ERROR MESSAGES
Thanks to an intelligent circuit controlled by a microprocessor (so-called BMS) the ba
tt
ery can record many
values and based on them evaluate di
ff
erent risks. In case there is a risk of damaging the cells based on cri
ti
cal
opera
ti
on values (high temperature, extremely high current) the ba
tt
ery is blocked for further use. In most
cases it is
fi
ne to leave the ba
tt
ery outside of the bracket and when the values are acceptable again the ba
tt
ery
unblocks itself for further opera
ti
on. Typically it is an overheated ba
tt
ery due to direct sunshine or
overcharging cells in the process of recupera
ti
on of braking energy to a fully charged ba
tt
ery.
While considering the above if it is s
ti
ll not possible to switch the ba
tt
ery on and normally use, please check
the following messages using the status LEDs.
Meaning of the individual faults and possible solu
ti
ons:
www.EVBIKE.cz
Dovozce:
Global World Logis
ti
c Ltd.,EU-VAT ID: CZ682998344
1
2
3
4
5
defec
ti
ve charger
deep discharge
defec
ti
ve cell
misbalanced cells
high load
LED4 (red)
-
-
-
-
fl
ashes
LED3 (green)
fl
ashes
-
-
-
fl
ashes
LED2 (green)
-
fl
ashes
-
fl
ashes
-
LED1 (green)
-
-
fl
ashes
fl
ashes
-
1
2
3
4
5
Defec
ti
ve charger or BMS module of the ba
tt
ery. Please try to replace the charger. If charging
the ba
tt
ery is s
ti
ll impossible, contact a service.
Deeply discharged ba
tt
ery due to an improper maintenance by the user. It is necessary to store
the ba
tt
ery charged to at least 75% of its capacity. Deep discharge may cause en
ti
re damage to
the ba
tt
ery cells. Switch the ba
tt
ery o
ff
(the red and green LEDs
fl
ash). Connect the charger and leave
it connected for at least 3 hours. If charging does not start and the problem persist, contact an
authorized service for diagnos
ti
cs and repair.
One or more cells are defec
ti
ve. Switch the ba
tt
ery o
ff
(the red and green LEDs
fl
ash). Connect
the charger and leave it connected for at least 3 hours. If charging does not start and the problem
persist, contact an authorized service for repair.
The cells are misbalanced. Switch the ba
tt
ery o
ff
(the red and green LEDs
fl
ash). Connect the charger
and leave it connected for at least 3 hours. If charging does not start and the problem persist, contact
an authorized service for repair.
Weak or defec
ti
ve cells. Excessive load of the ba
tt
ery – short circuit protec
ti
on. If in the course
of 15 minutes BMS records more than 8
ti
mes disconnec
ti
on due to overloading, then BMS reports
an error. Please check the connec
ti
on of the ba
tt
ery and the cable of any breakage. Furthermore,
check the system se
tti
ngs whether the recupera
ti
on (regenera
ti
on of the braking energy) is not
ac
ti
ve and disable it if needed.