3. Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default
Description
1 True
Period
1
0-120
100ms
10
10*100ms=1second
0: Disable
2 Send
Basic
Command to
Group 2
1 0,1
0 0:Disable
1:Enable
3 Meter
Report
Period
2 0-3240
(9Hr)
10s 3
3*10=30seconds
0:Disable
3-1 The true period:
If the setting is configured for 1 second, pressing On or Off button alternately
within 1 second will not send out RF command. After 1 second has elapsed, it
will examine if current On/Off state is the same as the initial 1 second. If the
same, no RF command will be sent, whereas if it is different, RF command will be
sent to update the status. The maximum interval is 12 second
(100ms*12=12000ms).
3-2 Send basic command to grouping 2:
If the setting is configured for 0, whenever pressing On/Off button manually on the
Module or receiving basic_set command from the Z-Wave Controller, the Module
will not send command to other devices of Grouping 2 for On or Off operation;
whereas if the setting is configured for 1, the Module will send command to other
devices of Grouping 2 for On or Off operation.
3-3 Meter Report Period:
If the setting is configured for 30 seconds, the Module will report its instant power
consumption every 30 seconds to Z-Wave Controller. The maximum interval to
report its instant power consumption is 9 hours (10s*3240/3600=9hr).
4. Meter Command Class
The Module will report its instant or accumulated power consumption to Z-Wave
Controller. If the calculation of accumulated power consumption is needed, the
Z-Wave Controller needs to be sent Meter Reset Command to the Module,
enabling to reset to zero.
4-1 Instant Power Consumption of Module
When receiving Meter Get Command, it will report Meter Report Command to
the node of Grouping 1.
Meter Get Command:
[Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command:
[Command Class Meter
,
Meter Report
,
Rate
Type+Meter Type
,
PrScale+ Size
,
Meter Value 1
,
Meter Value 2]
Rate Type = 0x01
Meter Type = 0x01
Precision = 0
Scale = 0x02(W)
Size = 2 Bytes (Meter Value)
Meter Value 1 = High Byte (W)
Meter Value 2 = Low Byte (W)
Example:
Meter Value 1 = 0x01(W)
Meter Value 2 = 0xF4(W)
Meter (W) = Meter Value 1*256 + Meter Value 2 = 500W
4-2 Accumulated Power Consumption(KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
the node of grouping 1.
Meter Get Command:
[Command Class Meter, Meter Get, Scale = 0x00
KW/h)]
Meter Report Command:
[Command Class Meter
,
Meter Report
,
Rate Type + Meter Type
,
Pr Scale + Size
,
Meter Value 1
,
Meter Value 2
,
Meter Value
3,
Meter Value 4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x00 (KWh)
Size = 4 bytes (Meter Value)
Meter Value 1 = (W) MSB
Meter Value 2 = (W)
Meter Value 3 = (W)
Meter Value 4 = (W) LSB