![EverFocus EVS200A User Manual Download Page 39](http://html1.mh-extra.com/html/everfocus/evs200a/evs200a_user-manual_2443404039.webp)
EVS200A/EVS200AW
39
4.8.4 Serial Communication
Add Serial Communication setting.
-Channel 1 ID: This entry is used to assign channel 1 camera own ID code.
-Channel 2 ID: This entry is used to assign channel 2 camera own ID code.
-Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS485 port on the camera. There are six different speeds,
2400/4800/9600/19200/38400/57600. (Default: 9600)
-Protocol: Select protocol from EVF, Pelco-D, Pelco-P, Samsung and Panasonic.
(Default: Pelco-D)
-Data Bit: This field is the data bit at which you will be transferring. There are two
settings for this option: 8 or 7. (Default: 8)
-Stop Bit: This field is to set the stop bit for the RS485 connection. There are two
different stop bits, 1 or 2. (Default: 1)
-Parity: This field is to select the parity level at which you will be connected. You can
choose between None, Odd, or Even parity levels. (Default: none)