9….. Timer Setting (Up) 

Increase the number on the timer setting   

10…..Function Button 

Press to switch between Dispense and Reverse timer setting

 

11…..Timer Setting (Down) 

Decrease the number on the timer setting 

12…..Reverse Time Display 

Display currently reverse time setting (0.01sec – 99.99sec) 

13…..Dispense Time Display 

Display currently dispense time setting (0.01sec – 99.99sec) 

14…..Finger Switch Port 

Connect with finger switch, insert to adapt 

 

4. Operation

: 

a. 

Please insert and fasten the Teflon Tube inside the Rotary Pump correctly according to the figure 1. 

b. 

Use Fast Switch to load the adhesive inside the Teflon Tube till the tip. 

c. 

Press down the Training Button to active trainning mode to set the dispense time for each time. 

d. 

If Adhesive is dripping off the tip between each dispensing, you can set the reverse time longer. 

e. 

Please make sure the Rotary Pump rotating speed and direciton is correct. 

f. 

Turn off the training mode, then the adhesive will dispense and reverse according the the timer setting. 

g. 

Use Fast Switch to unload the adhesive inside the Teflon Tube back to the adhesive bottle to save usage. 

 

5.  Three main reasons that control the dispensing volume

 

 

Needle type and size

 

 

   

Teflon Tube Size

 

 

 

Rotary Pump Speed

 

 

6.  Maintenance and Precaution

 

The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following 

recommendations should be followed

 

a. 

Please make sure the Teflon Tube is under good condition. If it is clogged or deformed, please replace it. 

b. 

Make sure the Teflon Tube is fasten inside the Rotary Pump correctly, else it will clogged inside the Pump and 

cause serious damage. 

c. 

Teflon Tube will deform after long period of usage and causes inconsistent dispensing. Untie the Teflon Tube 

inside the Rotary Pump and relocate it with good condition section. 

d. 

Use only Amyl Alcohol to clean outside surface of the main housing. 

e. 

Please take off the Teflon Tube with needle after use and rinse through solvent.

   

 

Summary of Contents for ES2088

Page 1: ...itch 2 Hardware Setup a Connect the Power Cord on the back of the system and switch the power on Please make sure all the display and light indicator are working properly 110V 240V full voltage b Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system c Place the teflon tube inside the rotary pump d Insert the front end of the teflon tube inside the dispensing ...

Page 2: ...nning mode 3 Dispense Button Press this button to activate the dispensing process 4 Fast Switch Switch left to rotate Rotary Pump counter clockwise continuously right side will rotate clockwise 5 Rotate Speed Button Set the Rotary Pump rotating speed 0 50 6 Rotate Speed Display Display currently rotary speed 7 Counter Clockwise Button Press down to active the Rotary Pump rotating counter clockwise...

Page 3: ... make sure the Rotary Pump rotating speed and direciton is correct f Turn off the training mode then the adhesive will dispense and reverse according the the timer setting g Use Fast Switch to unload the adhesive inside the Teflon Tube back to the adhesive bottle to save usage 5 Three main reasons that control the dispensing volume Needle type and size Teflon Tube Size Rotary Pump Speed 6 Maintena...

Page 4: ...e vacuum setting and de bubble the adhesive before filling replace with different type of needle replace needle replace Teflon Tube 8 Limited warranty Ever Sharp warrants this product to the original purchaser for a period of one year from date of purchase to be free from material and workmanship defects but not normal wear and tear abuse and faulty installation Defective product or subassembly an...

Reviews: