2400PSUA-8 - Eight Channel 240xLT/LR DC Power Supply
Revision 1.2
Page
5
2.1. 2400PSUA-8 CONNECTIONS
AC IN 1+2:
100 to 240 VAC, 50/60 Hz, auto-ranging AC inputs. Each input is separately connected
to one of the internal, redundant AC/DC power supplies. The dual connectors should be
connected to separate AC branch circuits to permit fully redundant power.
Two outdoor rated cable assemblies with mating connectors are included. Cables are
available with NEMA5-15P, as well as UK or Schuko style connectors for worldwide
applications.
CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK, EARTHING OF THE
EARTH PIN OF THE MAINS PLUG MUST BE MAINTAINED
For 2400PSUA-8-WP units installed outdoors, unconnected AC input
connectors must be protected by attaching the captive sealing caps
(received with the unit) in order to prevent moisture ingest into the unit.
Observe local electrical codes.
DC Outputs:
Eight output F-Type connectors for DC power connections to 240xLT/LR’s. Each output
features active short-circuit and overload protection.
For 2400PSUA-8-WP units installed outdoors, unconnected DC ouput
connectors must be protected by attaching the captive sealing caps
(received with the unit) in order to prevent moisture ingest into the unit.