12
EVERLAST
Introduction and Specifications
Section 1
PowerMaster Combination Units
Table 1.1
MODEL
PowerMaster 226
PowerMaster 205
INPUT
Voltage
AC220/230/ 240V 50Hz
Open Current Voltage
60 - 80V
AC
Base Current Range
20~220A
20~200A
AC balance Control
30%~70 %
TIG
AC Frequency Control
20~100Hz
Rated Duty Cycle
60%
Pulse Current Range
5~220A
5~200A
Rated Duty Cycle
60%
DC
Current Down-slope Timer
0~10S
Base Current Range
5~220A
5A~200A
Pulse Width Ratio
0.1~0.9
TIG
Pulse Frequency
0.5~25Hz
After Flow Time
1~25s
Arc Starting Method
High Frequency
Open Current Voltage
60 - 80V
DC
Base Current Range
5~180A
5~160A
MMA
Rated Output Current
180A
160A
Rated Duty Cycle
60%
CUT
Cutting Current Range
20A~60A
20~50A
Rated Duty Cycle
60%
Arc Starting Method
Pilot Arc
Efficiency
≥
80%
Mass
55 lbs (25kg)
Protection Class of enclosure
IP21S
Dimensions
17x8x11.5 inches (430x200x290 mm)
Summary of Contents for POWER DIGITAL SERIES
Page 30: ...30 EVERLAST EVERLAST...