The AD132-1 Lamp Module is a transceiver which belongs to the member of UNet

 

series and is fully compatible with any UNet enabled devices.  It is designed to 
control the On/Off status and brightness level of incandescent lamp connected to 
the lamp module.    When setting to On, it will detect the connected load wattage, 
thus ensuring safety and security.    For instance, when overload occurs, the Lamp 
Module will be disabled of which LED will flash rapidly for 30 seconds.  Unplug 
and re-connect the plug will restore the Lamp Module to Off status. 
   

Initial Power Up & Installation 

 
1. 

Plug this Lamp Module into a wall outlet near the load to be controlled.    The 
LED on the Module will be flashing slowly.  This implies that the Module 
does not memorize any ID code and cannot work with UNet enabled devices. 

 
2. 

Plug the appliances into the Lamp Module. There are two outlets at different 
sides of AD132-1. The appliances plugged into the controllable outlet can be 
controlled by the On/Off button and remote controller, the other side is 
non-controlled and acts as a pass-through outlet. Make sure the total load of 
both sides cannot exceed 1500 watts which means if the load of controllable 
outlet is changed, the other side will be altered accordingly. 

 

For instance, if the load of controllable outlet is about 1500 watts, the other 
should be 0 watt; while if the load of controllable outlet is 1200 watts, the 
other should be 300 watts. 

 
3. 

Turn the button or switch on the load to the ON position 

 
4. 

To manually turn ON the AD132-1 Lamp Module, press and release the 
On/Off button. The indicator LED will turn ON, and the load plugged into the 
AD132-1 Lamp Module will also turn ON. 

 
5. 

To manually turn OFF the AD132-1 Lamp Module, simply press and release 
the On/Off button. The indicator LED will turn OFF and the load plugged into 
the AD132-1 Lamp Module will also turn OFF. 

 
6. 

To let AD132-1 work and communicate with the device of UNet network, it is 
essential that the same ID essential that the same ID code is used between 
Lamp Module and UNet enabled device.  For more details about how 
AD132-1 learns ID code of UNet device, please refer to the section of ID 
code learning. 

 

Note:

 The Module’s detection can only become precisely after 30 minutes for the 

first time of plug-in to the electrical outlet, however during this 30 minutes it won’t 
hinder its normal operation (e.g. learn, clear the ID code and On/Off control). 

Learning the ID Code 
 

1.  In the front cover, there is an On/Off/Dim button with LED indicator (Fig. 1).   

 

 
 
 
 
 
 
 

Fig. 1

 

     

Note: 

This On/Off/Dim button serves as a gateway to learn and clear the ID 
code. 

 
2.  Keep pressing the button for 3 seconds until the LED flashes rapidly.  A 

30-second countdown will start.    The Module is about to learn the ID code. 

 
3. Using 

UNet

 

enabled device to emit the ID code to the Module.  Press and 

hold the “learning” button of UNet device more than 3 seconds, so as to emit 
the ID code to the Module. 

 
4.  If the Module learns the ID code properly, the LED indication will be on for 1 

second then turn off. 

 
5.  When the LED flashes rapidly for 3 times, it is ascribed to the following two 

conditions: 

i. 

The Module failed to learn the ID code. 

ii. 

After entering 30-second ID code learning mode, press the button       

 

again to exit the ID code learning mode.

 

 

Note:

 

Ú

 

At the step 2, if you happen to press the On/Off/Dim button for less than 3 
seconds, the Module will turn to “On” status (LED lights on steadily).  To 
re-enter the ID code learning mode, simply press the On/Off/Dim button to turn 
off the Module (LED lights off), and then repeat the above step 2-5 to complete 
ID code learning procedure. 

 

Ú

 

The ID code setting is stored in non-volatile memory and is not lost during   
power failures. It can be cleared by proceeding with ID code clearance as 
indicated below in ID code clearing section. 

 

Ú

 

The module can learn only one set of ID code. 

 