EUROSTER 2006TXRXG Installation And Operation Manual Download Page 5

EUROSTER 2006TXRXG 

 INSTALLATION AND OPERATION MANUAL

 

5

 

 

f)

 

Repeat the sequence 

 and 

/

 to set the minutes. 

g)

 

After five seconds, the set-point is stored and the device resumes operation. 

MODIFYING TEMPERATURE LEVELS 

 comfort 

 and economical 

 

The temperatures programmed under 

 and 

 symbols are valid for all days of the week. 

a)

 

Turn the knob to the START position. 

b)

 

To enable the change of comfort temperature set-point, press 

 button. 

To enable the change of economical temperature set-point, press 

 button. 

c)

 

Having pressed 

 

or 

 button again, the displayed set-point value starts flashing. 

d)

 

Use 

 and 

 buttons to set the desired temperature. 

e)

 

After five seconds, the set-point is stored and the device resumes operation. 

 

 and 

 buttons are not active when the temporary temperature set-point (MANUAL) is 

active. Press HOLD twice to unlock them. 

ADJUSTING THE HYSTERESIS (ON/OFF DIFFERENCE) 

a)

 

Turn the knob to the START position. 

b)

 

Simultaneously press 

 and 

 buttons and hold them for 3 seconds. 

c)

 

While observing the display, use 

 or 

 

button to set the desired hysteresis of 0.4 

°C 

or 1 

°C.

 

d)

 

After five seconds, the set-point is stored and the device resumes operation. 

CORRECTING THE DISPLAYED TEMPERATURE 

a)

 

Turn the knob to the "PN" position. 

 

b)

 

Simultaneously press HOLD and 

 buttons and hold them for 3 seconds. 

c)

 

While  observing  the  display,  use 

 or 

 

buttons  to  adjust  the  temperature  display 

correction, from -2 

°C to +2

 

°C

 with the step of change of 0.2 

°C.

 

d)

 

After five seconds, the set-point is stored and the machine resumes operation. 

 SETTING PROGRAMS FOR INDIVIDUAL DAYS OF THE WEEK 

a)

 

Turn the knob to the day of the week you want to program (Wednesday is selected in 
the example shown in the figure). 

b)

 

The display will take the appearance as shown in the figure below: 

 

c)

 

Select  the  appropriate  period  using 

 or 

 buttons.  The  period  and  flashing 

 or 

 symbol will be displayed to facilitate the selection. 

d)

 

To  change  the  temperature  from 

 

to 

 press 

 or 

 button  respectively. 

Whenever  you  press 

 or 

 button  the  temperature  is  programmed  with  the  0.5-

hour-long period. 

Summary of Contents for 2006TXRXG

Page 1: ...ht temperature Each temperature is modifiable within the range of 5 C 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 48 temperature changes in 24 hours It is possible to program different time ranges for each day of the week 2 BASIC FUNCTIONS OF THE THERMOSTAT Does not require leading cable connections between the thermostat and the contro...

Page 2: ...kdays when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary temperature change MANUAL sign is displayed to indicate that the temperature has been changed manually by means of setting buttons 10 An icon indicating the activation and operation of the controlled device 11 Indication of the current time 12 Current weekday with 1 for Monday and 7 for Sund...

Page 3: ...d other liquids Do not install any unit showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to the failure of control systems The device is not intended for use by children Should there be any problem with the proper operation of the thermostat please contact your technician or the manufac...

Page 4: ...air sensor INSERTION AND REPLACEMENT OF BATTERIES Place the batteries in the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible when the battery voltage reaches the minimum allowable level It is recommended to replace the batteries with new alkaline batteries...

Page 5: ...ultaneously press and buttons and hold them for 3 seconds c While observing the display use or button to set the desired hysteresis of 0 4 C or 1 C d After five seconds the set point is stored and the device resumes operation CORRECTING THE DISPLAYED TEMPERATURE a Turn the knob to the PN position b Simultaneously press HOLD and buttons and hold them for 3 seconds c While observing the display use ...

Page 6: ...t on the thermostat maintains a constant user set temperature regardless of the programs e To return to operation with the program press the HOLD button 5 C FROST PROTECTION a Turn the knob to the START position b Press the HOLD button and hold it for 5 seconds The letters A F appear on the display c The frost protection function has been activated Regardless of the moment of its activation the fu...

Page 7: ... starts flashing in red and green alternately Insert the RX receiver into the mains socket Press the pairing button E on the receiver 3 times the blue LED lights up When the connection is established the blue LED on the receiver goes out If you use only one receiver press the button on the transmitter board the light goes out The pairing mode is ended If you are going to pair multiple receivers ma...

Page 8: ... Radio signal reception is indicated in green LED flashing three times stands for a very strong range twice for a strong range and once for sufficient range NO RADIO COMMUNICATION If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this condition lasts for 60 minutes no response from the receiver the receiver switches to the frost protection ...

Page 9: ...utput cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room In arrangement with a gas boiler 1 Electrical connection block 2 Output cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room MAINTENANCE Do not use solvents and aggressive detergents to clean the thermostat since they may damage the surface of the housing and the d...

Page 10: ... Hz socket Weight Thermostat without batteries 160 g receiver 340 g Warranty period 2 years Length of the receiver output cable 2 m The operating frequency of the set 868 MHz Maximum power of transmission of the thermostat and receiver 25 mW Thermostat class I Thermostat contribution to the seasonal energy efficiency of room heating 1 12 KIT CONTENTS a Euroster 2006TX thermostat b Euroster RXG rec...

Page 11: ... persons and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment and batteries Households play an important role in contributing to reuse and recovery including recycling of waste equipment The attitudes influencing protection of the common good of a clean environment are shaped at this level Hou...

Reviews: