8
5.
Pulse Control:
Once or twice
PULSE
1
2
4 PINS 2 PAIRS w/Jumper connector
Position 1: Set to "ONCE" for instant reaction when PIR
detects movement, the connected device/alarm
will be triggered immediately.
Position 2: Triggering will start after the PIR detects
movement twice within 15 seconds.
6.
Terminals:
N.C N.O -- +
N.C: Normally closed
N.O: Normally open contacts
Input power (see below)
Relay output current: 2A 24VAC, 2A 24VDC
7.
Power:
12V DC
Standby current: 1mA
Working current: 25mA
8.
Caution:
Do not place in direct sunlight or reflected sunlight.
Jumpers and wiring terminals of PIR Detector:
OUTPUT TERMINALS
N.C N.O
--
+
PULSE
COUNT
JP2
PULSE
1
2
J2
LED
LIGHT CONTROL
SELECTOR
RECORDING CONTROL
TIME
ADJUSTMENT
J1
VR2 J4 VR1