Resetting to Factory Defaults
If required the unit may be reset to factory defaults. It should be noted that if the engineer code
begins with a 9 it will not be defaulted.
1)
Remove all power from the system.
2)
Wait 10 seconds.
3)
Re-Apply power to the system.
4)
As soon as the display becomes active enter 1 4 7 No.
Changing Log Modes
The Eurosec CP8 LCD has two log modes. These are:-
a)
256 events without Time & Date stamps
or
b)
64 events with Time & Date stamps (Default setting)
To change the Log Mode:-
1)
Remove all power from the system.
2)
Wait 10 seconds.
3)
Re-Apply power to the system.
4)
As soon as the display becomes active enter 0 0 7 No. For 256 events.
or
As soon as the display becomes active enter 9 1 7 No. For 64 events.
Note:
When the Log Mode is changed the message ‘ L/ Rst ‘ will be added to the Log.
ENGINEER.qxd 16/10/01 13:14 Page 16