background image

11 

 

www.event-lighting.com.au 

15  18 

13 

15 

Prism&           
Prism Rot 

Prism 

 

 

 

 

Position 1 (Open) 

Prism Rot Forward Spin 

 

 

 

 

Slow to fastest 

127 

Prism Rot Stop 

128 

131 

Prism Rot Reverse Spin 

 

 

 

 

Slow to fastest 

131 

255 

16  19 

14 

16  Focus 

Continuous 

 

 

 

 

Focus In to Focus Out 

255 

17  20 

 

 

 

  Frost 

Continuous 

 

 

 

 

No Frost 

127 

Frost 0->100% 

128 

255 

18  21 

15 

17  Control 

Normal 

Reset All 

15 

Pan & Tilt Reset 

16 

23 

Color Reset 

24 

31 

Gobo Reset 

32 

39 

TBD 

40 

47 

Other Reset 

48 

55 

Display Off 

56 

63 

Display On 

64 

71 

TBD 

72 

79 

TBD 

80 

87 

Hibernation 

88 

95 

TBD 

96 

255 

 

The  device  is  controlled  by  universal  DMX  512  protocol,  DMX  address  is  the  start  channel  used  to  receive 

instructions from the external controller. For independent control, each fixture must be assigned its unique address 

control channels. For example, this device has four channel modes: 21/24/14/16, if we set the mode at standard 21 

channels  mode,  and  there are several  models need  to be  independently controlled,  we  just simply  address first 

fixture at 1, and second fixture at 22, third one at 43, etc.   

 

If the devices have the same address, they will behave synchronically.   

 

Display is flashing when no DMX signal is received. 

 

More functions 

RDM. RDM stands for “Remote Device Management”, with this function, users can realize remote control of  the 

device, such as remotely changing DMX address, reverse pan/tilt setting, check a lot of useful information such as 

temperature,  power  consumption,  fan  speed.  Etc.  Every  single  device  has  a  unique  RDM  code  programmed  at 

manufacture to distinguish from each other. It is not recommended for users to change this code.   

 

Software upgrade function via DMX cable. If there is any new firmware for this device, it can be upgraded simply via 

Summary of Contents for M1B50W

Page 1: ... the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au V1 0 ...

Page 2: ...ircuit ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 8A DO NOT exceed this Fuse Replacem...

Page 3: ... 2 Head 3 Arm 4 Base 5 Display 6 Foot stand 7 Operation button 8 Handle 9 Wireless indicator 10 Mic 11 Left button 12 Battery indicator 13 Up button 14 Down button 15 Enter button 16 Right button 17 Powercon in 18 Powercon out 19 Fuse 20 Power switch 21 5 pin DMX in 22 5 pin DMX out ...

Page 4: ...4 www event lighting com au Gobo wheel Static gobo wheel ...

Page 5: ...ting com au Position 1 Position 10 Position 2 Position 11 Position 3 Position 12 Position 4 Position 13 Position 5 Position 14 Position 6 Position 15 Position 7 Position 16 Position 8 Position 17 Position 9 Position 18 ...

Page 6: ...epends on fixture Fan speed Sensors Channel Value PAN Display value of channel Error Message Pan Tilt Error channels Fixture Model xxxxxxxxxxxx Display model brand and model Software Ver 1U01 V1 0 00 Version of each IC Set Reset All Pan Tilt Colors Gobos Others Reset all Reset Pan Tilt Reset Colors Reset Gobos Reset Others Movment Pan Reverse Tilt Reverse Pan Degree Encoders Pan Tilt Mode ON OFF O...

Page 7: ...X Send Out Reset Connect Reload Default Basic Reload Program Reload Password Private Reload All Reload ON OFF ON OFF XXX ON OFF ON OFF Basic Reload Program Reload Password 050 Private Reload All Reload Program Play DMX Receive Slave Receive Sequence Music Slave Receive 1 2 3 Master Alone Master Alone DMX Receive Choose slave position Run Sequence Music mode Select Chase Chase Part 1 Chase Part 2 C...

Page 8: ... Normal Shutter Functions Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 Pulse effect Forward Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 Pulse effect Reverse Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 Random Strobe Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 4 6 Shutter Shutter closed 0 31 No function shutter open 32 63 Strobe effect slow to fast 64 9...

Page 9: ... 0 Green up Blue full 5 46 Red 0 Green full Blue down 47 88 Red up Green full Blue 0 89 130 Red full Green down Blue 0 131 172 Red full Green 0 Blue up 173 214 Red down Green 0 Blue full 215 255 9 12 8 10 Virtual Color2 Only On Color Bounce Color Bounce Black 0 0 Red 1 1 Green 2 2 Blue 3 3 Red full Green full Blue full 4 4 Red 0 Green up Blue full 5 46 Red 0 Green full Blue down 47 88 Red up Green...

Page 10: ...11 140 153 Position 12 154 167 Position 13 168 181 Position 14 182 195 Position 15 196 209 Position 16 210 223 Position 17 224 237 Position 18 238 255 Forward Wheel Spin Stop to fastest 0 255 Reverse Wheel Spin Stop to fastest 0 255 Continuous Positioning from 0 360 degrees 0 255 12 14 Gobo Indexed Position 1 Open 0 1 Position 2 Position 18 2 35 Indexed With Blackout Position 1 Open 36 37 Position...

Page 11: ...dress control channels For example this device has four channel modes 21 24 14 16 if we set the mode at standard 21 channels mode and there are several models need to be independently controlled we just simply address first fixture at 1 and second fixture at 22 third one at 43 etc If the devices have the same address they will behave synchronically Display is flashing when no DMX signal is receive...

Page 12: ...splay will flip automatically this function is useful to read menu conveniently when device is hanged Technical Specifications Power Input Voltage 100 240V AC 50 60 Hz Power Consumption 106W Connection Neutrik PowerCON In Out Photometric Light Source 50W RGB LED Module Beam Angle 2 Output 1335 lumen 161000 lux on 3M PWM 1200Hz LED Lifespan 50 000 hours Effects Dimming 0 100 Strobe 0 5 26 Hz Focus ...

Page 13: ...or Thermostat Controlled Variable Speed Fan IP rating IP20 Dimension 299 x 437 x 398 mm Net Weight 10kg Rigging 2pcs Omega Brackets with 1 4 turn Quick Locks MISC Road case MCASE4SS WARRANTY Please refer to your local dealer or please contact Event Lighting Pty Ltd Website www event lighting com au ...

Reviews: