201902-348B-ENG 

User manual - DropPro 30P

P9

4. USE OF THE MACHINE 

4.1. PREREQUISITES

• 

The electric connection has to be 230 V - 16 A - 50 or 60 Hz with a 3 x 2,5 mm cable reel of 40m 

maximum, completely unreeled.

•  The machine must be coupled to a compressor.

•  After a prolonged standstill, the pump can be blocked. If that is the case, proceed by start and stop.Put 

some water and storage liquid in the tank and run the machine forward and backward for sequences of 
5 seconds. When the motor starts to turn normally, the pump is released. Empty the water in the tank.

• 

Check every month that the machine’s automatic lubricator (G) is working properly. The level of grease 

in the cartridge should decrease steadily. The absence of grease can seriously damage the machine.

4.2. STARTING UP

1.  Once the machine is connected, connect the air hose on the compressor.
2. 

Press the "ON/OFF" button (A), the warning light lights up.

3.  Remove the nozzle from the lance, then open the lance.
4. 

Set the flow-rate on 3 with the potentiometer (B).

5. 

Set the (C) button on "MANU" to check that the machine is working correctly. The drive shaft at the 

bottom of the tank shall turn.

6. 

Switch back the (C) button to the "AUTO" position.

7. 

Pour some product into the tank, then switch back the (C) button to "MANU" position.

8. 

Wait until the product flows regularly to the lance.

9. 

Switch back the (C) button to "AUTO" position.

10.  Close the lance and replace the nozzle.
11.  Connect the air hose to the lance.
12. 

Switch on the compressor*.

13.  When opening the lance, the machine starts running.
14.  Start spraying.

*NB: the compressor must be plugged in alone on a 16 A minimum plug with a 3 x 2,5 mm cable reel of 40m 
maximum, completely unreeled.

4.3. GRAIN SETTING

Large grain

High product flow-rate (to set from 1 to 10 with the potentiometer (B)).
Low air pressure (to set from 0 to 8 with the air regulator of the compressor).

Thin grain

Low product flow-rate.

High air pressure.

It is imperative to replace the automatic motor flange lubricator (G) every 6 months.

Summary of Contents for 30507

Page 1: ...90 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 DropPro 30P R f 30507 User manual Edition of...

Page 2: ...you just acquired EUROPE PROJECTION 228 avenue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 contact euromair com SUMMARY 1 USER MANUAL p 3 1 1 Importance of the manual p 3 1 2 Receivers of the...

Page 3: ...by the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the machine In case...

Page 4: ...water jet or flammable liquid on the machine Never direct an air jet or product jet on a person or an animal Do not touch warm surfaces of the equipment Always wear adequate body protections glasses...

Page 5: ...ell as children and animals In case of installation of the machine on scaffolding or a plan above ground level attach the machine to avoid any fall while operating Do not install the equipment on an i...

Page 6: ...entirely otherwise the equipment can be damaged The section must be proportional to the length of the cord 2 3 END OF LIFE OF THE PRODUCT At its end of life the machine must not be eliminated with the...

Page 7: ...o spray 3 2 TECHNICAL CHARACTERISTICS Product flow rate 0 to 26 kg min Motor power 2 2 kW Electrical supply 230 V Frequency 50 and 60 Hz Motor current 9 5 A Tank capacity 90 L Maximum grain size 3 mm...

Page 8: ...ropPro 30P 201902 348B ENG P8 3 YOUR MACHINE continued 3 3 IDENTIFICATION OF THE COMPONENTS A ON OFF buttton B Potentiometer C Manu Auto Reverse button D Emergency stop button E Rotor Stator F Drain v...

Page 9: ...ts up 3 Remove the nozzle from the lance then open the lance 4 Set the flow rate on 3 with the potentiometer B 5 Set the C button on MANU to check that the machine is working correctly The drive shaft...

Page 10: ...p 7 Turn the machine on to make the ball go through the hose until it comes out 8 Repeat operations 5 to 7 9 Stop the machine 10 Take off the connector on the pump again and flush out the pump nose 11...

Page 11: ...ector Check the compressor pressure After turning on the machine it does not run The machine has to be in automatic mode before it is turned on Unplug the machine to cut the electrical supply Wait for...

Page 12: ...User manual DropPro 30P 201902 348B ENG P12...

Page 13: ...ype Spraying machine Model DropPro 30P COMPLIES WITH THE DIRECTIVES Machines 2006 42 CE Low voltage 2014 35 UE CEM 2014 30 UE ROHS 2011 65 UE Noise emissions 2005 88 CE ROUSSET JANUARY 20th 2020 Patri...

Page 14: ...rs oils chains and quick release clip The warranty also excludes the equipment on which the serial number was erased or made illegible on which unauthorized people made attempts of repair which were t...

Page 15: ...ile number shall be given to the customer and an answer shall be provided within 48 working hours after reception provided that the request for warranty is considered as full In the event the equipmen...

Page 16: ...oy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 User manual DropPro 30P 201902 348B ENG...

Reviews: