A DESCRIPTION OF THE DEVICE 

The Euroster 2006TXRXG wireless thermostat allows you to control the indoor temperature in a 
very  simple  and  efficient  way,  without  the  need  for  labor-intensive  wiring  between  the 
thermostat and the heating device. 
It is used to control the operation of  the CH boiler and other heating system components. It 
controls  electrical  equipment,  floor  heating,  and  air-conditioning  systems.  The  thermostat 
operates with two temperature levels: comfort (day 

) temperature and economical (night 

temperature. Each temperature is modifiable within the range of 5 

°C...35

 

°C. The thermostat 

is  programmable  in  seven-day  cycles  with  an  accuracy  of  0.5  hour,  therefore  it  enables  48 
temperature changes in 24 hours. It is possible to program different time ranges for each day 
of the week. 

2.

 

BASIC FUNCTIONS OF THE THERMOSTAT 

 

Does not require leading cable connections between the thermostat and the controlled 
device 

 

User-friendly thermostat enabling easy control of temperature in living and utility rooms 

 

Bidirectional  communication  ensures  high  operational  reliability  and  resistance  to 
interference 

 

Up to 6 RXG receivers can be used 

 

Radio signal strength information, 

 

Legible, backlit LCD 

 

Two temperature levels: comfortable and economical (for the entire week) 

 

Temperature setting with the accuracy of 0.2 

°C

 

 

Programming ranges with 0.5-hour accuracy 

 

Numerous  useful  functions:  temporary  temperature  setting,  constant  temperature, 
discharged batteries indication  

 

Temperature read-out accuracy of 0.1 

°C

 

 

Additional socket for connecting any network-powered device (up to 16 A) 

 

Temperature reading correction 

 

Surface mounting 

 

 

Summary of Contents for 2006TXRXG

Page 1: ...ht temperature Each temperature is modifiable within the range of 5 C 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 48 temperature changes in 24 hours It is possible to program different time ranges for each day of the week 2 BASIC FUNCTIONS OF THE THERMOSTAT Does not require leading cable connections between the thermostat and the contro...

Page 2: ...kdays when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary temperature change MANUAL sign is displayed to indicate that the temperature has been changed manually by means of setting buttons 10 An icon indicating the activation and operation of the controlled device 11 Indication of the current time 12 Current weekday with 1 for Monday and 7 for Sund...

Page 3: ...d other liquids Do not install any unit showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to the failure of control systems The device is not intended for use by children Should there be any problem with the proper operation of the thermostat please contact your technician or the manufac...

Page 4: ...air sensor INSERTION AND REPLACEMENT OF BATTERIES Place the batteries in the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible when the battery voltage reaches the minimum allowable level It is recommended to replace the batteries with new alkaline batteries...

Page 5: ...ultaneously press and buttons and hold them for 3 seconds c While observing the display use or button to set the desired hysteresis of 0 4 C or 1 C d After five seconds the set point is stored and the device resumes operation CORRECTING THE DISPLAYED TEMPERATURE a Turn the knob to the PN position b Simultaneously press HOLD and buttons and hold them for 3 seconds c While observing the display use ...

Page 6: ...t on the thermostat maintains a constant user set temperature regardless of the programs e To return to operation with the program press the HOLD button 5 C FROST PROTECTION a Turn the knob to the START position b Press the HOLD button and hold it for 5 seconds The letters A F appear on the display c The frost protection function has been activated Regardless of the moment of its activation the fu...

Page 7: ... starts flashing in red and green alternately Insert the RX receiver into the mains socket Press the pairing button E on the receiver 3 times the blue LED lights up When the connection is established the blue LED on the receiver goes out If you use only one receiver press the button on the transmitter board the light goes out The pairing mode is ended If you are going to pair multiple receivers ma...

Page 8: ... Radio signal reception is indicated in green LED flashing three times stands for a very strong range twice for a strong range and once for sufficient range NO RADIO COMMUNICATION If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this condition lasts for 60 minutes no response from the receiver the receiver switches to the frost protection ...

Page 9: ...utput cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room In arrangement with a gas boiler 1 Electrical connection block 2 Output cable using NO normally open mode 3 Euroster RXG receiver 4 Euroster TX placed in any room MAINTENANCE Do not use solvents and aggressive detergents to clean the thermostat since they may damage the surface of the housing and the d...

Page 10: ... Hz socket Weight Thermostat without batteries 160 g receiver 340 g Warranty period 2 years Length of the receiver output cable 2 m The operating frequency of the set 868 MHz Maximum power of transmission of the thermostat and receiver 25 mW Thermostat class I Thermostat contribution to the seasonal energy efficiency of room heating 1 12 KIT CONTENTS a Euroster 2006TX thermostat b Euroster RXG rec...

Page 11: ... persons and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment and batteries Households play an important role in contributing to reuse and recovery including recycling of waste equipment The attitudes influencing protection of the common good of a clean environment are shaped at this level Hou...

Reviews: