AIRCRAFT OPERATING INSTRUCTIONS
Doc. No. HARMAOIUS
June 01, 2011
3-7
Section 3
Emergency
Procedures
10. Emergency landing
carry out according to
paragraph 3.8.1
11. Airplane
leave
12. Manual extinguisher (if available)
use as needed
3.6 Fire in the cockpit
(if manual extinguisher available aboard)
1. Fire source
identify
2. Master switch in case that the source
of fire is electrical equipment.
OFF
3. Manual extinguisher
use
4. After fire extinguishing
aerate the cockpit
open eye-ball vents
5. Carry out safety landing according to 3.8.2
WARNING
NEVER AGAIN SWITCH THE DEFECTIVE SYSTEM.
NOTE
If a defective electrical system circuit was
detected as the fire source, then switch off
appropriate circuit breaker and switch over
Master Switch to ON position.
3.7 Gliding flight
NOTE
Gliding flight can be used for example in
case of engine failure.
Wing flaps position
Retracted (0
°)
Take-off (15
°)
Airspeed
59 KIAS
(68 mph IAS)
55 KIAS
(63 mph IAS)