54
(diagram 3.21)
When a mask setting is completed, you will see “GO” displayed behind the mask
number. For example: MASK1 GO
<┘
.
User can turn the joystick Left/Right to
change the status of preset mask, including Go, Clear and Set.
Examples:
MASK1 GO
<┘
: press Enter key to go to this preset mask position.
MASK1 CLEAR
<┘
: press Enter key to clear this preset mask.
MASK1 SET
<┘
: press Enter key to start setting this mask.
OFF: disable tracking mask function.
d. RESUME TIME (S)
Turn the joystick Left/Right to change Resume Time. User may manually operate PTZ
function of this camera when auto tracking function is on. When manual operation
ceases, the system will resume to “auto tracking start point” after this time. Available
range is from 1 to 60 sec.
e. IDLE TIME (S)
Turn the joystick Left/Right to change Idle Time. When tracking object can no longer be
tracked in the range, the system will resume to “auto tracking start point” after this time.
Available range is from 1 to 60 sec.
f. SET OBJECT SIZE
User can set sizes of MAX and MIN frames here and the system will only track object
with size between MAX and MIN frames. Press Enter key of keyboard or turn joystick
Left/Right to enter object size setting mode (see diagram 3.22).There will be two frames
on the screen: MAX and MIN. Press IRIS+ key of keyboard to select MAX/ MIN frame
TRACKING MASK 1 POSITION
IRIS+/IRIS-: JOYSTICK FOR
SET SIZE
TRACKING MASK 1 SIZE
IRIS-: JOYSTICK FOR PTZ
IRIS+: SAVE AND RETURN