9….. Timer Setting (Up)
Increase the number on the timer setting
10…..Function Button
Press to switch between Dispense and Reverse timer setting
11…..Timer Setting (Down)
Decrease the number on the timer setting
12…..Reverse Time Display
Display currently reverse time setting (0.01sec – 99.99sec)
13…..Dispense Time Display
Display currently dispense time setting (0.01sec – 99.99sec)
14…..Finger Switch Port
Connect with finger switch, insert to adapt
4. Operation
:
a.
Please insert and fasten the Teflon Tube inside the Rotary Pump correctly according to the figure 1.
b.
Use Fast Switch to load the adhesive inside the Teflon Tube till the tip.
c.
Press down the Training Button to active trainning mode to set the dispense time for each time.
d.
If Adhesive is dripping off the tip between each dispensing, you can set the reverse time longer.
e.
Please make sure the Rotary Pump rotating speed and direciton is correct.
f.
Turn off the training mode, then the adhesive will dispense and reverse according the the timer setting.
g.
Use Fast Switch to unload the adhesive inside the Teflon Tube back to the adhesive bottle to save usage.
5. Three main reasons that control the dispensing volume
:
Needle type and size
Teflon Tube Size
Rotary Pump Speed
6. Maintenance and Precaution
:
The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following
recommendations should be followed
:
a.
Please make sure the Teflon Tube is under good condition. If it is clogged or deformed, please replace it.
b.
Make sure the Teflon Tube is fasten inside the Rotary Pump correctly, else it will clogged inside the Pump and
cause serious damage.
c.
Teflon Tube will deform after long period of usage and causes inconsistent dispensing. Untie the Teflon Tube
inside the Rotary Pump and relocate it with good condition section.
d.
Use only Amyl Alcohol to clean outside surface of the main housing.
e.
Please take off the Teflon Tube with needle after use and rinse through solvent.