WARNING 

• Do not open this device, there is no user-serviceable parts inside. Risk of electric shock. 

• Do not look at the light source when the device is on. 

• 

CAUTION

: This unit's housing may be hot during and after operation. 

• Install this device in a location with adequate ventilation, at least 20 inch (50 cm) from adjacent 

surfaces. 

• Do not leave any flammable material within 50 cm of this unit while operating or connected to power. 

• Use a safety chain when mounting this device overhead. 

• Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity 

may affect it. 

• Do not operate this device if the housing, lenses, or cables appear damaged. 

• Do not connect this device to a dimmer or rheostat. 

• ONLY connect this device to a grounded and protected circuit. 

• ONLY use the hanging bracket to carry this device. 

• In case of a serious operating problem, stop using immediately. 

• The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher 

temperatures. 

Power Input & Power Linking 

This device has an auto-switching power supply work with input voltage range of 100~240 VAC, 

50/60 Hz. 

Link up to the maximum 8A. DO NOT exceed this. 

Fuse Replacement 

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. 

Before replacing the fuse, unplug mains lead. 

Procedure: 

Step 1: Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing 

(anticlockwise). 

Step 2: Remove the old fuse from the fuse holder.   

Step 3: Install the new fuse in the fuse holder. 

Step 4: Replace the fuse holder in the housing and fix it. 

Summary of Contents for Lite LM7X30

Page 1: ...rves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au V1 0 ...

Page 2: ...not connect this device to a dimmer or rheostat ONLY connect this device to a grounded and protected circuit ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with ...

Page 3: ...hting com au Product Installation This device can be mounted in many orientations provided each individual device is secured by the use of correct mounting bracket Use a safety chain when mounting this device overhead ...

Page 4: ...1m 3m 5m Ø0 11 Ø0 31 Ø0 52 R 22 800 3 280 1 310 G 25 300 3 940 1 150 B 39 900 6 050 2 280 W 43 000 6 700 2 590 FULL 115 000 19 130 7 230 Lux Chart 60 1m 3m 5m Ø1 16 Ø3 46 Ø5 77 R 2 060 320 136 G 2 690 360 150 B 4 260 590 210 W 4 670 620 230 FULL 13 200 1 760 630 ...

Page 5: ...set to Default Setting Signal Set DMX Wireless DMX Wireless TX Wired DMX Wireless DMX Receiver Wireless DMX Transceiver Reverse Pan On Off Reverse Pan Reverse Tilt On Off Reverse Tilt Select Pan 630 540 360 Select Pan Default 540 Select Tilt 270 180 90 Select Tilt Default 270 Mic Sens 0 99 Microphone Sensitivity Setting Hold on no DMX On Off Hold or no hold when no Signal ON 复位状态 Limit Mode OFF Ce...

Page 6: ... slow to fast 224 255 Shutter open 3 3 Pan 0 255 PAN Movement 4 Pan Fine 0 255 Fine control of Pan movement 5 4 Tilt 0 255 Tilt Movement 6 Tilt Fine 0 255 Fine control of Tilt movement 7 5 Zoom 0 255 In near to out far 8 6 Speed pan tilt 0 225 Pan tilt speed fast to slow 226 235 Blackout during pan tilt functions 236 255 TBD 9 7 Red 0 255 Red 0 100 10 8 Green 0 255 Green 0 100 11 9 Blue 0 255 Blue...

Page 7: ... TBD 16 45 Below 3200K 46 75 3200K 3500K 76 105 3500K 5000K 106 135 5000K 5500K 136 165 5500K 6000K 166 195 6000K 6500K 196 225 6500K 7000K 226 255 7000K 8000K 16 14 Visual Tungsten Lamp 0 15 TBD 16 255 Tungsten lamp effect is gradually enhanced 17 15 Special function 0 19 TBD 20 39 TBD 40 59 TBD 60 79 TBD 80 84 Reset all 85 94 Reset scan 95 99 Reset zoom 100 109 Internal program 1 110 119 Interna...

Page 8: ...iversal DMX 512 protocol DMX address is the start channel used to receive instructions from the external controller For independent control each fixture must be assigned its unique address control channels For example this device has two channel modes 15 17 if we set the mode at standard 17 channels mode and there are several models need to be independently controlled we just simply address first ...

Page 9: ... period of disconnecting DMX signal to save power and will wake immediately when the DMX signal is sent or received again Technical Specifications Power Input Voltage 90 260V AC 50 60 Hz Power Consumption 240W Connection PowerCon in Fuse F4A 250V Photometric Light Source 7pcs 30W RGBW LEDs Beam Angle 6 60 Output 19 130lux 3m 6 PWM 1 000Hz LED Lifespan 50 000hours Effects Dimming 0 100 Strobe 1 4 2...

Page 10: ...ch TFT LCD display control panel Housing Materials Metal flame retardant ABS Finishing Matte black IP rating IP20 Cooling Fan Net Weight 6kg Rigging 1pc omega brackets with 1 4 turn quick locks WARRANTY Please refer to your local dealer or contact Event Lighting Pty Ltd ...

Reviews: