EUROSTER 2006TXRXG
–
INSTALLATION AND OPERATION MANUAL
5
f)
Repeat the sequence
and
/
to set the minutes.
g)
After five seconds, the set-point is stored and the device resumes operation.
MODIFYING TEMPERATURE LEVELS
—
comfort
and economical
The temperatures programmed under
and
symbols are valid for all days of the week.
a)
Turn the knob to the START position.
b)
To enable the change of comfort temperature set-point, press
button.
To enable the change of economical temperature set-point, press
button.
c)
Having pressed
or
button again, the displayed set-point value starts flashing.
d)
Use
and
buttons to set the desired temperature.
e)
After five seconds, the set-point is stored and the device resumes operation.
and
buttons are not active when the temporary temperature set-point (MANUAL) is
active. Press HOLD twice to unlock them.
ADJUSTING THE HYSTERESIS (ON/OFF DIFFERENCE)
a)
Turn the knob to the START position.
b)
Simultaneously press
and
buttons and hold them for 3 seconds.
c)
While observing the display, use
or
button to set the desired hysteresis of 0.4
°C
or 1
°C.
d)
After five seconds, the set-point is stored and the device resumes operation.
CORRECTING THE DISPLAYED TEMPERATURE
a)
Turn the knob to the "PN" position.
b)
Simultaneously press HOLD and
buttons and hold them for 3 seconds.
c)
While observing the display, use
or
buttons to adjust the temperature display
correction, from -2
°C to +2
°C
with the step of change of 0.2
°C.
d)
After five seconds, the set-point is stored and the machine resumes operation.
SETTING PROGRAMS FOR INDIVIDUAL DAYS OF THE WEEK
a)
Turn the knob to the day of the week you want to program (Wednesday is selected in
the example shown in the figure).
b)
The display will take the appearance as shown in the figure below:
c)
Select the appropriate period using
or
buttons. The period and flashing
or
symbol will be displayed to facilitate the selection.
d)
To change the temperature from
to
press
or
button respectively.
Whenever you press
or
button the temperature is programmed with the 0.5-
hour-long period.