OPERATING INSTRUCTIONS 

 

Please Note: If the thermostat is set to a lower temperature than the ambient temperature, the unit will not run.  
 

THERMOSTAT CONTROL KNOB 

 

The appliance has an inbuilt thermostat which allows you to set the maximum temperature of the room. Rotate the 
Thermostat Control Knob fully anti-clockwise to set to the lowest setting. Rotate clockwise to increase the thermostat 
temperature setting.  While the appliance senses an ambient temperature lower than the set temperature, it will run. 
When the ambient temperature reaches the set temperature, the elements will shut down, and will not restart until 
the ambient temperature drops sufficiently.  
To set the temperature: 

1.

 

Turn the thermostat control knob clockwise until the maximum temperature setting is reached. 

2.

 

Once the desired ambient temperature has been reached, very slowly turn the thermostat control knob 
anti-clockwise until there is an auditable click. The thermostat has turned off and the elements will stop 
producing heat. 

3.

 

The heater elements and fan will now turn off and on automatically, maintaining the room temperature you 

have set.  To increase or reduce this temperature, the thermostat knob should be adjusted accordingly.        

 
 

FUNCTION SELECT KNOB 

 

Make sure the power supply is on. There are five settings: Off, Low power, Low power with oscillation. High power 

& High power with oscillation.  
Off: When the Setting knob is set to “Off”, the appliance will not run. 
Low Power: When the Setting knob is set to “Low Power”, only a section of the element will run (1400W) with the 
fan. 
Low Power with Oscillation: The appliance will run as per the “Low Power” setting, with the appliance body 
oscillating on its base. 

High Power: When the Setting knob is set to “High Power”, the whole element will run (2400W) with the fan. 
High Power with Oscillation: The appliance will run as per the “High Power” setting, with the appliance body 
oscillating on its base. 

 
 

SAFETY FEATURES 

 

 

1.   A thermal overload protector is built in to prevent overheating. 
2.   When an overheat temperature is reached, the heater will automatically shut off.  It can only resume operation 

when the user resets the unit (see reset instructions below). 

 
To reset your heater:  

1.

 

Unplug the heater and wait between 5-10 minutes for the unit to cool down. 

2.

 

Then, turn on the unit again and operate normally. 

 
A tilt switch is built into the unit. If tipped over the appliance will shut off. Right the appliance to restart. 
 
 

 
 
 
 
 

Summary of Contents for HCT244M

Page 1: ...HEAT LIVE RELAX OPERATION MAINTENANCE AND SAFETY INSTRUCTIONS FOR EVERDURE HEATER HCT244M...

Page 2: ...Do not insert any objects into the heater as it may cause an electric shock or fire or damage to the heater Do not block or tamper with the heater in any manner while it is in operation To prevent a p...

Page 3: ...er cord is fully unfurled 2 Plug the cord set into a 220 240V A C 50Hz electrical outlet Turn the power on at the electrical outlet Power on will be indicated by a short beep 3 The heater is now ready...

Page 4: ...ure you have set To increase or reduce this temperature the thermostat knob should be adjusted accordingly FUNCTION SELECT KNOB Make sure the power supply is on There are five settings Off Low power L...

Page 5: ...se instructions in the original packaging in a cool dry place WEEE WARNING This product should not be disposed of with household waste Please recycle where facilities exist and check with your local a...

Page 6: ...HEAT LIVE RELAX OTHER PRODUCTS AVAILABLE FROM EVERDURE Barbecues Cooking Products Gas Heaters...

Page 7: ...purchase as well as other important documents about this product for future reference Due to continual product development Everdure reserves the right to alter specifications or appearances without no...

Page 8: ...EAT LIVE RELAX A division of Shriro Australia Pty Ltd 104 Vanessa St Kingsgrove NSW 2208 In Australia 1300 766 066 In New Zealand 09 415 6000 www everdure com IM Ref HCT244M 02 2012 11 HEAT LIVE RELAX...

Reviews: