68
Electrical System
Notice:
Circuit protection for other engines, controls,
and steering systems may be different. Refer
to the engine owner’s manual for information
on circuit protection and amperage require-
ments for the engines and control systems
on your boat.
Battery Switch Continuos Power Fuse Panel
Located in the battery switch panel. The fuses in
the panel protect the circuits for the remote bat-
tery switches that are always active and not turned
off by the battery switches. These continuous
power circuits are always supplied current when
the house batteries are connected.
The following are the circuits supplied and pro-
tected by fuses in the battery switch continuous
power fuse panel:
Port Battery
Protects the continuous power circuit for the
switch that activates the port engine battery
switch. This circuit is always supplied current
when the house batteries are connected.
STBD Battery
Protects the continuous power circuit for the
switch that activates the starboard engine battery
switch. This circuit is always supplied current
when the house batteries are connected.
House Battery
Protects the continuous power circuit for the
switch that activates the house battery switch.
This circuit is always supplied current when the
house batteries are connected.
EMER Battery
Protects the continuous power circuit for the
switch that activates the emergency parallel relay.
This circuit is always supplied current when the
house batteries are connected.
Spare
Reserved for additional 12 volt accessories.
Accessory Continuous Power Fuse Panel
Located in the battery switch panel. These fuses
protect the circuits that are always active and not
turned off by the battery switches. The continuous
power circuits are always supplied current when
the house batteries are connected.
The following are the circuits supplied and pro-
tected by fuses in the accessory continuous power
fuse panel:
Fwd Bilge
Protects the circuit for the automatic switch that
activates the bilge pump located in bilge below
the cabin sole. An LED light next to the FWD Bilge
switch in the helm switch panel will be lit whenever
the pump is activated.
Shower
C
ircuit for the automatic switch that activates the
shower and cabin drain sump pump located in the
forward bilge.
Aft 1
Protects the circuit for the automatic switch that
activates aft bilge pump 1 located in the bilge
below the systems compartment. An LED light
near the AFT Bilge switch will be lit whenever the
pump is activated.
Aft 2
Protects the circuit for the automatic switch that
activates the emergency bilge pump located in the
bilge below the systems compartment. An LED
light near the AFT Bilge switch will be lit whenever
the pump is activated.
Alarm
Protects the circuit for the automatic switch that
activates the high water alarm. The high water
alarm will sound to alert the operator of unusually
high water in the bilge.
Continuous Power Fuse Panels
Summary of Contents for 340 DC
Page 1: ...OWNER S MANUAL 340 DC...
Page 2: ...2 Revision 0 11 07 2018...
Page 14: ...14 NOTES...
Page 22: ...22 NOTES...
Page 25: ...25 Operation...
Page 86: ...86 NOTES...
Page 102: ...102 NOTES...
Page 122: ...122 NOTES...
Page 130: ...130 NOTES...
Page 149: ...149 MAINTENANCE LOG Appendix B Hours Date Dealer Service Repairs...
Page 150: ...150 Maintenance Log Hours Date Dealer Service Repairs...
Page 151: ...151 Maintenance Log Hours Date Dealer Service Repairs...
Page 152: ...152 Maintenance Log Hours Date Dealer Service Repairs...
Page 153: ...153 Maintenance Log Hours Date Dealer Service Repairs...
Page 154: ...154 Maintenance Log Hours Date Dealer Service Repairs...
Page 155: ...155 Appendix C BOATING ACCIDENT REPORT...
Page 156: ...156 Boating Accident Report...
Page 157: ...157 Boating Accident Report...
Page 158: ...158 NOTES...
Page 160: ...160 NOTES...
Page 167: ...CAUSE AND SOLUTION...