background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2

EVERSAN

EVERSAN, INC. • 34 Main Street, Whitesboro, NY 13492 • 1-800-383-6060 Fax: 315-736-4058

www.eversan.com

console on. If you are operating multiple scoreboards with one console you must power all the 

scoreboards prior to turning on the console. If you are operating multiple scoreboards with multiple 

consoles. You must turn power on to one scoreboard and then the console you want to use to 

operate that scoreboard. This allows each system to set automatically so as not to interfere with 

each other.

8.  Go to operating instructions to test scoreboard.

Installation Instructions

1.  It is recommended that a professional sign company be hired to install the scoreboard.  SEE 

DRAWINGS

2.  Eversan recommends a minimum depth of 5 ft. and a 2ft. footer diameter.

3.  Calculate the wind loading by standard formula for height and dimension of sign.

     

  NOTE:

 Check local codes for your area.

4.  Prepare and sink I-beams, W6 x 15 I-Beam conforming to ASTM A36 recommended minimum, 

align with plumb line and careful measurements.

5.  Determine height of lowest point for scoreboard.  Mark and align on all mounting beams parallel to 

visual ground sighting.

6.  Drill and bolt (3/8 hardened bolts) or weld provided bottom Z-brackets to the posts as shown in the 

installation diagram.

7.  Lift scoreboard set onto Z bracket. Secure temporarily with a clamp.

8.  Place the top Z-brackets on the board and install in the same manner as the lower.

9.  The board is now ready to be wired.

INSTRUCTIONS FOR WIRING

(See Installation Diagram)

Electrical Specifications:

 Electric outlets for scoreboards are always on a “clean” unused, switched 

breaker box. Pay close attention to the power source and connections. It is recommended that a 

key-switch or switched breaker box be used to turn off the system at the end of use each day. 

The 

scoreboard should always be powered down when not in use.

Power Requirement: 

120VAC @ 1 amp. Eversan, Inc. recommends using a 10-amp, GFCI, breaker 

for outdoor scoreboard power.  

Optional Battery:

 12VDC 7AH rechargeable battery may be purchased to use with this scoreboard. 

The four-pin round connector on the left side of scoreboard is the input for DC power.   

CAUTION: (Cabled System Only)

 

The data cable is a pre-wired, 2 conductor shielded, 22GA 

stranded cable. Any cable splicing should be color-coded or failure of the computer power supply will 

result. Continuity of the shield is essential in reducing possible damage due to lightening.

.

Operating Instructions

Setting the Time

: To set the time the clock must be stopped. Press and release the TIME button 

Summary of Contents for 9665

Page 1: ...MODEL 9665 HOCKEY SCOREBOARD Instruction Manual Address 34 Main Street Whitesboro NY 13492 Phone 315 736 3967 Toll Free 800 383 6060 Fax 315 736 4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS W...

Page 2: ...www eversan com Table of Contents Check List 1 Out of Box Setup and Test 1 Installation Instructions 2 Wiring Instructions 2 Operating Instructions 3 Maintenance of Outdoor Scoreboards 4 Removal and...

Page 3: ...installation Warranties will be void if the procedures below are disregarded Failure to test scoreboard prior to hanging will void all warranties 1 Plug wall junction box cable Optional or Data cable...

Page 4: ...olts or weld provided bottom Z brackets to the posts as shown in the installation diagram 7 Lift scoreboard set onto Z bracket Secure temporarily with a clamp 8 Place the top Z brackets on the board a...

Page 5: ...nter player 23 with 1 minute 30 second penalty time enter 2 3 0 1 3 0 Only the last three digits of the penalty time will be displayed on the scoreboard The system will automatically keep track of up...

Page 6: ...should NOT be left in the Recharging mode for more than 24 hours as this can damage the cell CAUTION DO NOT attempt to charge this battery pack on currents other than 60 cycles 110volt 120volt AC curr...

Page 7: ...d test scoreboard If problem persists please contact Eversan Inc Removing the Power Supply Box in the front of the scoreboard 1 Remove the access panel s four 8 32 screws from the top and bottom of th...

Page 8: ...n ohmmeter to check if it is blown 6 If the fuse is blown replace it with a 250 volt 1 amp fuse and reinstall fuse cap and power supply cover Lazy Segments 1 If a lazy segment is detected and you are...

Page 9: ...Page 7 EVERSAN EVERSAN INC 34 Main Street Whitesboro NY 13492 1 800 383 6060 Fax 315 736 4058 www eversan com OFF ON ON OFF...

Page 10: ...Page 8 EVERSAN EVERSAN INC 34 Main Street Whitesboro NY 13492 1 800 383 6060 Fax 315 736 4058 www eversan com OFF ON ON OFF...

Page 11: ...ersan com MODEL 9665 HOCKEY SCOREBOARD Address 34 Main Street Whitesboro NY 13492 Phone 315 736 3967 Toll Free 800 383 6060 Fax 315 736 4058 SCOREBOARDS TIMERS MESSAGE SIGNS VIDEO DISPLAYS WIRELESS EV...

Page 12: ......

Reviews: