EVBIKE EVBAT36V13A Installation And Operation Manual Download Page 7

ERROR MESSAGES

Thanks to an intelligent circuit controlled by a microprocessor (so-called BMS) the ba

tt

ery can record many 

values and based on them evaluate di

erent risks. In case there is a risk of damaging the cells based on cri

ti

cal 

opera

ti

on values (high temperature, extremely high current) the ba

tt

ery is blocked for further use. In most 

cases it is 

fi

ne to leave the ba

tt

ery outside of the bracket and when the values are acceptable again the ba

tt

ery 

unblocks itself for further opera

ti

on. Typically it is an overheated ba

tt

ery due to direct sunshine or 

overcharging cells in the process of recupera

ti

on of braking energy to a fully charged ba

tt

ery.

While considering the above if it is s

ti

ll not possible to switch the ba

tt

ery on and normally use, please check 

the following messages using the status LEDs.

Meaning of the individual faults and possible solu

ti

ons:

www.EVBIKE.cz

Dovozce:

 Global World Logis

ti

c Ltd.,EU-VAT ID: CZ682998344

1

2

3

4

5

defec

ti

ve charger

deep discharge

defec

ti

ve cell

misbalanced cells

high load

LED4 (red)

-

-

-

-

fl

ashes

LED3 (green)

fl

ashes

-

-

-

fl

ashes

LED2 (green)

-

fl

ashes

-

fl

ashes

-

LED1 (green)

-

-

fl

ashes

fl

ashes

-

1

2

3

4

5

Defec

ti

ve charger or BMS module of the ba

tt

ery. Please try to replace the charger. If charging 

the ba

tt

ery is s

ti

ll impossible, contact a service.

Deeply discharged ba

tt

ery due to an improper maintenance by the user. It is necessary to store 

the ba

tt

ery charged to at least 75% of its capacity. Deep discharge may cause en

ti

re damage to 

the ba

tt

ery cells. Switch the ba

tt

ery o

 (the red and green LEDs 

fl

ash). Connect the charger and leave 

it connected for at least 3 hours. If charging does not start and the problem persist, contact an 
authorized service for diagnos

ti

cs and repair.

One or more cells are defec

ti

ve. Switch the ba

tt

ery o

 (the red and green LEDs 

fl

ash). Connect 

the charger and leave it connected for at least 3 hours. If charging does not start and the problem 
persist, contact an authorized service for repair.

The cells are misbalanced. Switch the ba

tt

ery o

 (the red and green LEDs 

fl

ash). Connect the charger 

and leave it connected for at least 3 hours. If charging does not start and the problem persist, contact 
an authorized service for repair.

Weak or defec

ti

ve cells. Excessive load of the ba

tt

ery – short circuit protec

ti

on. If in the course 

of 15 minutes BMS records more than 8 

ti

mes disconnec

ti

on due to overloading, then BMS reports 

an error. Please check the connec

ti

on of the ba

tt

ery and the cable of any breakage. Furthermore, 

check the system se

tti

ngs whether the recupera

ti

on (regenera

ti

on of the braking energy) is not 

ac

ti

ve and disable it if needed.

Summary of Contents for EVBAT36V13A

Page 1: ...Batteries for electric drive of bikes I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L EVBAT48V9A EVBAT36V13A EVBAT36V9A ...

Page 2: ...t you from using our product please contact your reseller for further discussion and keep the original packaging The reseller will advise you how to proceed properly www EVBIKE cz Dovozce Global World Logistic Ltd EU VAT ID CZ682998344 Table of Contents Product Specifications Installation before first time use Control Error Messages Using the Battery Safety Precautions and Instructions for the End...

Page 3: ...Without any memory effect Type of Samsung cells Number of cells Dimensions length x width x height Weight Type of battery case A typical capacity for an aggressive discharge of a permanent discharge current After 600 normal cycles i e discharge from 100 to 50 of the capacity the battery still has minimally 70 of its original capacity The dimensions and weight without the bracket EVBAT36V13A 36V 13A...

Page 4: ...ld today However these holes are on a different location on each frame Therefore first place the whole battery into the bike frame and think of a suitable location always keep in mind that the battery needs to be easily inserted and removed from the bike frame the distance between the frame and the battery edges should be lower than 20 mm from the bike frame fig 1 2 Drill the installation hole Dism...

Page 5: ...the battery cable to the motor control unit making sure you get the polarity right www EVBIKE cz Dovozce Global World Logistic Ltd EU VAT ID CZ682998344 5 7 6 1 2 3 4 LEDs of charge status indicator 1 Switching ON and OFF To activate the battery ON press button and hold it until the green charge status indicator LEDs LED 1 and 2 flash several times alternately To disable the battery OFF press butt...

Page 6: ...possible to take the key out During the ride and manipulation with the bike always remove the key in order to prevent from losing it or breaking it in the lock Upon ejecting the battery from the bracket please proceed in the following way In the unlocked position grasp the battery on its sides by both hands and by pressing forward towards the controls move the battery forward for about 10 mm Now t...

Page 7: ...eplace the charger If charging the battery is still impossible contact a service Deeply discharged battery due to an improper maintenance by the user It is necessary to store the battery charged to at least 75 of its capacity Deep discharge may cause entire damage to the battery cells Switch the battery off the red and green LEDs flash Connect the charger and leave it connected for at least 3 hours...

Page 8: ...ot be possible to recharge the battery Such damage can be easily diagnosed and faults resulting from such a behavior are excluded from warranty 3 Storage If you do not use your bike for over an hour the battery enters sleep mode It is not necessary to switch the battery off in everyday use It is only necessary to recharge it If you are not going to use your bike for longer than 48 hours always take...

Page 9: ...e website of the reseller 4 General rules for using and storing batteries www EVBIKE cz Dovozce Global World Logistic Ltd EU VAT ID CZ682998344 Danger of short circuit and subsequent fire Both charged and discharged cells contain a large amount of electric energy that may cause electric sparks or electric arc if the contacts are shorted The red hot contacts may ignite other flammable materials Dan...

Page 10: ...ren must not be allowed to replace the batteries without the supervision of an adult Do not encase or do any other modifications Encasement or any other modification to the battery may cause blockage of the safety ventilation mechanism Any modifications need to be consulted with the reseller Batteries that are not used need to be stored charged and kept out of reach of any metal subjects that coul...

Reviews: