The standard pump/compressor cannot start against vacuum/pressure. Contact Eurovacuum for an 
alternate vacuum pump/compressor designed to meet your demand. 
 
Improper disassembly or repair will damage the pump/compressor. Only qualified personnel should 
make repairs. 
The pump/compressor is maintenance-free. Do not lubricate any of the parts with oil, grease, or 
petroleum products nor clean with acids, caustics, or chlorinated solvents at any time as this will 
affect the lifetime of the unit. 

 

2.1 General Notices 
 

  - Understand fully this installation and operating manual before operation. 

  - 

The other person except authorized operator should not operate the pump/compressor. 

  - 

When the pump/compressor is not properly working, it should be stopped immediately. 

Eurovacuum shall have no liability for any accident and failure arising from no compliance with 

instructions in this manual. 
   

 
3.0 Warranty 
 

EVPP-Series vacuum pumps/compressors have a warranty of 12 months from the moment of the 
date of shipment. They are only valet when the pump/compressor has been properly installed and 
operated under normal conditions of use like mentioned inside this manual.

 

 
 
4.0 PROBLEM SOLVING 
 
4.1 Problem 
 

  Pump/compressor does not start.  
 

  4.1.1 Possible Cause 
 

    No main power supply. 

    Remedy 

check the main power supply and cables. 

 

  4.1.2 Possible Cause 
 

    Wrong voltage or frequency. 

Remedy 

: check the required voltage and frequency on the pump/compressor and order the 

correct pump/compressor for your supply power. 

 

  4.1.3 Possible Cause 
 

    Capacitor defective. 

    Remedy 

: Check capacitor and replace if necessary. 

 

  4.1.4 Possible Cause 
 

There is full vacuum (vacuum version) or full pressure (compressor version) in the pipe system or 
tank. 

Remedy 

: vent the system to atmospheric pressure and the pump/compressor will start again, if 

this happens more often than fit an check valve before the pump/compressor and the pipe system 
and/or tank.  

 
 
 
 
 
 

Summary of Contents for EVPP Series

Page 1: ...Eurovacuum Installations and Operating manual EVPP Series Vacuum pumps Dry piston vacuum pumps...

Page 2: ...um lifting Composite industry Medicinal technology Plastic production Wood industry Paint spray Basting Dust removal Advantages to the User Oil less non lube piston and cylinder Low noise level Perman...

Page 3: ...these operating instructions be read and understood prior to the installation and start up 1 0 INSTALLATION 1 1 Unpacking 1 2 Location 1 3 Electrical connection 2 0 OPERATION 2 1 General Notices 3 0...

Page 4: ...can be evenly supported on its rubber feet Leave 10 15 cm of access around the pump to allow proper cooling Also adequate ventilation must be provided for the fans radiator and motor 1 3 Electrical c...

Page 5: ...h instructions in this manual 3 0 Warranty EVPP Series vacuum pumps compressors have a warranty of 12 months from the moment of the date of shipment They are only valet when the pump compressor has be...

Page 6: ...se Plate valve defective Remedy replace the plate valve 4 2 5 Possible Cause Vacuum pressure gauge defective or inaccurate Remedy use another gauge to measure the vacuum pressure 4 2 6 Possible Cause...

Page 7: ...nsufficient Remedy provide for adequate ventilation with cool air 4 4 2 Possible Cause Ambient temperature is too high Remedy relocate the pump compressor to area where the ambient temperature is belo...

Page 8: ...Eurovacuum Head office Tel 31 0 348560060 Wilgenweg 19 B Fax 31 0 348560075 3421TV Oudewater info eurovacuum eu The Netherlands http www eurovacuum eu...

Reviews: