Evco EV3143 Manual Download Page 3

EVCO S.p.A. | EV3143 | Instruction sheet ver. 1.0 | Code 1043143E103 | Page 3 of 3 | PT 22/19 

97 

 

F1S 

 

 

seconds  beater  off  during  batch 

freezing heating 

0... 59 s 

 

 

 

NO.  PAR. 

DEF.  BATCH FREEZING COOKING 

MIN... MAX. 

98 

 

 

SPC 

 

 

30.0 

 

 

plate setpoint during batch freez-

ing  cooking  and  plate  setpoint 

during batch freezing cooking 

r23... r24 

 

 

99 

 

 

SU2 

 

 

30.0 

 

 

tank  setpoint  at  end  of  batch 

freezing heating and tank setpoint 

during batch freezing cooking 

r25... r26 

 

 

100 

 

r2H 

 

2.0 

 

tank  differential  setpoint  during 

batch freezing cooking 

1... 25 °C/°F 

 

101 

 

C2H 

 

 

duration in hours of batch freezing 

cooking 

0... 23 h 

 

102 

 

C2n 

 

 

duration  in  minutes  of  batch 

freezing cooking 

0... 59 min 

 

103 

 

C2S 

 

 

duration  in  seconds  of  batch 

freezing cooking 

0... 59 s 

 

104 

 

n2H 

 

 

hours  beater  on  during  batch 

freezing cooking 

0... 23 h 

 

105 

 

n2n 

 

 

minutes  beater  on  during  batch 

freezing cooking 

0... 59 min 

 

106 

 

n2S 

 

 

seconds  beater  on  during  batch 

freezing cooking 

0... 59 s 

 

107 

 

F2H 

 

 

hours  beater  off  during  batch 

freezing cooking 

0... 23 h 

 

108 

 

F2n 

 

 

minutes  beater  off  during  batch 

freezing cooking 

0... 59 min 

 

109 

 

F2S 

 

 

seconds  beater  off  during  batch 

freezing cooking 

0... 59 s 

 

 

 

NO.  PAR. 

DEF.  BATCH FREEZING COOLING 

MIN... MAX. 

110 

 

 

 

SU3 

 

 

 

30.0 

 

 

 

tank  setpoint  at  end  of  batch 

freezing cooling and tank setpoint 

during  batch  freezing  conserva-

tion 

r27... r28 

 

 

 

111 

 

SA3 

 

10.0 

 

tank setpoint for beater on at end 

of batch freezing cooking 

0... 25 °C/°F 

 

112 

 

n3H 

 

 

hours  beater  on  during  batch 

freezing cooling 

0... 23 h 

 

113 

 

n3n 

 

 

minutes  beater  on  during  batch 

freezing cooling 

0... 59 min 

 

114 

 

n3S 

 

 

seconds  beater  on  during  batch 

freezing cooling 

0... 59 s 

 

115 

 

F3H 

 

 

hours  beater  off  during  batch 

freezing cooling 

0... 23 h 

 

116 

 

F3n 

 

 

minutes  beater  off  during  batch 

freezing cooling 

0... 59 min 

 

117 

 

F3S 

 

 

seconds  beater  off  during  batch 

freezing cooling 

0... 59 s 

 

 

 

NO. 

 

PAR. 

 

DEF. 

 

BATCH  FREEZING  CONSERVA-

TION 

MIN... MAX. 

 

118 

 

r4H 

 

2.0 

 

tank  differential  setpoint  during 

batch freezing conservation 

1... 25 °C/°F 

 

119 

 

n4H 

 

 

hours  beater  on  during  batch 

freezing conservation 

0... 23 h 

 

120 

 

n4n 

 

 

minutes  beater  on  during  batch 

freezing conservation 

0... 59 min 

 

121 

 

n4S 

 

 

seconds  beater  on  during  batch 

freezing conservation 

0... 59 s 

 

122 

 

F4H 

 

 

hours  beater  off  during  batch 

freezing conservation 

0... 23 h 

 

123 

 

F4n 

 

 

minutes  beater  off  during  batch 

freezing conservation 

0... 59 min 

 

124 

 

F4S 

 

 

seconds  beater  off  during  batch 

freezing conservation 

0... 59 s 

 

 

125 

 

 

 

 

F4C 

 

 

 

 

 

 

 

 

beater  mode  during  batch  freez-

ing conservation 

 

 

 

0  = independent on the com-

pressor 

1  = on if compressor on, ac-

cording to n4... and F4... 

if compressor off 

 

NO.  PAR. 

DEF.  SECURITY 

MIN... MAX. 

126  H4E 

timeout for locking the keypad 

0... 240 s 

127  POF 

enable ON/STAND-BY key 

0  = no 

1  = yes 

128  PAS 

-19 

password 

-99... 999 

129  PA1 

- - - 

unused 

130  PA2 

- - - 

unused 

 

NO.  PAR. 

DEF.  UNUSED 

MIN... MAX. 

131 

Hr0 

- - - 

unused 

 

NO.  PAR. 

DEF.  UNUSED 

MIN... MAX. 

132 

rE0 

- - - 

unused 

133 

rE1 

- - - 

unused 

 

NO.  PAR. 

DEF.  MODBUS 

MIN... MAX. 

134 

LA 

247 

MODBUS address 

1... 247 

135 

 

 

 

Lb 

 

 

 

 

 

 

MODBUS baud rate 

 

 

 

0  = 2,400 baud 

1  = 4,800 baud 

2  = 9,600 baud 

3  = 19,200 baud 

136 

bLE 

- - - 

unused 

 

NO.  PAR. 

DEF.  SECURITY 

MIN... MAX. 

137 

 

bu1 

 

 

duration  of  buzzer  activation 

when setpoint reached 

0... 240 s 

 

138 

 

 

 

Pbu 

 

 

 

 

 

 

enable buzzer 

 

 

 

0  = disabled 

1  = keys only 

2  = alarms only 

3  = keys and alarms 

 

ALARMS 

 

CODE  DE8CRIPTION 

RESET 

TO CORRECT 

Pr1 

probe 1 alarm 

automatic 

-  check P0 

Pr2 

probe 2 alarm 

automatic 

-   check integrity of the probe 

 

 

 

-   check electrical connection 

rtc 

unused 

unused 

unused 

AL1 

 

low 

temperature 

alarm 

probe 1 

automatic 

 

check A1 and A2 

 

AH1 

 

high 

temperature 

alarm 

probe 1 

automatic 

 

check A4 and A5 

 

AL2 

 

low 

temperature 

alarm 

probe 2 

automatic 

 

check A11 and A12 

 

AH2 

 

high 

temperature 

alarm 

probe 2 

automatic 

 

check A14 and A15 

 

id 

door open alarm 

automatic 

check i5 and i6 

PF 

 

power failure alarm 

 

manual 

 

-   touch a key 

-   check electrical connection 

COH 

high condensation signal 

automatic 

check C13 

CSd 

 

high condensation alarm 

 

manual 

 

-  switch the device off and on 

-  check C14 

iA 

multi-purpose input alarm 

automatic 

check i5 and i6 

it 

 

thermal switch alarm 

 

automatic 

 

-  switch the device off and on 

-  check i5 and i6 

 

10 

TECHNICAL SPECIFICATIONS 

 

Purpose of the control device: 

function controller. 

Construction of the control device: 

built-in electronic device. 

Housing: 

black, self-extinguishing. 

Category of heat and fire resistance: 

D. 

Measurements: 

 

 

 

75.0 x  33.0  x 59.0  mm  (2  15/16  x  1 5/16 x  

2 5/16 in) with fixed screw terminal blocks 

75.0 x 33.0 x 81.5 mm (2 15/16 x 1 5/16 x 

3 3/16 in) with plug-in screw terminal blocks 

Mounting methods for the control device: 

 

to be fitted to a panel, snap-in brackets pro-

vided 

Degree of protection provided by the casing: 

IP65 (front). 

Connection method: 

 

 

 

fixed screw terminal blocks for 

wires up to 2.5 mm² 

 

plug-in screw terminal blocks 

for  wires  up  to  2.5  mm²  (on 

request) 

Micro-MaTch connector 

 

 

Maximum permitted length for connection cables: 

power supply: 10 m (32.8 ft) 

analogue inputs: 10 m (32.8 ft) 

digital inputs: 10 m (32.8 ft) 

digital outputs: 10 m (32.8 ft). 

Operating temperature: 

from 0 to 55 °C (from 32 to 131 °F). 

Storage temperature: 

from -25 to 70 °C (from -13 to 158 °F). 

Operating humidity: 

 

relative humidity without condensate from 10 

to 90%. 

Pollution status of the control device: 

2. 

Compliance: 

 

 

 

RoHS 2011/65/EC 

 

WEEE 2012/19/EU 

 

REACH 

(EC) 

Regulation  

no. 1907/2006 

EMC 2014/30/EU 

LVD 2014/35/EU. 

Power supply: 

 

 

 

230 VAC (+10% -15%), 50/60 Hz (±3 Hz), max. 2 VA insulated in EV3143N7 

115 VAC (+10% -15%), 50/60 Hz (±3 Hz), max. 2 VA insulated in EV3143N5. 

Earthing methods for the control device: 

none. 

Rated impulse-withstand voltage: 

4 KV. 

Over-voltage category: 

III. 

Software class and structure: 

A. 

Analogue inputs: 

 

2 for PTC or NTC probes (probe 1 and probe 

2). 

PTC probes: 

Type of sensor: 

KTY 81-121 (990 

 @ 25 °C, 77 °F) 

 

Measurement field: 

from -50 to 150 °C (from -58 to 302 °F) 

 

Resolution: 

0.1 °C (1 °F). 

NTC probes: 

Type of sensor: 

ß3435 (10 K

 @ 25 °C, 77 °F) 

 

Measurement field: 

from -40 to 105 °C (from -40 to 221 °F) 

 

Resolution: 

0.1 °C (1 °F). 

Digital inputs: 

1 dry contact (door switch/multi-purpose). 

Dry contact: 

Type of contact: 

5 VDC, 1.5 mA 

 

 

Power supply: 

none 

 

 

Protection: 

none. 

Digital outputs: 

3 electro-mechanical relays. 

K1 relay: 

SPST, 16 A res. @ 250 VAC 

K2 relay: 

SPDT, 8 A res. @ 250 VAC. 

K3 relay: 

SPST, 5 A res. @ 250 VAC. 

Type 1 or Type 2 actions: 

type 1. 

Additional features of Type 1 or Type 2 actions: 

C. 

 

Displays: 

custom display, 3 digit, with function icons. 

Alarm buzzer: 

built-in. 

Communications ports: 

1 TTL MODBUS slave port for BMS. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.B. 

The device must be disposed of according to local regulations governing the collection 

of electrical and electronic equipment. 

 

This document and the solutions contained therein are the intellectual property of EVCO and thus protected 

by the Italian Intellectual Property Rights Code (CPI). EVCO imposes an absolute ban on the full or partial 

reproduction and disclosure of the content other than with the express approval of EVCO. The customer 

(manufacturer,  installer  or  end  user)  assumes  all  responsibility  for  the  configuration  of  the  device. 

EVCO  accepts  no  liability  for  any  possible  errors in  this  document  and  reserves  the  right  to make  any 

changes at any time without prejudice to the essential functional and safety features of the equipment.

 

 

 

EVCO S.p.A. 

Via Feltre 81, 32036 Sedico (BL) ITALY 

Tel. +39 0437/8422 | Fax +39 0437/83648 

email [email protected] web www.evco.it

 