Page
|
8
Number 9/10 /11/12– Room sensor 2
Room
sensor
2
is
arbitrary
to
install.
If
installed
it
can
adjust
the
set
heating
curve
for
heating
system
2
and
thereby
improve
system
efficiency.
However,
it
demands
a
central
place
in
the
building
in
order
to
function
well.
Number 13/14 – Temp sensor tank 1
Temp
sensor
tank
1
should
be
installed
in
tank
1.
Placing
is
of
great
importance
as
the
heat
pumps
will
operate
according
to
this
temperature.
Installation
in
a
is
recommended;
avoid
mounting
on
the
tank
shell.
Mount
the
sensor
somewhere
between
1/2
to
1/3
from
the
bottom,
see
picture
below.
Number 15/16 – Temp sensor tank 2
Temp
sensor
tank
2
should
be
installed
in
tank
2.
Placing
is
of
great
importance
as
both
the
heat
pumps
and
external
power
sources
will
operate
according
to
this
temperature.
Installation
in
a
is
recommended;
avoid
mounting
on
the
tank
shell.
If
electric
heaters
are
installed
the
sensor
must
be
placed
above
them.
Mount
the
sensor
somewhere
between
1/2
to
2/3
from
the
bottom,
see
picture
below.
Tank
1
Tank
2
Number 17/18 – Temp sensor heating system 1
Temp
sensor
tank
heating
system
1
should
be
installed
after
the
mixing
valve
controlling
heat
to
heating
system
1.
Mount
Mount
it
on
the
pipe
and
insulate
it
well.
Number 19/20 – Temp sensor heating system 2
Temp
sensor
tank
heating
system
1
should
be
installed
after
the
mixing
valve
controlling
heat
to
heating
system
2.
Mount
it
on
the
pipe
and
insulate
it
well.
Number 21/22 – Temp sensor heating system 3
Temp
sensor
tank
heating
system
1
should
be
installed
after
the
mixing
valve
controlling
heat
to
heating
system
3.
Mount
it
on
the
pipe
and
insulate
it
well.
Number 9/10 /11/12– Room sensor 2
Room
sensor
2
is
arbitrary
to
install.
If
installed
it
can
adjust
the
set
heating
curve
for
heating
system