95
4.10.4 I/O Control
Figure 4-40 is a screenshot of the I/O Control Setting Menu. This menu is used to define the settings for
controlling the DVR through RS485, and for DVR control of attached PTZ cameras.
Figure 4-40 System Menu – I/O Control
RS232
Baud Rate:
This field is to set the speed at which is used to transmit instruction or information through the
RS232 port on the DVR. There are eight different speeds: 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS,
19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit:
This field is the data bit at which you will be transferring. There are two settings for this option: 8
or 7.
Stop Bit:
This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2.
Parity:
This field is to select the parity level at which you will be connected. You can choose between None,
Odd, or Even parity levels.
RS485
PTZ Protocol:
Select PTZ protocol
,
choose from the following protocols: Transparent, Pelco D, Pelco P,
Everfocus, or Samsung. (NOTE: all cameras on the bus must use the same protocol)
485 ID:
This is the ID used by the EKB500 to send commands to the DVR. On an RS485 connection, every
device (PTZ, DVR and controller) must be assigned a unique ID number between 0 and 127.
Summary of Contents for ECOR2
Page 44: ...36 Figure 3 8 Search Menu Snapshot Search result ...
Page 64: ...56 ...
Page 114: ...106 ...