EUTECH INSTRUMENTS ION 6 PLUS PH ION MV TEMP Instruction Manual Download Page 24

Instruction Manual 

                                                                                    pH 5+, pH 6+, Ion 6+ 

-20-

 

For more information on Eutech Instruments products, contact your nearest 
distributor or visit our website listed below:  

Eutech Instruments Pte Ltd.

 

Blk 55, Ayer Rajah Crescent, 
#04-16/24 Singapore 139949 
Tel: (65) 6778 6876 
Fax: (65) 6773 0836 
Email: [email protected] 
Website: www.eutechinst.com 

Distributed by: 

 

 

Summary of Contents for ION 6 PLUS PH ION MV TEMP

Page 1: ...Technology Made Easy Instruction Manual pH 5 pH Temp pH 6 pH mV Temp Ion 6 pH Ion mV Temp 68X243633 Rev 1 12 08 Part of Thermo Fisher Scientific...

Page 2: ......

Page 3: ...s as possible If there are doubts in the use of this meter please do not hesitate to contact the nearest Eutech Instruments Authorized Distributor Eutech Instruments will not accept any responsibility...

Page 4: ...ion 7 3 1 1 pH Calibration Procedure 7 3 1 2 Changing the pH Buffer Group 8 3 1 3 Resetting User Calibrated Values 9 3 2 Ion Calibration Ion 6 9 3 2 1 Ion Calibration Procedure 10 3 3 Millivolt mV Cal...

Page 5: ...and temperature o C The pH 6 and Ion 6 meters measure pH mV ORP and temperature Additionally the Ion 6 allows direct ion concentration measurement of various ions mono and divalent The mV mode is als...

Page 6: ...ter starts up in the mode that you last switched off from MODE INC Selects measurement mode for Ion mV pH and Temperature Increment button for mV calibration pH 6 only CAL Allows calibration for Ion p...

Page 7: ...y condition 2 3 Inserting Removing the Rubber Armor Stand 1 To remove meter from rubber armor push out from the bottom edges of meter until it is completely out of boot Ensure that cables of ISE pH el...

Page 8: ...until it locks 2 5 Battery Replacement The LO annunciator of the LCD alerts you when battery power is running low Caution Power off the meter before changing battery 2 6 Connecting the Electrode and...

Page 9: ...ey All LCD segments will display momentarily as the meter performs a self diagnostic test The Ion 6 will display if the meter has not been calibrated or if the meter has been reset 2 Press MODE key to...

Page 10: ...ue will not be accepted Press CAL to abort calibration and resume measurement Always use new pH buffer solutions for calibration Do not reuse buffer solutions as it may be contaminated and affect the...

Page 11: ...everting to pH measurement mode 6 For highest accuracy perform a multiple point calibration Repeat step 1 with additional pH buffer calibration standard solutions 3 1 2 Changing the pH Buffer Group Yo...

Page 12: ...ration Ion 6 The Ion 6 meter is capable of 2 or 3 point ion calibration with standard solutions The Ion 6 will display if the meter has not been calibrated or if the meter has been reset To abort ion...

Page 13: ...h calibration or sample measurement to avoid cross contamination 3 2 1 Ion Calibration Procedure The Ion 6 can measure various ions Ion measurement requires ion selective electrodes ISE sold separatel...

Page 14: ...ndard solution Add ISA if required Swirl it gently Press CAL key to begin calibration mode 6 Press ENTER to confirm that the ppm value is the desired standard The displayed value now shows the corresp...

Page 15: ...ss MODE key to enter mV mode the LCD displays mV 2 Dip the ORP electrode into a known standard solution e g Quinhydrone 255 and swirl it until the reading stabilizes 3 Press CAL key to enter mV calibr...

Page 16: ...displayed value to a NIST certified thermometer or other thermometer known to be accurate For best accuracy place both the probe and thermometer in a constant temperature bath 3 Press CAL key to enter...

Page 17: ...o a constant temperature bath 3 Press CAL key to enter temperature calibration mode The LCD shows CA momentarily and displayed reading flashes Note that this displayed value should either be 25 0 o C...

Page 18: ...ection 4 3 4 Rinse probes with clean water before taking next reading or storage 4 2 Millivolt mV Reference Check Ion 6 only The mV mode in Ion 6 can be used for the diagnosis of ISE or pH electrode c...

Page 19: ...have 2 point calibration Perform 2 or 3 point ion calibration LO displays in the LCD Low battery Replace batteries Unstable reading a Electrode not deep enough in sample b Dirty electrode c Broken ele...

Page 20: ...0 10 01 USA pH 4 01 6 86 9 18 NIST pH 4 10 6 97 Pb 3 3 3 Temperature Range 0 0 to 100 0 o C 3 3 3 Resolution 0 1 o C 3 3 3 Accuracy 0 5 o C 3 3 3 Temperature Comp Automatic Manual 0 to 100 o C 3 3 3 M...

Page 21: ...n 6 Meter with ATC probe ECPH5TEMP01P ECION601PLUS Ion 6 Meter with pH and ATC probes ECFC7252201B ECPH5TEMP01P and solutions in hard carrying case ECION602PLUSK Epoxy pH Combination Electrode Double...

Page 22: ...or inadequate maintenance by customer Unauthorized modification or misuse Operation outside of the environment specifications of the products 10 RETURN OF ITEMS Authorization must be obtained from ou...

Page 23: ......

Page 24: ...struments products contact your nearest distributor or visit our website listed below Eutech Instruments Pte Ltd Blk 55 Ayer Rajah Crescent 04 16 24 Singapore 139949 Tel 65 6778 6876 Fax 65 6773 0836...

Reviews: