background image

 

Clear Preset 

0xA0 

Address 

0x00 

0x05 

0x00 

Preset ID 

0xAF 

XOR 

Call Preset 

0xA0 

Address 

0x00 

0x07 

0x00 

Preset ID 

0xAF 

XOR 

Query Pan 

Position 

0xA0 

Address 

0x00 

0x51 

0x00 

0x00 

0xAF 

XOR 

Query Pan 

Position 

Response 

0xA0 

Address 

0x00 

0x59 

Value High 

Byte 

Value Low 

Byte 

0xAF 

XOR 

Query Tilt 

Position 

0xA0 

Address 

0x00 

0x53 

0x00 

0x00 

0xAF 

XOR 

Query Tilt 

Position 

Response 

0xA0 

Address 

0x00 

0x5B 

Value High 

Byte 

Value Low 

Byte 

0xAF 

XOR 

Query Zoom 

Position 

0xA0 

Address 

0x00 

0x55 

0x00 

0x00 

0xAF 

XOR 

Query Zoom 

Position 

Response 

0xA0 

Address 

0x00 

0x5D 

Value High 

Byte 

Value Low 

Byte 

0xAF 

XOR 

OSD MENU

 

 

OSD MENU

 

1. Press the MENU key on the IR remote controller, to enter the OSD menu as bellow: 

 
 2. After enter the main menu, use the navigate UP/DOWN key to select the main menu. Once selected, 
the main menu will change to blue background, and the right side will show all sub menu options.   
3. Press the navigate RIGHT key to enter sub menu; use UP/DOWN key to select the sub menu;  
use the LEFT/RIGHT key to select parameter. 
4. Press the MENU key again to return to previous menu. Press the MENU key continuously to exit the 
OSD menu. Before exit you are asked to save all settings (use LEFT/RIGHT key to set). As bellow: 
 

25 

WWW.EVERETIMAGING.COM 

Summary of Contents for EVP230

Page 1: ...EVERET EVP230 FHD PTZ Video Camera 30X zoom User Manual Version V1 0 English ...

Page 2: ...R REMOTE CONTROLLER 9 VISCA IN RS232 PORT 11 VISCA PROTOCOL 13 PART1 CAMERA RETURN COMMAND 13 PART2 CAMERA CONTROL COMMAND 13 PART3 CAMERA CONTROL COMMAND 19 VISCA PAN TILT ABSOLUTE POSITION VALUE 22 VISCA PAN TILT SPEED VALUE 22 PELCO D PROTOCOL COMMAND LIST 23 PELCO P PROTOCOL COMMAND LIST 24 OSD MENU 25 OSD MENU 25 IP ADDRESS SETTING 30 WEB SETTINGS 30 HOW TO UPDATE 34 VISCA OVER IP 36 HOW TO U...

Page 3: ...er For any service please contact authorized Everet technicians 9 Video cable and control cable should be individually shielded and cannot be substituted with other cables 10 Do not direct the camera lens towards strong light such as the sun or the intensive light 11 Use a dry and soft cloth to clean the camera housing Applied with neutral cleaning agent when there is need to clean To avoid damage...

Page 4: ...k all bellow items when open the package Camera 1 Power Adapter 1 Power Cable 1 RS232 Control Cable 1 USB 3 0 Cable 1 Remote Controller 1 QUICK START 1 Check all cable connections before power on 3 WWW EVERETIMAGING COM ...

Page 5: ...e 2 ON OFF Debugging mode 3 OFF ON Undefined 4 ON ON Working mode Dial Switch SW 3 SW 4 Instruction 1 OFF OFF reserve 2 ON OFF reserve 3 OFF ON reserve 4 ON ON reserve Dial Switch USB SW 5 SW 6 Instruction 1 OFF OFF Undefined 2 ON OFF Working mode 3 OFF ON Updating mode 4 ON ON Undefined 4 WWW EVERETIMAGING COM ...

Page 6: ...ocusing performance when zooming or moving Smooth PTZ mechanical design accurate pan tilt motor control 128 presets supported Standard Sony VISCA VISCA over IP PELCO P PELCO D control protocol IP VISCA over both TCP and UDP Daisy chain supported max 7 cameras connected in VISCA protocol Image flip function support upside down installation Supplied with functional IR remote controller Fast video fo...

Page 7: ...576p30 USB2 0 1024 576p30 960 540p30 640 360p30 512 288p30 Video Interface HDMI V1 4 3G SDI USB3 0 IP RJ45 Sensor CMOS sensor 1 7 12 4MP Zoom F5 8 203mm 35X F1 5 4 8 View Angle 60 Far 2 02 Near Rotation Angle Pan 170 170 Tilt 30 90 Rotation Speed Pan 0 120 s Tilt 0 80 s Preset Remote controller 10 RS232 128 Accuracy 0 1 Control Port RS232 RS485 USB3 0 RJ45 Network Speed 1000M Video encode H 264 H ...

Page 8: ...mp Exposure Auto Manual Bright Shutter Iris Focus Auto Manual Iris Auto Manual Electric Shutter Auto Manual Gamma Supported WDR Supported BLC Supported 2D Noise Reduction Supported 3D Noise Reduction Supported Anti Flicker OFF 50Hz 60Hz PanTilt Flip Supported Input Voltage DC12V POE Dimension 220mm 190mm 205 8mm Net Weight 1 5KG 7 WWW EVERETIMAGING COM ...

Page 9: ...Panel 4 Power Indicator Light 5 Dial Switch 6 Tripod Screw Hole 7 Installation Hole 8 RS232 control port input 9 RS232 control port output 10 HDMI port 11 3G SDI port 12 3 5mm Audio In 13 RJ45 port IP PoE 14 DC12V plug CAMERA DIMENSIONS 8 WWW EVERETIMAGING COM ...

Page 10: ... IR pass function Once press the IRT key the camera will receive and Pass the IR remote control signal to the codec terminal via VISCA IN port SET 1 SET4 ADDRESS SETTING Long press for 3 seconds until the key light ON to set camera address CAM1 CAM4 CAMERA SELECTING Short press to select the relative camera PRESET NUMBER KEY 1 9 Set preset long press 3 seconds the number key to set preset Run pres...

Page 11: ...SD AF Auto Focus MF Manual Focus RESET Press 3 seconds to reset camera MENU Enter OSD menu LEARN LIMIT L key Set the pan tilt left limit position LEARN LIMIT R key Set the pan tilt right limit position LEARN LMT CLR key Clear the limit position BLC OFF BLC ON Not Available BRIGHT BRIGHT Set image brightness only valid under bright priority exposure mode Video Format Keys Long press 3 seconds to se...

Page 12: ...4 GND 5 RXD 3 TXD 6 A 6 NC 7 IR OUT 7 NC 8 B 8 NC No V_IN V_OUT 1 DTR DTR 2 DSR DSR 3 TXD TXD 4 GND GND 5 RXD RXD 6 A 7 IR OUT 8 B VISCA IN RS485 6 A 7 IR OUT 8 B VISCA IN DB9 Connection Camera VISCA IN Windows DB 9 1 DTR 6 DSR 2 DSR 4 DTR 3 TXD 2 RXD 4 GND 5 GND 5 RXD 3 TXD 6 A 7 IR OUT 8 B 11 WWW EVERETIMAGING COM ...

Page 13: ...VISCA NETWORK SETUP SERIAL PORT CONFIGURATION Parameter Value Parameter Value Baud rate 2400 4800 9600 115 200 Stop Bit 1bit Start Bit 1 bit Check Bit None Date Bit 8 bit 12 WWW EVERETIMAGING COM ...

Page 14: ...ing the focus manually are received during auto focus PART2 CAMERA CONTROL COMMAND Command type function Command packet Note AddressSet Broadcast 88 30 01 FF Address setting IF_Clear Broadcast 88 01 00 01 FF I F Clear CommandCancel 8x 21 FF CAM_Power On 8x 01 04 00 02 FF Power ON OFF Off 8x 01 04 00 03 FF CAM_Zoom Stop 8x 01 04 07 00 FF Tele Standard 8x 01 04 07 02 FF Wide Standard 8x 01 04 07 03 ...

Page 15: ...igh Near Variable 81 01 04 08 3p FF p 0 Low to 7 High Direct 8x 01 04 48 0p 0q 0r 0s FF pqrs Focus Position Auto Focus 81 01 04 38 02 FF Manual Focus 81 01 04 38 03 FF One Push AF 8x 01 04 18 01 FF CAM_ZoomFocus Direct 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF pqrs Zoom Position 0 wide 0x4000 tele tuvw Focus Position CAM_WB Auto 8x 01 04 35 00 FF Indoor 8x 01 04 35 01 FF Outdoor 8x 01 04 35 02 FF One...

Page 16: ...ol CAM_Shutter Reset 8x 01 04 0A 00 FF Shutter Setting Up 8x 01 04 0A 02 FF Down 8x 01 04 0A 03 FF Direct 8x 01 04 4A 00 00 0p 0q FF pq Shutter Position 0 0x15 CAM_Iris Reset 8x 01 04 0B 00 FF Iris Setting 0 0xD Up 8x 01 04 0B 02 FF Down 8x 01 04 0B 03 FF Direct 8x 01 04 4B 00 00 0p 0q FF pq Iris Position 0 0x11 CAM_Gain Reset 8x 01 04 0C 00 FF Gain Setting 0 0x0F Up 8x 01 04 0C 02 FF Down 8x 01 0...

Page 17: ...izontal ON OFF Off 8x 01 04 61 03 FF CAM_PictureFlip On 8x 01 04 66 02 FF Image Flip Vertical ON OFF Off 8x 01 04 66 03 FF CAM_RS485Ctl On 8x 01 06 A5 02 FF Off 8x 01 06 A5 03 FF CAM_Saturation Saturation 8x 01 04 A1 00 00 0p 0q FF pq saturation level 0x00 0xff CAM_Contrast Contrast 8x 01 04 A2 00 00 0p 0q FF pq Contrast level 0x00 0xff CAM_SpeedByZoo m On 8x 01 06 A0 02 FF Off 8x 01 06 A0 03 FF C...

Page 18: ...0x03 1080P30 0x 04 1080P25 0x05 720P60 0x 06 720P50 0x07 720P30 0x08 720P25 0x09 1080P5994 0x0E 1080I5994 0x0F 1080P2997 0x10 720P5994 0x13 720P2997 0x14 1080P24 0x11 1080P2398 0x12 VideoSystem Set Sony 81 01 04 24 72 0p 0q FF pq Video format 1080P60 0x2e 1080P50 0x2f 1080I60 0x01 1080I50 0x04 1080P30 0x06 1080P25 0x08 720P60 0x09 720P50 0x0c 720P30 0x0e 720P25 0x11 1080P5994 0x13 1080I5994 0x02 1...

Page 19: ... to pq rs mn xy Gateway set 8x 01 04 AD 0p 0q 0r 0s 0m 0n 0x 0y FF Set gateway to pq rs mn xy Color adjust Color adjust OFF 8x 01 04 B6 00 FF Color adjust off Color adjust ON 8x 01 04 B6 01 FF Color adjust on brightness balance OFF 8x 01 04 B7 00 FF Keep Brightness brightness balance ON 8x 01 04 B7 01 FF No keep Brightness Flare red 8x 01 04 B8 dat FF Flare mode red value Default is 32 Flare green...

Page 20: ...03 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF Home 8x 01 06 04 FF Reset 8x 01 06 05 FF Pan tiltLimitSet Set 8x 01 06 07 00 0W 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF W 1 UpRight 0 DownLeft YYYY Pan Limit Position TBD ZZZZ Tilt Limit Position TBD Clear 8x 01 06 07 01 0W 07 0F 0F 0F 07 0F 0F 0F FF PART3 CAMERA CONTROL COMMAND Command type command return note CAM_PowerInq 8x 09 04 00 FF y0 50 02 FF On y0 50 03 FF Off Stand...

Page 21: ...CompMod eInq 8x 09 04 3E FF y0 50 02 FF On y0 50 03 FF Off CAM_ExpCompPosI nq 8x 09 04 4E FF y0 50 00 00 0p 0q FF pq ExpComp Position CAM_ApertureInq 8x 09 04 42 FF y0 50 00 00 0p 0q FF pq Aperture Gain CAM_MemoryInq 8x 09 04 3F FF y0 50 pp FF pp Memory number last operated SYS_MenuModeInq 8x 09 06 06 FF y0 50 02 FF On y0 50 03 FF Off CAM_LR_ReverseIn q 8x 09 04 61 FF y0 50 02 FF On y0 50 03 FF Of...

Page 22: ... 04 33 FF CAM_Backlight y0 07 7D 01 04 3F FF CAM_Memory y0 07 7D 01 06 01 FF Pan_tiltDrive Pan tiltMaxSpeedIn q 8x 09 06 11 FF y0 50 ww zz FF ww PanMaxSpeed zz Tilt Max Speed Pan tiltPosInq 8x 09 06 12 FF y0 50 0w 0w 0w 0w 0z 0z 0z 0z FF wwww PanPosition zzzz Tilt Position MainstreamResoluti onInq 8x 09 04 C2 00 FF y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF pqrs Column x size mnxy Line y size only support 1...

Page 23: ...5 0xFD78 60 0x0360 0 0x0000 90 0x510 45 0x0288 90 0x0510 135 0x0798 170 0x0990 VISCA PAN TILT SPEED VALUE Pan Degree Second Pan Degree Second 0 0 3 0 0 3 1 1 1 1 2 1 5 2 1 5 3 2 2 3 2 2 4 2 4 4 3 6 5 2 6 5 4 7 6 2 8 6 6 7 3 0 7 8 8 3 2 8 10 9 3 4 9 12 10 3 8 10 15 11 4 5 11 18 12 6 12 23 13 9 13 30 14 15 14 39 15 19 15 48 22 WWW EVERETIMAGING COM ...

Page 24: ...lt Speed SUM Upright 0xFF Address 0x00 0x0A Pan Speed Tilt Speed SUM DownLeft 0xFF Address 0x00 0x14 Pan Speed Tilt Speed SUM DownRight 0xFF Address 0x00 0x12 Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF Address 0x00 0x40 0x00 0x00 SUM Focus Far 0xFF Address 0x00 0x80 0x00 0x00 SUM Focus Near 0xFF Address 0x01 0x00 0x00 0x00 SUM Set Preset 0xFF Address 0x00 0...

Page 25: ...XOR Down 0Xa0 Address 0x00 0x10 Pan Speed Tilt Speed 0Xaf XOR Left 0Xa0 Address 0x00 0x04 Pan Speed Tilt Speed 0Xaf XOR Right 0Xa0 Address 0x00 0x02 Pan Speed Tilt Speed 0Xaf XOR Upleft 0Xa0 Address 0x00 0x0C Pan Speed Tilt Speed 0Xaf XOR Upright 0Xa0 Address 0x00 0x0A Pan Speed Tilt Speed 0Xaf XOR DownLeft 0Xa0 Address 0x00 0x14 Pan Speed Tilt Speed 0Xaf XOR DownRight 0Xa0 Address 0x00 0x12 Pan S...

Page 26: ... Response 0xA0 Address 0x00 0x5D Value High Byte Value Low Byte 0xAF XOR OSD MENU OSD MENU 1 Press the MENU key on the IR remote controller to enter the OSD menu as bellow 2 After enter the main menu use the navigate UP DOWN key to select the main menu Once selected the main menu will change to blue background and the right side will show all sub menu options 3 Press the navigate RIGHT key to ente...

Page 27: ...urces via COM and via IP VISCA over IP Default OVER ALL LANGUAGE Chinese English Default English EXPOSU RE EXPOSURE MODE AUTO MANUAL BRIGHT SHUTTER IRIS Default AUTO SHUTTER Shutter speed 1 8 1 10000 only valid under manual mode Default AUTO IRIS Iris setting CLOSE F1 5 only valid under manual mode Default AUTO GAIN Gain setting 0dB 28dB only valid under manual mode Default AUTO BRIGHT Bright sett...

Page 28: ...Z to reduce the video flicker Default 50HZ DZOOM Turn on off digital zoom 2x digital zoome Default OFF FOCUS Select focus mode Default AUTO QUALITY 2D NR 2D noise reduction the bigger value the less noise on image the lower resolution Default OFF 3D NR 3D noise reduction OFF AUTO 0 4 the bigger value the less motion noise on image high value will cause image smear Default AUTO SHARPNE SS Sharpness...

Page 29: ...Tilt speed Default 18 ZOOM SPD Zoom speed Default 5 MENU MIR Turn on off left menu mirror function Default NOR MAL FORMAT 3840 2160P3 0 720P50 Once selected press OK key to confirm if it is the selected video format there is no change 4K mode does not support menu switching when switch to 4K model menu will be existed automatically 3840 2160P2 5 720P29 97 1080P59 94 720P25 1080P50 1080P60 1080I59 ...

Page 30: ... 20480k SUB Stream 640 360 BIT RATE 10240 20480k RESET SYS RESET Reset communication parameter to default CAM RESET Reset camera parameter to default PT RESET Reset pan tilt parameter to default ALL RESET Reset all parameter to default INFO IR ADDR Camera IR control address USB USB firmware version CLIENT Default client end protocol VISCA ARM VER ARM firmware version FPGA VER FPGA firmware version...

Page 31: ...rd UVC interface PU_BRIGHTNESS_CONTROL 81 01 04 4d 00 00 0p 0q FF PU_CONTRAST_CONTROL 81 01 04 A2 00 00 0p 0q FF PU_SATURATION_CONTROL 81 01 04 A1 00 00 0p 0q FF PU_SHARPNESS_CONTROL 8x 01 04 42 00 00 0p 0q FF PU_GAMMA_CONTROL 8x 01 04 5B 0p FF PU_WHITE_BALANCE_TEMPERATURE_CONTROL 8x 01 04 35 0X FF PU_BACKLIGHT_COMPENSATION_CONTROL 81 01 04 33 02 03 FF PU_POWER_LINE_FREQUENCY_CONTROL 8x 01 04 AA 0...

Page 32: ...r into the settings interface as following Video Encode set image encode mode main stream and sub stream resolution bit rate frame rate bit rate control way and I frame interval etc as above image Video Transmission 31 WWW EVERETIMAGING COM ...

Page 33: ... or any other RTMP address if needed combine with RTMP adress yourstreamingkey Image Adjust to set focus exposure white balance image image quality noise reduction Focus including focus mode default focal distance digital zoom etc 32 WWW EVERETIMAGING COM ...

Page 34: ... brightness and anti flicker White Balance includes white balance mode red gain blue gain Image includes mirror flip backlight compensation Gamma WDR wide dynamic range Image Setting includes brightness sharpness contrast saturation 33 WWW EVERETIMAGING COM ...

Page 35: ...rt Defaults DHCP OFF HTTP port 80 IP address 192 168 1 188 RTSP port 554 Subnet mask 255 255 255 0 RTMP port 1935 Default gateway 192 168 1 1 Firmware upgrade for camera upgrades currently only for ISP part updates HOW TO UPDATE Click select file icon to open dialog box select to open the file Click upgrade to start the upgrade process Only use upgrade files from everet eu support website 34 WWW E...

Page 36: ...nd and select reset all to reset the camera completely Reboot Reboot ISP part of camera Account Setting is used for setting your camera account and password First Input the accountname then input password twice click ok to finish settings Please remember account and password otherwise you are not able to login 35 WWW EVERETIMAGING COM ...

Page 37: ...lay to view the real time stream Note If there is to much delay select the more option to change the buffer time VLC default buffer time is 1000ms VISCA OVER IP VISCA over IP means VISCA protocol over IP to reduce RS232 RS485 cable layout the controller must support VISCA over IP Communication port spec Control port RJ45 Gigabit LAN IP protocol IPv4 Transmit protocol UDP IP address set via web fro...

Page 38: ...rent commands camera will return different message VISCA Inquiry It means inquiry from controller to peripheral equipment when peripheral equipment receives this kind of commands it will return required message VISCA Reply It means ACK complete message reply or error reply sent from peripheral equipment to controller Command format Enclosed is the message head and message format Payload type 37 WW...

Page 39: ...Payload 1 16 is command length For example when valid data length is 16 byte Byte 2 0x00 Byte 3 0x10 Controller will save sequence number of each command when one command sent the sequence number of the command will add 1 when the sequence number becomes the max value it will change to 0 for next time The peripheral equipment will save sequence number of each command and return the sequence number...

Page 40: ...ontroller sends a command to peripheral equipment controller will wait for the return message then send the next command we can detect and confirm if the peripheral equipment received the commands from return message s lag time If controller shows it is overtime it will be marked as error transmission If controller shows it is overtime resend the commands to check peripheral s status The resent co...

Page 41: ...ence chart as specified Sequence chart when command lost Sequence chart when returned message lost Note Do not set IP address subnet mask gateway parameter in VISCA over IP command 40 WWW EVERETIMAGING COM ...