5.

 

Pulse Control:   

Once or twice   

PULSE 

                  1   

 

 

 

                  2                                       

 

 

4 PINS 2 PAIRS w/Jumper connector

 

Position 1: Set to "ONCE" for instant reaction when PIR 

detects movement, the connected device/alarm 

will be triggered immediately. 

Position 2: Triggering will start after the PIR detects 

movement twice within 15 seconds. 

6.

 

Terminals: 

             

N.C        N.O      --    + 

         

                                                               

                                                     

 

 

       

N.C: Normally closed 

N.O: Normally open contacts 

Input power (see below) 

Relay output current: 2A 24VAC, 2A 24VDC 

7.

 

Power: 

12V DC

       

Standby current: 1mA 

                              Working current: 25mA 

8.

 

Caution: 

Do not place in direct sunlight or reflected sunlight. 

 
 

Jumpers and wiring terminals of PIR Detector: 

 

                                                                                OUTPUT TERMINALS 

                                                                            N.C            N.O       

--

      + 

PULSE 

COUNT 

                                                                                                                                JP2 

                                                  PULSE 

                                            1 

                                            2 

                                                                J2                                               

LED 

LIGHT CONTROL                                                                                                                                             

SELECTOR 

RECORDING CONTROL 

                                                                                                                                           

 

TIME

 

ADJUSTMENT                                                                                                                                                                     

J1 

                              VR2                    J4                              VR1                       

 

Summary of Contents for ECMD200

Page 1: ...interfere with camera operation 2 Never disassemble the camera beyond the recommendations in this manual nor introduce materials other than those recommended herein Improper disassembly or introducti...

Page 2: ...ended 8 Mounting Use care in selecting a solid mounting surface which will support the weight of the camera plus any wind snow ice or other loading and securely attach the camera to the mounting surfa...

Page 3: ...ide Dynamic Range DWDR 2D Noise Reduction 2DNR DC power cable and video cable and power pigtail provided Built in anti aliasing function to improve perceived video image quality PIR Motion Detector PI...

Page 4: ...3 DIMENSIONS...

Page 5: ...ng Temperature 10 C to 50 C 14 F to 122 F Humidity 20 80 non condensing Power Requirements camera only 12VDC regulated 100mA PIR Motion Detector PIR Detection Angle Horizontal 100 Vertical 45 PIR Dete...

Page 6: ...s and insert plastic anchors into holes after drilling If wires will be hidden drill a minimum 5 8 diameter hole for the power and video cables Open the PIR detector casing by gently pulling the front...

Page 7: ...r PCB NOTE If the bracket is NOT used there is no way to change the camera direction aim the camera 5 If you are using the mounting bracket recommended attach the bracket to the mounting surface with...

Page 8: ...LED selector as indicated in A To determine the time period of N C N O relay to the alarm panel device A Max time Turn counter clockwise B Min time Turn clockwise 3 Dwell Time Adjustment MIN MAX VR2...

Page 9: ...s movement twice within 15 seconds 6 Terminals N C N O N C Normally closed N O Normally open contacts Input power see below Relay output current 2A 24VAC 2A 24VDC 7 Power 12V DC Standby current 1mA Wo...

Page 10: ...3 5625 8189 www everfocus co jp info everfocus co jp EverFocus Europe UK Unit 12 Spitfire Business Park Hawker Road Croydon Surrey CR0 4WD UK TEL 44 20 8649 9757 44 845 430 9999 FAX 44 20 8649 9907 ww...

Reviews: