11
www.event-lighting.com.au
15 18
13
15
Prism&
Prism Rot
Prism
Position 1 (Open)
0
3
Prism Rot Forward Spin
Slow to fastest
4
127
Prism Rot Stop
128
131
Prism Rot Reverse Spin
Slow to fastest
131
255
16 19
14
16 Focus
Continuous
Focus In to Focus Out
0
255
17 20
Frost
Continuous
No Frost
0
127
Frost 0->100%
128
255
18 21
15
17 Control
Normal
0
7
Reset All
8
15
Pan & Tilt Reset
16
23
Color Reset
24
31
Gobo Reset
32
39
TBD
40
47
Other Reset
48
55
Display Off
56
63
Display On
64
71
TBD
72
79
TBD
80
87
Hibernation
88
95
TBD
96
255
-
The device is controlled by universal DMX 512 protocol, DMX address is the start channel used to receive
instructions from the external controller. For independent control, each fixture must be assigned its unique address
control channels. For example, this device has four channel modes: 21/24/14/16, if we set the mode at standard 21
channels mode, and there are several models need to be independently controlled, we just simply address first
fixture at 1, and second fixture at 22, third one at 43, etc.
-
If the devices have the same address, they will behave synchronically.
-
Display is flashing when no DMX signal is received.
More functions
-
RDM. RDM stands for “Remote Device Management”, with this function, users can realize remote control of the
device, such as remotely changing DMX address, reverse pan/tilt setting, check a lot of useful information such as
temperature, power consumption, fan speed. Etc. Every single device has a unique RDM code programmed at
manufacture to distinguish from each other. It is not recommended for users to change this code.
-
Software upgrade function via DMX cable. If there is any new firmware for this device, it can be upgraded simply via