background image

Mounting the HSP01 

 
The PIR Detector is suitable for mounting in dry interior locations only. 
 
The recommended position for a PIR Detector is in the corner of a room mounted at 
a height between 1.8 and 2m. At this height, the detector will have a maximum 
range of up to 10m with a field of view of 110

°

  and the position of the PCB set at 5.   

The position of the PCB inside the PIR can be set to 5 different positions to adjust 
the range of the detector. Setting the PCB in position 3 will reduce the range to 
approximately 6m, with position 1 providing a range of approximately 3m. The 
recommended position for the PCB is position 5. 
 
 
 

PCB Position 

Range 

 

1 3m 

 

3 6m 

 

5 9m 

 
 
 
 
 
When considering and deciding upon the mounting position for the detector, the 
following points should be considered to ensure a trouble free operation: 
 
1.  Do not install the detector facing a window, exposed to or facing direct sunlight. 

PIR Detectors are not suitable for use in conservatories. 

 
2.  Do not install the detector exposed to ventilators or above a heat source (e.g. 

fire, radiators, boilers) 

 
3.  Where possible, mount the detector in the corner of the room so that the path of 

an intruder would cut across the fan detection pattern. PIR detectors respond 
more effectively to movement across the device than to movement directly 
towards it. 

 
 
 
 
 
                                      Less Sensitive                                More Sensitive 
 
5.    Do not install the detector in a position where it is subject to excessive vibration. 

 
6.  Ensure that the position selected for the PIR Detector is within effective range of 

the system (please refer to the Troubleshooting section). 

 

Note

: When the system is armed, household pets should not be allowed into an 

area protected by a PIR Detector as their movement would trigger the PIR and 
generate an alarm. 

Installation 

 

1.  Using a 3mm drill, carefully drill out the required mounting holes in the rear 

cover according to whether the unit is being mounted in a corner or against a 
flat wall. 

 

Note:

 Drill 1

st

 mounting hole positions to fulfill corner mounting installation, and 

2

nd

 mounting hole positions for flat wall installation. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

Corner mounting

   

 

 

 
 
 
 
 
3.  Using the rear cover as a template, mark the positions of the fixing holes on the 

wall. 

 
4.  Fix the rear cover to the wall using the two 18mm No.4 screws and 25mm wall 

plugs (a 5mm hole will be required for the wall plugs). Do not over-tighten the 
fixing screws as this may distort or damage the cover. 

 
5.  Check that the detector PCB is located and set in the correct position to provide 

the required detection range. To adjust the PCB position, simply slide it up or 
down ensuring that the location legs are aligned with the required position 
number marked on the board. 
 

6.  Refit the detector to the rear cover and locate the clips in the top edge into the 

rear cover. Push the lower edge of the detector into place and refit the fixing 
screw in the bottom edge of the detector to secure in position. Do not 
over-tighten the fixing screws as this may damage the casing. 

 

Summary of Contents for HSP01

Page 1: ...sys Product Overview LED Indication Red LED Used to indicate trigger events low battery power and warm up Green LED Used to indicate key learning controls Orange LED Used to indicate no codes learned Binding with Homesys 1 Undo and remove the fixing screw from the bottom of the detector Carefully pull the bottom of the detector away from the rear cover and then slide down to release the top clips ...

Page 2: ...ning procedure is completed The screen below will appear indicating the process is successful 4 If after 30 seconds the LED flashes rapidly with an interval of 0 1 second for 3 times it means the PIR failed the binding process Operation Testing Warm Up It will take approximately 2 minutes to warm up the Detector after a battery is inserted During this period the LED will flash red slowly When the ...

Page 3: ...n a position where it is subject to excessive vibration 6 Ensure that the position selected for the PIR Detector is within effective range of the system please refer to the Troubleshooting section Note When the system is armed household pets should not be allowed into an area protected by a PIR Detector as their movement would trigger the PIR and generate an alarm Installation 1 Using a 3mm drill ...

Page 4: ... mounting height 25 C Operating Frequency 868MHz EU 923MHz America Specifications are subject to change without notice WARNING Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities instead Please contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps haz...

Page 5: ...y responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter www everspring com 3F No 50 Sec 1 Zhonghua Rd Tucheng Dist New Taipei City 23666 R O C ...

Reviews: