INSTALLATION 

 

Warning 

 

To prevent electrical shock, turn off the electrical power before making electrical 

connections. 

Drill the Holes 

1.

 

Locate a solid location which can bear the weight of the camera, and which is free of 

other electrical wires or other hazards. 

2.

 

Place the drilling template on the ceiling or wall 

3.

 

Drill 3 or 4 holes, 3 for mounting screws A, B and C, 1 for power/video cable if wires 

will be hidden. If surface wiring will be used, break out the thin area in the base to 

clear the wire opening. 

 

 

 

 

 

 

 

 

 

 

 

Remove the clear dome by twisting CCW about 1/8 turn and lift it off. Carefully disengage the 

black dome liner from the tabs on each side and lift it off.    Set these aside where they will not be 

damaged. 

 

Connect the camera power and video (observe polarity for power – connecting reverse polarity 

will damage the camera and void the warranty). Point the lens generally in the desired direction 

and attach the camera body to the mounting surface with the screws provided.   

Template 

Installation 

Screw 

Screw 

    Screw 

Mounting Holes 

Carefully cut or break away tab for surface wiring 

Summary of Contents for ECD360AV

Page 1: ...ds generated from these devices may distort the video image or otherwise interfere with camera operation 2 Never disassemble the camera beyond the recommendations in this manual nor introduce material...

Page 2: ...ing surface which will support the weight of the camera plus any wind snow ice or other loading and securely attach the camera to the mounting surface using screws and anchors which will properly supp...

Page 3: ...conceals viewing direction 3 Axis bracket for easy installation Built in Vari focal DC drive 3 5 8 5mm auto iris lens Excellent low light sensitivity of only 12 lux minimum illumination Employs Digit...

Page 4: ...lectronic Shutter NTSC 1 60s 1 100 000s PAL 1 50s 1 110 000s Gain Control Automatically White Balance ATW 2500 K 9500 K Gamma Characteristic 0 45 Lens Furnished 3 5 8 5mm F1 6 Vari Focal DC drive auto...

Page 5: ...be used break out the thin area in the base to clear the wire opening Remove the clear dome by twisting CCW about 1 8 turn and lift it off Carefully disengage the black dome liner from the tabs on ea...

Page 6: ...the camera module on its axis if necessary to align the image upright Loosen the lens adjusting screws and adjust the lens to obtain the desired field of view and focus Lock the lens and tilt screws R...

Page 7: ...21 Bandra Kurla Complex Bandra East Mumbai 400051 India TEL 91 22 6128 8700 FAX 91 22 6128 8705 www everfocus in UK Office Unit 12 Spitfire Business Park Hawker Road Croydon CR0 4WD London 0845 430 99...