background image

Introduction:

The ZW1505 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.

around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

ZW30 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.

Key Features:

 ---Remote ON/OFF control via the Z-Wave controller
 ---Manual ON/OFF control with the front panel push button
 ---Support Association Group and Auto Report switch status
 ---Support USB charging report
 ---Support firmware upgrades via Over-the-air (need Gateways support)

Key function description

  Function 1:    Press the button to turn the output ON or OFF
  Function 2:    Press the button three times quickly to ADD and REMOVE
  Function 3:    Press the button twice quickly and then press and hold the button 10S.device will reset
  Function 4:    Press the button three quickly and then press and hold the button 10S.change Parameter 26 value,
  Function 5:    Press the button six times quickly,change Parameter 27 value.

USB charging report

  Endpoint 6:   USB Charging output current, send basic report(0xFF)
  Endpoint 7:   USB is not Charging , send basic report(0x00)

Z-Wave Remote Control

ADD or Remove the ZW1505 from the existing Z-Wave home control network with your primary controller.
 ---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.

Include ZW1505 to/from a Z-Wave Gateway with supporting Security.The ZW1505 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by 
Z-WaveTM Controller means “Remove” or “Exclusion”.

z-wave protocol Command Class Node Info 

  

  COMMAND_CLASS_ZWAVEPLUS_INFO,
  COMMAND_CLASS_SWITCH_BINARY,
  COMMAND_CLASS_ASSOCIATION,

Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal

 ---When prompted by your primary controller, click the Up or Down button six times in one second.

  COMMAND_CLASS_ASSOCIATION,
  COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
  COMMAND_CLASS_ASSOCIATION_GRP_INFO,
  COMMAND_CLASS_TRANSPORT_SERVICE_V2,
  COMMAND_CLASS_VERSION,
  COMMAND_CLASS_MANUFACTURER_SPECIFIC,
  COMMAND_CLASS_DEVICE_RESET_LOCALLY,
  COMMAND_CLASS_POWERLEVEL,
  COMMAND_CLASS_CONFIGURATION,
  COMMAND_CLASS_NOTIFICATION_V8,
  COMMAND_CLASS_METER_V4,
  COMMAND_CLASS_SECURITY_2,
  COMMAND_CLASS_MULTI_CHANNEL_V4,
  COMMAND_CLASS_SUPERVISION
  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

The Below listed Command Class are all supported the Security S2

  COMMAND_CLASS_VERSION,
  COMMAND_CLASS_SWITCH_BINARY,
  COMMAND_CLASS_ASSOCIATION,
  COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
  COMMAND_CLASS_ASSOCIATION_GRP_INFO,
  COMMAND_CLASS_MULTI_CHANNEL_V3,
  COMMAND_CLASS_MANUFACTURER_SPECIFIC,
  COMMAND_CLASS_DEVICE_RESET_LOCALLY,
  COMMAND_CLASS_POWERLEVEL,
  COMMAND_CLASS_CONFIGURATION,
  COMMAND_CLASS_NOTIFICATION_V8,
  COMMAND_CLASS_METER_V4,
  COMMAND_CLASS_SUPERVISION
  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

Reviews: