![EverMore GM-X205 User Manual Download Page 30](http://html.mh-extra.com/html/evermore/gm-x205/gm-x205_user-manual_2444189030.webp)
EverMore Technology Inc.
2F, No.7, R&D Road 1, Science-Based Industrial Park, Hsinchu, Taiwan, 310, R.O.C.
http://www.emt.com.tw
30
4.3.2 Data Logging Output Messages
4.3.2.1 LogData
Purpose
When the
LogData Dump
command is sent to the receiver to retrieve the logged data in
binary format, each logged record is send out according to the format listed below with header
and footer described in section 4.2 added. The logged data is output consecutively until all
data stored in the on-board memory is sent out.
Format
Byte #
Contents
Range
Size
Unit
1
Message ID = 0x22
Unsigned byte
2 ~ 3 Velocity
mode[13]
DGPS[12]
velocity[9:0]
Unsigned 16bit integer
4 ~ 7 GPS Time
GPS week [31: 20]
GPS tow [19: 0]
Unsigned 16bit integer
8 ~ 11 EFEC_X
+/- 2^31
Signed 32bit integer
meter
12 ~ 15 EFEX_Y
+/- 2^31
Signed 32bit integer
meter
16 ~ 19 EFEC_Z
+/- 2^31
Signed 32bit integer
meter
mode
: Navigation mode ( 0=2D, 1=3D )
DGPS
: 0 = no DGPS used, 1 = used DGPS correction
velocity[9:0]
: velocity in m/s, range 0 ~ 1023
ECEF_X
: ECEF coordinate X axis
ECEF_Y
: ECEF coordinate Y axis
ECEF_Z
: ECEF coordinate Z axis
4.3.2.2 LogConfig Info
Purpose
When
LogConfig Read
or
LogConfig Set
command is sent to the receiver, data logging
configuration and percentage of the data buffer usage are returned.
Format
Byte #
Contents
Range
Size
Unit
1
Message ID = 0x20
Unsigned byte
2 ~ 3 Buffer Used Percentage 0 ~ 10000
Unsigned 16bit integer
0.01%
4 ~ 5 Configuration
1 = log data
0 = stop logging data
Unsigned 16bit integer
6 ~ 7 delta_Tmin
0 ~ 65535
Unsigned 16bit integer
Sec
8 ~ 9 delta_Tmax
0 ~ 65535
Unsigned 16bit integer
Sec
10 ~ 11 delta_D
0 ~ 65535
Unsigned 16bit integer
meter