HEAT LIVE RELAX
SET BUTTON
The heater can be set to run for up to 12 hours (in 1 hour increments) and then turn off. To use the timer function,
press the SET button on the heater. The display will change from the room temperature to a flashing number (the
length in time in hours). Pressing the “+” and “-“ buttons will adjust the length of time the heater will run for. To
confirm the time, stop pressing the buttons and the display will stop flashing and return to the room temperature.
After running for the set time, the heater will turn off as normal.
To cancel the function, press the heater on/off button.
The maximum room temperature is set by pressing the SET button twice. The display shows a flashing temperature,
which is adjusted by pressing the “+” and “-“ buttons. The temperature range is 15ºC to 35º. To confirm the
maximum room temperature, stop pressing the buttons and the display will stop flashing and return to the room
temperature. The heater will run until the required temperature is reached (both the low and high indicators are off),
at which point the elements will turn off but the fan will continue to work. When the room temperature drops, the
elements will turn on again.
To exit this automatic mode, press the heater on/off button.
NOTE: The maximum room temperature set also effects the operation in manual mode; if the room temperature is
greater than the set maximum room temperature, the heater will not work.
REMOTE CONTROL
All functions that can be performed from the main unit are repeated on the remote control. Please note that:
Output high/low = “heater”
SET = “shift”
Oscillation = “scanning”
The remote control requires 1 CR2032 battery which is inserted into the bottom of the control. To use the remote
control, point at the front of the heater and push the appropriate buttons.
SAFETY FEATURES
1. There are two thermal overload protectors is built in the heater to prevent overheating. The first is resettable and
the second is non-resettable.
2. When an overheat temperature is reached, the heater will automatically shut off. It can only resume operation
when the user resets the unit (see reset instructions below).
3. If the resettable thermal overload protector fails, the non-resettable thermal overload protector will activate. If
this happens, the heat will not reset. Please contact Everdure Service.
To reset your heater:
1.
Unplug the heater and wait between 5-10 minutes for the unit to cool down.
2.
Then, turn on the unit again and operate normally.