EVCO S.p.A. | EV3H94 | Instruction sheet ver. 1.0 | Code 1043H94E104 | Page 1 of 5 | PT 05/21 

EV3H94

 

Controller for DHW heat pump heaters

 

 

 

 

 

EN 

ENGLISH 

power supply 115... 230 VAC 

DHW tank upper and lower probe, evaporator probe (PTC/NTC/Pt 1000) 

photovoltaic, HP and multi-purpose digital input (see i0) 

compressor relay 16 A res. @ 250 VAC 

alarm buzzer  

TTL MODBUS slave port for EVconnect app, EPoCA remote monitoring system or for 

BMS. 

 

1

 

MEASUREMENTS AND INSTALLATION

 

Measurements in mm (inches). To be fitted to a panel, snap-in brackets provided. 

 

 

 

INSTALLATION PRECAUTIONS

 

the thickness of the panel must be between 0.8 and 2.0 mm (1/32 and 1/16 in);

 

ensure  that  the  working  conditions  are  within  the  limits  stated  in  the  TECHNICAL 

SPECIFICATIONS section;

 

do not install the device close to heat sources, equipment with a strong magnetic field, 

in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations 

or shocks;

 

in compliance with safety regulations, the device must be installed properly to ensure 

adequate  protection  from  contact  with  electrical  parts.  All  protective  parts  must  be 

fixed in such a way as to need the aid of a tool to remove them.

 

 

2

 

ELECTRICAL CONNECTION

 

 

 

N.B. 

-  use cables of an adequate section for the current running through them. 

-  to reduce any electromagnetic interference locate the power cables as far away as 

possible from the signal cables. 

 

 

 

PRECAUTIONS FOR ELECTRICAL CONNECTION

 

if using an electrical or pneumatic screwdriver, adjust the tightening torque;

 

if the device is moved from a cold to a warm place, humidity may cause condensation 

to form inside. Wait for about an hour before switching on the power;

 

make  sure  that  the  supply  voltage, electrical  frequency  and  power are  within  the  set 

limits. See the section TECHNICAL SPECIFICATIONS;

 

disconnect the power supply before carrying out any type of maintenance;

 

do not use the device as a safety device;

 

for repairs and for further information, contact the EVCO sales network.

 

 

3

 

FIRST-TIME USE

 

1. 

Carry out the installation following the instructions given in the section MEASUREMENTS 

AND INSTALLATION

2. 

Power  up  the  device  as  set  out  in  the  section  ELECTRICAL  CONNECTION:  an  internal 

test will start up. 

 

The test normally takes a few seconds; when it is finished the display will switch off. 

3. 

Configure the device as shown in the section Setting configuration parameters

 

Recommended configuration parameters for first-time use: 

PAR.

 

DEF.

 

PARAMETER

 

MIN... MAX.

 

SP1

 

55.0

 

setpoint in economy mode

 

r3... r4

 

SP2

 

65.0

 

setpoint in comfort mode

 

r1... r2

 

P0

 

 

 

type of probe 

 

0  = PTC 

1  = NTC 

2  = Pt 1000 

P2 

temperature measurement unit 

0  = °C 

1  = °F 

P3 

 

 

 

 

 

 

enabled probes 

 

 

 

0  = DHW tank upper probe + high 

  pressure input 

1  = DHW  tank  upper  and  lower 

probe 

d1 

 

 

 

 

type of defrost 

 

 

0  = electric 

1  = hot gas 

2  = compressor stopped 

3  = hot gas balancing the pressure 

 

 

Then  check  that  the  remaining  settings  are  appropriate;  see  the  section  CONFIGURA-

TION PARAMETERS

4. 

Disconnect the device from the mains. 

5. 

Make the electrical connection as shown in the section ELECTRICAL CONNECTION with-

out powering up the device. 

6. 

For  the  connection  in  an  RS-485  network  connect  the  interface  EVIF22TSX  or 

EVIF23TSX, to activate real time functions connect the module EVIF23TSX, to use the 

device with the EPoCA remote monitoring system, connect the EVIF25TWX module, to 

use the device with the APP EVconnect connect the interface EVIF25TBX; see the rele-

vant instruction sheets. If  EVIF22TSX  or  EVIF23TSX  is  used,  set  parameter  bLE 

to 0.  

7. 

Power up the device. 

 

USER INTERFACE AND MAIN FUNCTIONS 

 

 

 

4.1 

Switching the device on/off 

1. 

 

Touch the ON/STAND-BY key for 4 s. 

If the device is switched on, the display will show the P5 value ("DHW tank upper temperature" 

default); if the display shows an alarm code, see the section ALARMS. 

LED 

ON 

OFF 

FLASHING 

 

compressor 

switched 

on 

compressor 

switched 

off 

- compressor protection active 

  -  setpoint being set 

 

defrost active 

 

 

 

 

fans switched on 

 

fans switched off 

 

 

HACCP 

alarm active 

 

 

 

 

compressor 

mainte-

nance request 

 

operation  with  EVconnect  APP  ac-

tive  

°C/°F 

temperature display 

 

 

 

AUX 

heaters switched on 

 

heaters switched off 

 

 

 

device switched off 

 

device switched on 

 

 

 

When 30s have elapsed without the keys being pressed, the display will show the "Loc" label 

and the keypad will lock automatically. 

H

ig

h

 p

re

ssu

re

 s

w

it

ch

 

electric 

Summary of Contents for EV3H94

Page 1: ... given in the section MEASUREMENTS AND INSTALLATION 2 Power up the device as set out in the section ELECTRICAL CONNECTION an internal test will start up The test normally takes a few seconds when it is finished the display will switch off 3 Configure the device as shown in the section Setting configuration parameters Recommended configuration parameters for first time use PAR DEF PARAMETER MIN MAX...

Page 2: ...gionella and overboost functions are not active compressor switched on if d1 1 defrost relay active if d1 1 or 2 fans switched on if d1 2 heaters switched on to prevent too high temperature drop in the storage tank 5 6 Photovoltaic system It activates with photovoltaic input active operation as in comfort mode except for SP2 setpoint which becomes SP6 setpoint 5 7 Green It activates with multi pur...

Page 3: ... 1 SP1 55 0 setpoint in economy mode r3 r4 2 SP2 65 0 setpoint in comfort mode r1 r2 3 SP3 45 0 overboost activation threshold 10 C F r2 4 SP5 55 0 heat pump switch off threshold r1 SP2 5 SP6 75 0 photovoltaic system setpoint 40 100 C F 6 SP7 5 0 setpoint in antifreeze mode 0 40 C F 7 SP8 40 0 setpoint in green mode 0 100 C F 8 SP9 7 0 cold evaporator alarm threshold 25 25 C F 9 SPA 25 evaporator ...

Page 4: ... min 00 00 disabled N PAR DEF SAFETIES MIN MAX 81 PA1 426 level 1 password 99 999 82 PA2 824 level 2 password 99 999 N PAR DEF DATA LOGGING EVLINK MIN MAX 83 bLE 1 enable Bluetooth 0 no 1 sì 1 reserved 84 rE0 15 data logger sampling inter val 0 240 min 85 rE1 1 recorded temperature 0 nessuna 1 DHW tank upper 2 DHW tank lower 3 evaporator 4 DHW tank upper and lower 5 tutte N PAR DEF MODBUS MIN MAX ...

Page 5: ...rm buzzer Built in Communication ports 1 TTL MODBUS slave port for EVconnect app EPoCA remote monitoring system or for BMS N B The device must be disposed of according to local regulations governing the collection of electrical and electronic equipment This document and the solutions contained therein are the intellectual property of EVCO and thus pro tected by the Italian Intellectual Property Ri...