper associated with the respective reclocker must be set to match the signal being reclocked To operat...

Page 11: ...at the configuration has been carried out There are 3 components of SNMP 1 An SNMP manager also known as a Network Management System NMS is a computer running special software that communicates with the devices in the network Evertz VistaLINK Pro Manager graphical user interface GUI third party or custom manager software may be used to monitor and control Evertz VistaLINK enabled products 2 Manage...

Page 12: ...A 3G Monitor Status Tab 6 2 1 Lock Status Monitor Settings Monitor Settings Lock Status Locked Not Locked Displays the current status of the video input reclocker 6 2 2 Bypass Select Monitor Settings Monitor Settings Bypass Select Reclocked Bypassed Displays the operating state of the video input reclocker Page 10 Revision 2 0 ...

Page 13: ...tor Settings Input Video Rate Not Valid 270M 1 5 Gbs 3 0 Gbs Displays the detected input video rate 6 3 Fault Traps Tab Figure 6 2 VistaLINK 500DA 3G Fault Traps Tab 6 3 1 Module OK Trap Status Fault Traps Trap Status Module OK Indicates the current status of the module same state as Module Fault LED Revision 2 0 Page 11 ...

Page 14: ...Frame Manual 500DA2Q 3G 3G HD SD SDI Dual Reclocking Distribution Amplifier This page left intentionally blank Page 12 Revision 2 0 ...