DESIGNED TO PERFECTION
ELECTRICAL CONNECTIONS
LOCAL AUTHORITY REQUIREMENTS
Installation is only permitted by a licensed electrician, and carried out according to instructions
provided by the manufacturer. Incorrect installation might cause harm and damage, for which the
manufacturer accepts no responsibility.
ELECTRICAL INSTALLATION
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the
appliance identification plate) must be checked for correspondence to the available mains supply voltage, and
the mains electric wiring should be capable of handling the oven’s power rating (also indicated on the
identification plate). If you have any doubts, call in a qualified technician.
NOTE: For connections to the mains power supply, never use adapters, reductions or multiple power points as
these may overheat and catch fire. Do not install separate timers.
After having installed the appliance, the switched outlet must always be in an accessible position.
The electrical safety of this appliance can only be guaranteed if the cooktop is correctly and efficiently earthed,
always ensure that the earthing is efficient; if you have any doubts call in a licensed electrician to check the
system. The manufacturer declines all responsibility for damage resulting from an installation which has not
been correctly earthed.
WARNING: If any damage occurs to the power cable during or after installation, it must be replaced
immediately by a licensed electrician with a replacement cable from your Service Centre.
The cooktops are to be connected to a single phase 220-240Vac 50 Hz supply.
They are earthed via the cable.
The mains terminal block is located on the underside of the cooktop and the
terminals are accessible by removing the terminal block cover by removing the
cover screw. Connect the appliance as shown in the diagram to the right.
The appliance is designed for fixed connection to the mains. During
installation, an all pole disconnector should be included inside they supply
circuit with a contact opening of at least 3mm (rated 32A, delay functioning
type). The power supply cord must not touch against any hot surfaces and must
be placed so that its temperature does not exceed 75 °C at any point along its
length.
IMPORTANT: The appliance must NOT be connected to the mains supply by
means of a 10A or 15A plug and socket.
5