13 For Professional Technical Support call 1-844-241-5521
3.
If seat still will not locate properly, place a cardboard washer over the polished face and use a piece of 3/4 in. (19 mm) standard pipe for
pressing purposes.
:
Be sure not to scratch or mar polished surface or seal will leak.
4.
Replace slinger on end of motor shaft so that impeller sleeve will push it into position. If slinger shows signs of wear or damage, replace it.
5.
Remount seal plate on motor. Tighten bolts to 60-80 inch-lbs. (69-92 kg/cm) torque.
6.
Apply a small amount of liquid detergent to inside diameter of rotating half of seal.
7.
Slide rotating seal member, polished carbon face out, over impeller sleeve until rubber drive ring hits back of impeller.
:
Be sure not to nick or scratch polished seal face; seal will leak if face is damaged.
8.
Screw impeller onto shaft (clockwise); this will automatically locate seal in seal plate.
9.
Mount diffuser on seal plate; tighten screws to 10-14 inch-lbs. (11.2-16.1 kg/cm) torque.
10.
Assemble motor and seal plate to pump body with nuts, flat washers and lock washers. Torque nuts to 120-130 in-lbs. (138-150 kg/cm).
11.
Prime pump according to instructions in Priming Pump.
:
Risk of electric shock.
Can shock, burn or kill.
Disconnect power before working on pump or motor.
Read and understand safety and operating instructions in this manual before doing any work on pump!
Only qualified personnel should electrically test pump motor!
Problem
Possible Cause
Corrective Action
Pump will not prime.
The suction piping leaks or there is no
prime.
Pump must be primed; make sure that pump volute and trap are
full of water. See Priming Pump.
Make sure there are no leaks in suction piping.
Make sure suction pipe inlet is well below the water level to
prevent pump from sucking air.
If suction trap gasket is defective, replace it.
The water level is below the suction pipe
inlet.
Make sure pump is not trying to lift water more than 10 ft. (3 m).
Make sure suction pipe is at least 1-1/2 in. (38 mm) in diameter.
Pump operates but pumps little
or no water.
There is a clogged pipe, trap, impeller, or
there is a worn impeller.
Make sure suction trap is not clogged; if it is, clean trap and
strainer.
Make sure impeller is not clogged (follow instructions in
Removing Old Seal; check impeller for clogging; follow
instructions in Installing New Seal for reassembly).
Impeller and diffuser may be worn. If so, order replacement
parts by calling customer service.