Fire Safety

•  Refer to your local authority for guidelines and requirements for 

building or structural fire safety.

•  The roof construction and installation may affect the fire safety of 

a building; improper installation may contribute to hazards in the 
event of fire.

•  For roof application, the panels should be mounted over a fire 

resistant covering rated for the application.

•  It may be necessary to use components such as earth ground 

fault circuit breakers, fuses and circuit breakers.

•  Do  not  use  panels  near  equipment  or  locations  where  flammable 

gases can be generated or can collect.

Electrical Installation

•  Avoid all electrical hazards when installing, wiring, operating and 

maintaining a panel.

•  If the total DC system voltage exceeds 100V, the system must be 

installed, commissioned and maintained by a qualified professional, 
in accordance with local requirements.

•  Contact with a DC voltage 30V or more is potentially hazardous.
•  Do not use panels of different electrical or physical configurations 

in the same system.

•  The  maximum  open  circuit  voltage  of  the  system  must  not  be 

greater than the specified maximum system voltage for the panel.

•  All Evergreen Solar panels are equipped with factory-installed wires 

and  quick  connectors.  Panels  have  been  designed  to  be  easily 
interconnected in series.

•  Evergreen  Solar  ES-A  series  panels  are  equipped  with  Multi-

Contact

®

  Type  4  clickable  connectors.    In  order  to  comply  with 

the  2008  National  Electric  Code  for  accessible  arrays,  the  plug 
connection  must  be  secured  with  the  UL  approved,  pluggable 
safety lock clip (PV-SSH4) supplied by Multi-Contact

®

.

•  The  PV-SSH4  clip  is  not  provided  by  Evergreen  Solar  and  must 

be  purchased  separately.    Once  the  clip  is  installed,  the  PV  plug 
connection can only be unlocked with the use of the PV-MS tool, 
also supplied by Multi-Contact

®

.

•  Evergreen Solar ES-A series panels are also equipped with 10AWG, 

UL4703 certified PV-WIRE which enables the panels to be used in 
electrically ungrounded systems with transformer-less inverters.

•  Use system wiring with suitable cross-sectional areas and connectors 

that are approved for use at the maximum short-circuit current of 
the panel.

•  Match  the  polarities  of  cables  and  terminals  when  making  the 

connections; failure to do so may result in damage to the panel.

•  When  reverse  currents  can  exceed  the  value  of  the  maximum 

protective fuse marked on the back of the panel, a properly rated 
and certified over-current device (fuse or circuit breaker) must be 
connected in series with each panel or string of panels.

•  The rating of the over-current device shall not exceed the value of 

the maximum protective fuse marked on the back of the panel.

•  The panel contains factory installed bypass diodes located inside 

the junction box.

•  The junction box is not designed or certified to be field accessible 

or  maintainable  and  should  under  no  circumstances  be  opened. 
Opening the junction box may void the warranty.

•  Panels with a suspected electrical problem should be returned to 

Evergreen Solar for inspection and possible repair or replacement 
as per the warranty conditions provided by Evergreen Solar.

MC

®

 is a registered trademark of Multi-Contact AG

Grounding

•  Panel frames should be connected to an earth ground for safety 

and protection from lightning.

•  The  panel  frame  is  provided  with  grounding  holes  that 

accommodate self-tapping screws. If grounding holes are utilized, 
a #10-32 stainless steel thread cutting screw is required.  

•  The following specific grounding methods utilizing thread cutting 

screws  have  been  successfully  tested  with  ES-A  panels  to  the 
UL1703 standard.  This does not prohibit the use of other methods, 
providing that all applicable codes and standards are met.

Device 

Part No. 

Material 

Bonding Method to Frame

ILSCO 

GBL-4DBT  Tin plated 

• 10-32 cutting screw at

lay-in lug   

copper  

  grounding hole locations.

Tyco 

SolKip 

Copper alloy  • The use of a nut is required 

lay-in lug  1954381-1  plated with    behind the screw to create 

 

 

tin over  

  a positive means of 

 

 

nickel 

  attachment to the frame.

 

 

 

• 10-32 cutting screw at

 

 

 

  grounding hole locations.

Cutting 

 

 

• The use of a nut is required

screw with   

 

  behind the screw to create

3 washers  N/A 

Stainless 

  a positive means of

(2 cupped,   

steel 

  attachment to the frame.

1 star) 

 

 

• The grounding wire must be 

 

 

 

  placed between 2 cupped 

 

 

 

  washers and around the  

 

 

 

  10-32 cutting screw.

 

 

 

•  A star washer is required 

between the panel 

frame and the cupped 

washer to ensure that the 

frame anodized layer is 

penetrated.

•  Evergreen panels can also be grounded using third party 

grounding washers or clip devices provided the devices are 
listed and identified for grounding the metallic frames of PV 
panels and the devices are installed in accordance with the 
manufacturer’s specified instructions.

Mechanical Installation

•  Panels should be mounted to maximize direct exposure to sunlight 

and to eliminate or minimize shadowing.

•  Even partial shadowing can substantially reduce panel and system 

output.

•  Panels  must  be  securely  fastened  using  support  frames  or 

mounting kits specialized for PV applications.

•  Panels may be mounted at any angle from vertical to horizontal 

orientation.

•  Care must be taken to avoid low tilt angles which may cause dirt to 

build-up on the glass against the frame edge.

•  Dirt build-up on the surface of the panel can cause active solar 

cells to be shaded and electrical performance to be impaired. 

•  Contact Evergreen Solar for more information regarding minimum 

recommended tilt angles for specific panel products.

•  For  roof  mounted  systems,  provide  adequate  rear  ventilation 

under a panel for cooling (100mm: 4 in. gap minimum).

•  Clearance  of  7mm:¼  in  or  more  between  panels  is  required  to 

allow for thermal expansion of the frames.

•  Always keep the back surface of the panel free from any foreign 

objects or structural elements which could come into contact with 
the panel, especially when the panel is under mechanical load.

2 of 4

Valid from 1

st

 June 2009 / IM-ES-A_fa3_US_010609_ETL © 2009 Evergreen Solar, Inc.

ES-A Series Photovoltaic Panels - Black Frames

Safety, Installation and Operation Manual