EverFocus FH 7517 EBL Installation & Operation Manual Download Page 2

FH7517EBL / FH7519EBL  Installation / Operation

 

 2 of 12 

Safety warnings 

 

Safety warnings 

  

 

To avoid any damage, please consider the following safety warnings: 

 

Never place the device near to heaters, furnaces, other heat sources or under direct solar irradiation.  

Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C.  

 

Make sure that the device‘s ventilation slots are not covered or sheeted. 

 

For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent. Do NOT use 
cleaning fluids based on alcohol, methylated spirit, or ammonia.  The glass plate has a hard surface coating to prevent 
scratches.  However, the use of strong chemical cleaning agents may damage this coating.  Use only a mild soap or 

detergent and water or specially formulated cleaners made for cleaning glass panels.  

 

Install the device only in dry and dustproof surroundings. Protect the device against any liquid‘s penetration. 

 

Avoid the penetration of any artefacts, e.g. through ventilation slots.  

 

Do not open the monitor yourself. In case of malfunction, contact your local installer or dealer. Unauthorized opening of 
the device will annul the warranty claim!   

 

Use only the original external power supply. 
 

 

WEEE:  

 
 

 
 
 

 

 

 

 

 FCC: 

 

 

 

 

 

 

 

 

 

 
 
 

 

 
 

ATTENTION!

  This is a class A product which may cause radio interference in a domestic 

environment; in this case, the user may be urged to take adequate measures. 

The information in this manual was current upon publication. The manufacturer reserves the right to revise and 

improve his products. Therefore, all specifications are subject to change without prior notice. Misprints reserved. 
Please read this manual carefully before installing and using this unit. Be sure to keep it handy for later reference.

 

Your EverFocus product is designed and 

manufactured with high quality materials and 

components which can be recycled and reused. 
This symbol means that electrical and electronic 

equipment, at their end-of-life, should be disposed 

of

 

separately from your household waste. 

Please, dispose of this equipment at your local 

community waste collection/recycling centre. 

In the European Union there are separate 

collection systems for used electrical and 
electronic product. 

Please, help us to conserve the environment we 

live in!

 

Ihr EverFocus Produkt wurde entwickelt und 
hergestellt mit qualitativ hochwertigen Materialien 

und Komponenten, die recycelt und wieder 

verwendet werden können. 

Dieses Symbol bedeutet, dass elektrische und 
elektronische Geräte am Ende ihrer Nutzungsdauer 

vom Hausmüll getrennt entsorgt werden sollen. 

Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen 
kommunalen Sammelstelle oder im Recycling 

Centre. 

Helfen Sie uns bitte, die Umwelt zu erhalten, in der 

wir leben

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following 
two conditions: (1) this device may not cause harmful interference, and (2) this device must 
accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation. 

NOTE:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B 
digital  device,  pursuant to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable  protection  against  harmful  interference  in  a  residential  installation.  This 
equipment generation, uses and can radiate radio frequency energy and, if not installed and 
used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio 
communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular installation. If this equipment does cause harmful interference to radio or television 
reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is 
encouraged to try to correct the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and 
receiver. 

 

Connect the equipment to an outlet on a circuit different 
from that to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician 
for help. 

 

Summary of Contents for FH 7517 EBL

Page 1: ...INSTALLATION OPERATION FH 7517 EBL 43cm 17 TFT Monitor with LED Backlight FH 7519 EBL 48cm 19 TFT Monitor with LED Backlight...

Page 2: ...ment at their end of life should be disposed of separately from your household waste Please dispose of this equipment at your local community waste collection recycling centre In the European Union th...

Page 3: ...INTRODUCTION 4 2 MAIN FEATURES 4 3 PACKAGE CONTENTS 4 4 CONNECTORS 4 5 INSTALLATION 5 6 FRONT KEYS 5 7 SETUP 6 7 1 Picture Setup 6 7 2 Sound Setup 7 7 3 OSD Setup 7 7 4 Picture in Picture Setup 8 7 5...

Page 4: ...D Comb Filter with De Interlace technology for clear color transitions and suppression of crosscolors Integrated 3D noise reduction filter Easy multi language OSD setup Picture size and position setup...

Page 5: ...ect other audio equipment active speakers headphone to the PC Audio output 4 Connect the 12VDC power supply to the DC input Use only the original power supply 5 Connect the power supply to 110 230 VAC...

Page 6: ...to set the brightness of the screen Press OR to adjust the parameter Contrast This is used to adjust the image contrast Press OR to adjust the parameter Tint Setup for Tint color tone Press OR to adju...

Page 7: ...e left or right Press OR to adjust the parameter H Zoom Adjust the H size of the display picture Press OR to adjust the parameter V Position Moves the display picture up or down Press OR to adjust the...

Page 8: ...e Selection of second video channel for PiP or PoP mode Press OR to select PC AV1 AV2 HDMI Signal Source Note It is not possible to combine AV1 and AV2 input in PiP or PoP mode Size Size of subwindow...

Page 9: ...240V 50 60Hz nominal power consumption 19W in standby 1 W Temperature Operation 0 40 C Storage 25 60 C not condensing Monitor MTBF 50 000 hours Humidity 10 90 Display resolution 1280x1024 Display area...

Page 10: ...FH7517EBL FH7519EBL Installation Operation 10 of 12 9 DIMENSION DRAWING FH 7517 EBL FH 7519 EBL...

Page 11: ...0p at 75Hz VESA 832 x 624p at 75Hz Apple Mac II 1024 x 768i at 87Hz IBM 1024 x 768p at 60Hz VESA 1024 x 768p at 70Hz VESA 1024 x 768p at 75Hz VESA 1280 x 1024p at 75Hz VESA 1152 x 870p at 75Hz Apple M...

Page 12: ...939495 Subsidiary Japan 5F Kinshicho City Building 2 13 4 Koto bashi Sumida Ku Tokyo 130 0022 Japan Tel 81 3 5625 8188 Fax 81 3 5625 8189 Subsidiary USA California 1801 Highland Ave Unit A Duarte CA...