EIN

4. CONTROLS AND DISPLAY ELEMENTS

To enter the menu, press the 

MENU

 button. Use the PLUS/MINUS buttons to navigate through the menu.

In normal mode, you can set the temperature with 

PLUS

 and 

MINUS

PLUS

Increase temperature /

navigate through menu

MINUS

Decrease temperature /

navigate through menu

MENU

Get to the menu

OK/SET

Confirm

Key lock (S. 16) 

Self-Learning-Mode (S. 11)

Assembly/Disassembly (S. 8)

Fast-Link (S. 12)

Window-open-detection (S. 16)

Battery level

LED-Bargraph:

Menu items / Functions  

Manual Operation:

Use 

PLUS/MINUS

 to manually change the room temperature at any time. In AUTO mode, this manually set 

temperature remains until the next setting point. GENIUS LED 100 then switches back to the set heating pro-

gramme.

Summary of Contents for GENIUS LED100

Page 1: ...Eurotronic Technology GmbH S dweg 1 36396 Steinau Ulmbach Germany www eurotronic org THE INGENIOUS ENERGY SAVING CONTROLLER GENIUS INSTALLATION OPERATION GUIDE GENIUS LED100...

Page 2: ...11 6 3 Fast Link Technology 12 7 GENIUS App 13 7 1 Settings App 13 7 2 Temperature App 14 7 3 Heating Profile App 14 7 4 Holiday Function App 15 7 5 Support App 15 8 Further Functions 16 9 Cleaning a...

Page 3: ...dapter EIN GENIUS LED 100 Energy saving controller Screw for adapter When using the RAV adapter you need the RAV Pin for the extension of the valve stem RAV RA RAVL RAV Pin NOTE The following figures...

Page 4: ...Do not short circuit the batteries Never attempt to charge non rechargeable batteries Never disassemble batteries Do not use new and used batteries together Observe the correct polarity when insertin...

Page 5: ...100 GENIUS LED 100 is an energy saving controller for radiators equipped with Fast Link technology for modern and simple operation It regulates your room temperature automatically according to your s...

Page 6: ...INUS Decrease temperature navigate through menu MENU Get to the menu OK SET Confirm Key lock S 16 Self Learning Mode S 11 Assembly Disassembly S 8 Fast Link S 12 Window open detection S 16 Battery lev...

Page 7: ...1 2 Now insert the batteries Pay attention to the correct polarity Do not use rechargeable batteries 3 Place the battery cover back on the GENIUS LED 100 Fig 2 by pressing until it clicks 5 1 INSERTIN...

Page 8: ...stening and pull it off the valve Fig 3 2 If necessary select a suitable adapter and mount it on the valve Fig 4 3 Screw the thermostat onto the valve or adapter by turning the union nut clockwise Fig...

Page 9: ...Oventrop M30x1 0mm Meges M38x1 5mm Ondal M38x1 5mm Giacomini 22 6mm Rossweiner M33x2 0mm Markaryd M28x1 0mm Ista M32x1 0mm Vama M28x1 0mm Pettinaroli M28x1 5mm T A M28x1 5mm Gampper 1 2 6 Danfoss RA R...

Page 10: ...tation starts after confirmation The device now adapts to the stroke of your valve body To do this the valve is now opened and closed several times to learn the respective end points A running light i...

Page 11: ...using the PLUS and MINUS buttons The temperature is always increased or decreased in 1 5 steps To start the self learning function running time 24 hours select the menu item Self learning function in...

Page 12: ...n set the brightness of your display to the highest level No energy saving mode or similar must be activated 1 Remove the battery cover Fig 9 2 Press the MENU button on your controller Use PLUS MINUS...

Page 13: ...s you have made a change in the app Select the sensitivity of the temperature setting high medium low In the menu bar you can switch between the menu items settings temperature heating profile and hol...

Page 14: ...perature button and set the temperature using the setting Determine how far the temperature should be lowered during the saving times To do this select the Economy temperature button and set the tempe...

Page 15: ...day profile for the time of your absence Select the time of your return Determine the room tem perature for the duration of your absence After you have created your holiday profile transmit it via Fas...

Page 16: ...e automatically active Anti freeze function If the temperature drops below 8 C GENIUS LED 100 opens the valve until the temperature rises above 8 C again This prevents the radiators from freezing Anti...

Page 17: ...ress the OK button or perform adaptation of the device by removing and reinserting the batteries The endless thread now turns and tightens the thrust piece again Attach to radiator and perform adaptat...

Page 18: ...Weight 149 7 g incl batteries Degree of protection IP20 Degree of pollution 2 Technical modifications are subject to change All descriptions for compatibility are without engagement For technical sup...

Page 19: ...eclaration of Conformity Eurotronic Technology GmbH hereby declares that the GENIUS LED 100 radiator thermostat complies with all applicable European Economic Area regulations of Directive 2014 53 EU...

Page 20: ...Eurotronic Technology GmbH S dweg 1 36396 Steinau Ulmbach Germany www eurotronic org 08 2019...

Reviews: